120 – HI ECU Power Supply Voltage
ZKP-Number: 2.0140.931
Limit value 1
Cause
Corrective action
Supply voltage too high
1. Check Engine Control Unit supply voltage.
2. Contact Service.
121 – HIHI ECU Power Supply Voltage
ZKP-Number: 2.0140.932
Limit value 2
Cause
Corrective action
Supply voltage too high
1. Check Engine Control Unit supply voltage.
2. Contact Service.
122 – HI T-ECU
ZKP-Number: 2.0132.921
Limit value 1
Cause
Corrective action
Temperature in ECS too high
1. Reduce power.
2. Improve engine room ventilation.
141 – AL Power too high
ZKP-Number: 11.088.007
Cause
Corrective action
Alarm is tripped when average
power value has exceeded the
max. value defined in
PR1.1088.001 over the last
24 hours
u
Reduce power.
142 – AL MCR exceeded 1 hour
ZKP-Number: 1.1088.006
Cause
Corrective action
The MCR has been exceeded for
more than 1 hour within the last
12 hours
u
Reduce power.
148 | Troubleshooting | MS150093/05E 2018-12
TIM-ID: 0000008506 - 006