Page 74 MSI-3750CS-5 RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
combined with the standard computer commands. The preferred way to get data from the 3750CS is to use the
“CD” command, set up a print string with all the @ codes desired, then use the “PR” command to cause a data
Auto Off
AO
1=Disabled
2= 10 min.
3= 30 min.
4= 1 hour
5= 2 hours
6= 4 hours
7= 8 hours
8= 24 hours
Once the scale is off, the compute will not
be able to talk to it unless the Clock Mode is
enabled
Back Light
BL
1= Automatic
2= On
3= Off
Comm Port
Data
CD
Up to 480 char-
acters including
@ Codes
Send CD followed by all ‘@’ co text.
Must be terminated with a semicolon (;).
Total Mode
EM 1= Disabled
2= Autoload
3= Autonorm
4= Autopeak
5= OnAccept
6= Manual
7= Loaddrop
Filter
FL
1= Low Filter
2= Medium
3= High
B a r G r a p h
100% value
GH
Enter value = to 100% in current
weight units
Terminate value with any command or a
semicolon.
Bar Graph 0%
value
GZ
Enter value = to 0% in current weight
units
Terminate value with any command or a
semicolon.
B a r G r a p h
Mode
GM 1= Disabled
2= Per Cent
3= RF Modem
ID?
ID
Enter value = to 0% in current weight
units
Terminate value with any command or a
semicolon.
ID Code Dis-
play mode
IL
1= Disabled
2= Normal
3= Per Cent
ID Name
IN
Input up to an 8 character name
End with a ; if name is less than 8 characters.
ID String
IS
1= ID String 1
2= ID String 2
add text
Example: IS1This is a test; Terminate
with a ;
Keyboard
Enable
KE
1= Disabled
2= Enabled
Careful–disables all front panel switches.
Keyboard Func-
tion Emulate
KF
1= Power Off
2= Zero
3= Gross
4= Net
5= Tare
6= Total
7= View Total
8= Clear Last ∑
9= Clear ∑
10=Clear all ∑
11= Print
12= Pk Hld on
13= Pk Hld off
Terminate command with other command or
a “;”.
Turn on the
Power
O
None
Clock mode must be enable with seconds.
Delay at least 200 ms before sending additional
data.