MSA DR-209M Скачать руководство пользователя страница 1

“NPK Morsvyazavtomatica” LLC”

 

 

 

26E, Kibalchicha Str., St Petersburg                                   Tel.: 8 (800) 100-67-19                                                         [email protected] 
Russia, 192174                                                                   Fax: +7 (812) 362-76-36                                                      www.unicont.com 

 
 
 
 
 
 
 
 

 
 

 

Universal digital repeater 

DR-209M 

 

Operating manual 

 

 
 

 

 

Содержание DR-209M

Страница 1: ...NPK Morsvyazavtomatica LLC 26E Kibalchicha Str St Petersburg Tel 8 800 100 67 19 info unicont com Russia 192174 Fax 7 812 362 76 36 www unicont com Universal digital repeater DR 209M Operating manual...

Страница 2: ...ling 6 1 6 Packaging 6 2 INTENDED USE OF THE PRODUCT 8 2 1 Operational constraints 8 2 2 Usage preparations 8 2 3 Usage of the Product 9 3 TECHNICAL SERVICE 37 3 1 General instructions 37 3 2 Safety f...

Страница 3: ...instructions given in this document the safety regulations and rules applicable in the field shall be observed Only those who have had general education in the area of electronic devices and those who...

Страница 4: ...tting time intervals to monitor parameters for graph mode setting a data filter to output averaged values for the given time interval display of the required parameters from the received ones in full...

Страница 5: ...sing a front frame aluminum a rear panel steel a port to connect power cable and RS 422 serial interface ports to connect communication cables are located on the rear side under the protective cover C...

Страница 6: ...ing the relevant operation mode Caution LCD monitor with touch panel of resistive type surface touch layer is intended for application only with blunt smooth instruments Sharp instruments writing pen...

Страница 7: ...TS Name and identifier of consumables Weight of consumables Note Cleaning cloth 0 10 kg 1 To clean surfaces and parts of the system use clean cloth 2 To clean severe contami nation use alcohol soaked...

Страница 8: ...efore using the Product ensure the following steps a train staff to use the Product and checkout equipment as well as occupational safety applicable in the field b use only standard fuses c follow Rul...

Страница 9: ...Table 11 The Product in the operation mode can be used as a gyrocompass repeater b log repeater c depth finder repeater d inclinometer repeater e weather sensor or wind sensor transducer repeater f o...

Страница 10: ...ll screen mode single parameter displayed on the whole screen and in multi screen mode using a random pattern simultaneous output of up to 9 screens with various layout on the monitor Several possible...

Страница 11: ...the front panel Since the Product is equipped with a touch screen the screens can be changed by swiping to the left right The screens can be also changed by pressing touch buttons 1 2 10 on the pop up...

Страница 12: ...Operating manual Page 12 Figure 5 Structure of the configuration menu...

Страница 13: ...ostic check of ports operability System settings Settings up current time OS update screen calibration and operation in the service mode 2 3 7 Data display modes Received data are displayed on the LCD...

Страница 14: ...e digital mode Parameter Description Parameter Description Humidity absolute Depth sensor relative keel Amplitude STBD surface PORT Pitch roll Speed wind Pressure atmospheric true Heave heave relative...

Страница 15: ...position to destination true true present position to destination magnetic Time remaining Roll period Time zone Range to destination Cross track error Total distance travelled in the water Depth below...

Страница 16: ...displayed in different views 2 and serve to change scale calibration in the operation mode For more information on screen settings in graph mode see cl 2 3 12 2 Figure 8 Sample of graph 2 3 8 Setting...

Страница 17: ...on mode Time to GPS To set up GMT time by data received from a satellite Filters To switch on a filter for average value output of the required pa rameter Time zone To select a time zone world coordin...

Страница 18: ...lter list Name Function To confirm the select Cancel To cancel the selected settings To add a filter To delete all filters Time intervals to average values of the given parameter shall be entered into...

Страница 19: ...Time zone parameter allows for setting local ship time relative to UTC GMT received in NMEA sentences if Time to GPS is switched on Coordinate system parameter sets up a coordinate system WGS 84 42 9...

Страница 20: ...ive of specified herein parameter speed vessel is measured respective of ground or water Activation condition Pop up message speed vessel higher lower within range out of range Lower Specification of...

Страница 21: ...on the port Heel angle warning Warning of critical pitch Critical pitch on the bow Critical pitch at the stern Warning of critical level of the heave Critical level of the heave Surfacing Warning of v...

Страница 22: ...es settings of measurement units and data cor rection The structure is shown in Figure 12 Measurement units can be set by selecting a relevant option from the drop down list for each specified paramet...

Страница 23: ...Heel Pitch Heave To confirm the select Apply To apply the selected settings Cancel To cancel the selected settings Along with the settings of measurement units in this tab a user can also set up the...

Страница 24: ...of Displays tab page is represented in Figure 16 The following con trols are located on Displays tab page see Table 14 Table 14 The controls of Displays tab page Name Function 0 1 2 3 4 5 6 7 8 9 10 B...

Страница 25: ...out Screen setup The required parameters can be displayed on the screen in full screen mode and in multi screen mode Each of available screens can be split into 9 segments The user can select a pat te...

Страница 26: ...tern press and select a relevant icon from the drop down list se Figure 17 Then press button after the select Note Not all display modes and not all data types are available for every pattern 2 3 12 2...

Страница 27: ...ck to Screen setup To drop down list Data source Repeated click transfers to data source settings Graph mode Graphic mode Digital mode Mode without indicator 2 3 12 3 Select of displayed data types Se...

Страница 28: ...order of sentences transmission can be also configured data of Primary or Second ary source are received and processed as a primary value If data are received from the Primary source Secondary then P...

Страница 29: ...nto set number of divisions To confirm the select Cancel To cancel the selected settings Back to Screen setup To confirm the select of data source settings The description of indicator settings in Gra...

Страница 30: ...ndicator settings in Digital data display mode Name Function Primary To display data from the Primary source Secondary To display data from the Secondary source Primary then Secondary To set a status...

Страница 31: ...to configure reception transmission of data for each port to set parameters of NMEA sentences received by each port as well as to provide individual settings for each port baud rate stop bits parity t...

Страница 32: ...NMEA sentences press To configure selec tive data reception press Using this button the user can remove all NMEA sen tences which are excluded from selective data reception or transmission To remove...

Страница 33: ...controls of Settings suggestions Name Function To confirm the select Cancel To cancel the selected settings Transmitter index To set a transmitter index NMEA sentence To select NMEA sentence out of dr...

Страница 34: ...ondary source put a tick in a drop down list opposite 2 Provide these steps for all parameters If a selected NMEA parameter shall be excluded from the sentence put a tick opposite and the parameter wi...

Страница 35: ...d recommended for application on stations with low level of responsibility To display data received from the inclinometer a user shall select Inclinometer in drop down list of NMEA sentences To set up...

Страница 36: ...touch screen calibration and install OS update The current version of OS is repre sented in this tab page Figure 28 System tab page The controls of System tab page are represented in Table 25 Table 2...

Страница 37: ...unning equipment TS 2 shall be organized and controlled by a person in charge and provided by the staff on the running equipment 3 2 SAFETY FEATURES While maintaining the TS observe cl 4 2 3 3 MAINTEN...

Страница 38: ...iquid directly onto the screen 4 If varnish paint coating is damaged polish it with sand paper then clean with alcohol soaked cloth cover with varnish and dry up 1 person 5 minutes Check reliability o...

Страница 39: ...activate the screen menu open tab page Rx and check the reception transmission of NMEA sentences and compliance of received and trans mitted data by three ports with the settings 1 person 15 minutes 3...

Страница 40: ...ications in the area of the occupational safety Check grounding of the PSU before providing any repair works It is PROHIBITED to put a poster DO NOT switch on Under Operation when power supply switch...

Страница 41: ...sary Low image brightness Adjust screen backlight brightness No data is displayed No connection with signal source Check the data reception from the source Rx tab page Check the cable integrity and R...

Страница 42: ...ions 5 40 with the concentration of dust oil moisture and aggres sive impurities in the air within the required limits for the working areas of production facilities After storage or transportation of...

Страница 43: ...tion in sealed and heated compartments sea transportation in dry service premises The units must be transported in compliance with transportation rules applicable for each means of transport During lo...

Страница 44: ...nd an overage equipment unit to the manufacturer for its further disposal Proper disposal of Product components allows avoiding possible negative envi ronmental and health impacts and it also allows f...

Страница 45: ...In case of misuse of equipment the Manufacturer shall not accept damage claims For more warranty details visit our website www unicont com section Support Address and contacts of Manufacturer s servi...

Страница 46: ...oint true dg Heading to steer to destination waypoint magnetic dg BRG Brightness BWC Time UTC Destination latitude Destination longitude Bearing present position to destination true dg Bearing present...

Страница 47: ...km fathom ft mile mile st inch GGA Latitude Longitude Time UTC Number of satellites GLL Latitude Longitude Time UTC HDG Heading magnetic dg Heading true dg HDM Heading magnetic dg HDT Heading true dg...

Страница 48: ...knots m s km h mph mph st Track made good true dg Track made good magnetic dg RMB Cross track error m km fathom ft mile mile st inch Origin waypoint id m Destination waypoint id m Destination latitud...

Страница 49: ...distance travelled in the water m km fathom ft mile mile st inch Distance travelled in the water m km fathom ft mile mile st inch VTG Track made good true dg Track made good magnetic dg Ground speed...

Страница 50: ...le Roll period Amplitude PORT Amplitude STBD EL6 Major semi axis ellipse of errors m Minor semi axis ellipse of errors m The angle of rotation of the ellipse errors dg EL0 Ellipsoid Longitudinal speed...