US
MSA
TECHNICAL SPECIFICATIONS/CERTIFICATIONS
ALTAIR 5 - Operating Manual
53
Sensor
Min. alarm
setpoint
Max. alarm
setpoint
Default
calibration
values
COMB
5% LEL
60% LEL
58% LEL
CO
20 ppm
950 ppm
60 ppm
CO
2
/ MB 0-5 % Vol
0.20 % Vol
5.00 % Vol
CO
2
/ MB 0-10 % Vol
0.20 % Vol
8.00 % Vol
H
2
S
5 ppm
175 ppm
20 ppm
O
2
5.0%
24%
15.0%
SO
2
2.0 ppm
17.5 ppm
10.0 ppm
NO
2
2.0 ppm
17.5 ppm
10.0 ppm
NH
3
15 ppm
75 ppm
25 ppm
PH
3
0.3 ppm
3.75 ppm
0.50 ppm
Cl
2
0.5 ppm
17.5 ppm
10.0 ppm
ClO
2
0.1 ppm
0.9 ppm
0.8 ppm
HCN
4.5 ppm
20.0 ppm
10.0 ppm
EX sensors
Min
Max
IR Propane (LEL)
9 % LEL
80 % LEL
IR Butane (LEL)
9 % LEL
80 % LEL
IR Methane (25 % Vol)
1)
2.5 % Vol
25 % Vol
IR Propane (25 % Vol)
1)
5.0 % Vol
25 % Vol
IR Butane (25 % Vol)
1)
5.0 % Vol
25 % Vol
1) No alarm thresholds are adjustable for the IR sensors methane, propane and
butane in the measurement range 0 to 100 Vol. %.
This instrument is not approved for use in atmospheres containing >21 %
oxygen.
Содержание altair 5
Страница 59: ...US MSA ORDER INFORMATION ALTAIR 5 Operating Manual 59 Replacement parts 8 1 7 11 2 5 6 3 4 12 10 9 ...
Страница 73: ...US MSA APPENDIX FLOW CHARTS ALTAIR 5 Operating Manual 73 ...
Страница 133: ...ES INFORMACIÓN DE PEDIDOS MSA 60 ALTAIR 5 Manual de funcionamiento Piezas de repuesto 8 1 7 11 2 5 6 3 4 12 10 9 ...
Страница 147: ...ES APÉNDICE DIAGRAMAS MSA 74 ALTAIR 5 Manual de funcionamiento ...
Страница 207: ...FR INFORMATIONS POUR LES COMMANDES MSA 60 ALTAIR 5 Manuel d utilisation Pièces de rechange 8 1 7 11 2 5 6 3 4 12 10 9 ...
Страница 221: ...FR MSA 74 ALTAIR 5 Manuel d utilisation ...