Parameter
description
Parameter value
Product name
Cordless impact wrench
Model
MSW-CIW18VL
MSW-CIW18V
Battery type
lithium-ion 18
V 1500mAh
lithium-ion
18V 1300mAh
Voltage [V~]/
frequency[Hz]
of battery
charger power
supply
230/50
Rotational
speed (no load)
[rpm]
0÷2200
0÷2500
Hits
[beats/min]
0÷2700
0÷3000
Maximum
torque [Nm]
240
110
Tool drive
hexagonal 1/2''
hexagonal 1/4''
Vibration
emission value
<2,5 m/s
2
Dimensions
HxWxD [mm]
225x90x215
155x74x210
TECHNICAL DATA
The product satisfies the relevant safety
standards.
Read the instructions before use.
The product must be recycled.
Use ear protection. Exposure to loud noises may
result in hearing loss.
1. GENERAL DESCRIPTION
The user manual is designed to assist in the safe and
trouble-free use of the device. The product is designed
and manufactured in accordance with strict technical
guidelines, using state-of-the-art technologies and
components. Additionally, it is produced in compliance
with the most stringent quality standards.
DO NOT USE THE DEVICE UNLESS YOU HAVE
THOROUGHLY READ AND UNDERSTOOD THIS
USER MANUAL.
To increase the product life of the device and to ensure
a trouble-free operation, use it in accordance with this user
manual and regularly perform the maintenance tasks. The
technical data and specifications in this user manual are
up to date. The manufacturer reserves the right to make
changes associated with quality improvement. Taking
into account technological progress and noise reduction
opportunities, the device was designed to reduce noise
emission risks to the minimum.
Legend
PLEASE NOTE!
Drawings in this manual are for
illustration purposes only and in some details may
differ from the actual machine.
The original operation manual is in German. Other
language versions are translations from German.
2. Usage safety
Electrical equipment:
ATTENTION!
Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in an electric shock, fire and/
or serious injury or even death.
Whenever "device" or "product" are used in the warnings
and instructions, it shall mean < Cordless impact wrench.
Do not use in very humid environments or in the direct
vicinity of water tanks. Prevent the device from getting wet.
Risk of electric shock! Do not cover air inlets/outlets. When
in use, do not put your hands or other items inside the
device!
3.1 Electrical safety
Applicable to the battery charger:
a)
The plug has to fit the socket. Do not modify the
plug in any way. Using original plugs and matching
sockets reduces the risk of electric shock.
b) Avoid touching earthed elements such as pipes,
heaters, boilers and fridges. There is an increased risk
of electric shock if the earthed device is exposed to
rain, in direct contact with a wet surface or operating
in a humid environment. Water ingression into the
device increases the risk of damage to the device and
of electric shock.
c)
Use the cable only in accordance with its designated
use. Never use it to carry the device or to pull the
plug out of a socket. Keep the cable away from heat
sources, oil, sharp edges or moving parts. Damaged
or tangled cables increase the risk of electric shock.
d)
If working with the device outside, make sure to use
an extension lead suitable for external use. Using an
extension lead suitable for external use reduces the
risk of electric shock.
e)
If using the device in a humid environment cannot
be avoided, a residual current device (RCD) should
be applied. The use of an RCD reduces the risk of
electric shock.
3.2 Safety at the workplace
a) Make sure the workplace is orderly and well lit.
A messy or poorly lit workplace may lead to accidents.
Try to anticipate what may happen, observe what is
going on and use common sense when working with
the device.
b)
Do not use the device in an explosion hazard zone,
for example in the presence of flammable liquids,
gasses or dust. The device generates sparks which
may ignite dust or fumes.
c) Upon discovering damage or irregular operation,
immediately switch the device off and report it to
a supervisor without delay.
d)
If there are any doubts as to the correct operation
of the device, contact the manufacturer's support
service.
e)
Only the manufacturer's service point may repair the
device. Do not attempt any repairs independently!
f)
If a fire starts, use solely powder or carbon dioxide
(CO
2
) fire extinguishers suitable for use on live
devices to put it out.
g) Children or unauthorised persons are forbidden
from entering a work station. (A distraction may
result in a loss of control over the device).
REMEMBER!
When using the device, protect children
and other bystanders.
3.3 Personal safety
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which
can significantly impair the ability to operate the
device.
b)
When working with the device, use common sense
and stay alert. Temporary loss of concentration
whilst using the device may lead to serious injuries.
c) Use personal protection equipment as required
for working with the device, specified in section 1
(Legend). The use of correct, approved personal
protection equipment reduces the risk of suffering
an injury.
d)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
e)
Do not overestimate your abilities. When using the
device keep your balance and remain stable at all
times. This will ensure better control over the device
in unexpected situations.
f)
Do not wear loose clothing or jewellery. Keep hair,
clothes and gloves away from moving parts. Loose
clothing, jewellery or long hair may get caught in
moving parts.
g) Remove all adjusting tools or spanners before
turning the device on. A tool or spanner left in the
revolving part of the device may cause injury.
3.4 Safe device use
a)
Do not overload the device. Use appropriate tools
for the given task. A correctly selected device will
perform the task for which it was designed better
and in a safer manner.
b)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and have to be repaired.
c)
When not in use, store in a safe place, away from
children and people not familiar with the device, who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
d)
Maintain the device in a good technical state. Before
each use check for general damage and especially
check for cracked parts or elements and for any other
conditions which may impact the safe operation of
the device. If damage is discovered, hand over the
device for repair before use.
e)
Keep the device out of the reach of children.
f)
Device repair or maintenance should be carried out
by qualified persons, only using original spare parts.
This will ensure safe use.
g)
To ensure the operational integrity of the device, do
not remove factory fitted guards and do not loosen
any screws.
h)
When transporting and handling the device between
the warehouse and the destination, take into account
the occupational health and safety principles for
manual transport operations which apply in the
country where the device will be used.
i)
Avoid situations where the device halts during
use due to excessive loading. This may result in
overheating of the drive elements and device
damage.
j)
Do not touch articulated parts or accessories, unless
the device has been disconnected from a power
source.
k)
Use insulated handles to grip the device. Make sure
that the metal tools attached to the device do not
come into contact with a live wire. Risk of electric
shock.
l)
The specified vibrations emission was measured
using standard measurement methods. Vibrations
emissions may change if the device is used in
different surroundings.
4. Use guidelines
The cordless impact wrench is designed to screw in, tighten
and unscrew bolts, screws, nuts etc. attachment elements.
The user is liable for any damage resulting from non-
intended uses of the device!
4.1 Device description
MSW-CIW18VL
MSW-CIW18V
8
7
6
5
2
1
4
3
9
8
7
6
5
1
2
4
3
1.
Direction switch
2. Handle
3. Battery
4.
Battery lock button
5.
On/Off trigger
6.
Battery charge status lights
7.
LED illumination
8.
Tool drive
9. Socket
4.2 Preparing for use
Battery charging
Attention: To connect/disconnect the battery, make sure
the device is off.
•
Press the lock button (4) and slide the battery out of
the device.
•
Connect the charger to a power source.
•
Connect the battery to the charger. A red light on the
charger will come on. The charger may be warm and
emit a buzzing sound. This is normal and does not
indicate incorrect operation.
•
Once the battery is fully charged, a green light on the
charger will come on. Disconnect the charger from
the power source and reinsert the battery into the
device.
Tool attachment
•
Before attaching/removing a work tool, ensure the
device is switched off.
U S E R M A N U A L
6
7
Rev. 06.03.2018
Rev. 06.03.2018