Water Purification System Instruction Manual
2 / 11
3.
Master-S UVF Water Flow Chart
4.
Working Environments
Inlet water:
Tap water (TDS<200ppm will be suggested).
If inlet water TDS>200ppm, pretreatment is recommended. Water with higher TDS will affect
the quality of outlet water and life of purification cartridge.
Work temperature:
5-45
℃
Pressure:
1.0-4.0Kgf/cm
2
Power:
220V/50Hz,120W
【
Clean, dry working environments would be suggested!
】
5.
Installation Step
The purification system should be installed horizontally and near to tap water.
Tube installation and drag
The adapter of the machine is high quality easy-put adapter.
Proper usage is as follows:
Connect the tube:
press the oval cap of the interface strongly, then insert the tube to the bottom of
adapter.
Take off the tube:
press the oval cap of the interface strongly, then drag out the tube. Do not drag when
the tube can not be dragged out any more.
Tube installation and drag
All cartridges have been installed in the factory. Additional cartridges installation is unnecessary.
Check the accessory box. According to the “instaIlation guide chart” in the instruction manual, install the
machine with the adapters, tube and pretreatment filters(optional) in the accessory box. Connect with
the water tank, electrical source and tap water. At the end, turn on the power switch and the tap water
source valve, then the machine will produce pure water.