Temposonics
®
R-Series Powerlink V2
Operation Manual
I 14 I
4.4 Styles and installation of Temposonics
®
RD4
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 12: Temposonics
®
RD4 sensor electronics housings
Sensor electronics housing with bottom cable entry
45
(1.77)
2
(0.08)
Mounting block
45
(1.77)
Sensor electronics housing
123
(4.84)
Sensor electronics
housing
18
(0.71)
24.7
(0.97)
26.5
(1.04)
7.7
(0.3)
Ø 6.2
(Ø 0.24)
Ø 19
(Ø 0.75)
49
(1.93)
25
(0.98)
41
(1.61)
50
(1.97)
38
(1.5)
Recommendation:
Use M6×45 (ISO 4762)
screws for sensor fastening.
Fastening torque: 6 Nm.
Sensor electronics housing with side cable entry
5
(0.2)
Mounting block
45
(1.77)
Sensor electronics housing
123
(4.84)
18
(0.71)
24.7
(0.97)
24.7
(0.97)
8.2
(0.32)
7.7
(0.39
Ø 6.2
(Ø 0.24)
49
(1.93)
41
(1.61)
45
(1.77)
Ø 18
(Ø 0.71)
45
(1.77)
38
(1.5)
Sensor electronics
housing
Recommendation:
Use M6×45 (ISO 4762)
screws for sensor fastening.
Fastening torque: 6 Nm.