Section III
Operation
006-0007207 MPC-1250DC Guide
Rev F
26 of 44
03/03/2022
Operating Environment
The SynQor MPC‑1250 DC Output Series is designed for the extreme environmental conditions
of military and aerospace applications. All the electronic circuitry is contained in a sealed,
weather‑proof, shock‑proof chamber constructed of die‑cast aluminum. Only the redundant,
water‑proof cooling fans are exposed to the environment. The MPC will shut down if it is too hot.
The MPC (with cables connected or connector covers installed) has been qualified to the following
requirements of MIL‑STD‑810G:
MIL-STD-810G
Test Method
Name
Procedure
Details
500.5
Low Pressure
I, II and III
▪ 15,000 ft. operating
▪ 40,000 ft. storage
501.5
High Temperature
I and II
▪ +55
o
C operating
▪ +65
o
C storage
502.5
Low Temperature
I and II
▪ ‑20
o
C operating
▪ ‑40
o
C storage
503.5
Temperature Shock
I
▪ 10 cycles; >10
o
C/minute
506.5
Rain
I
▪ 4” rain/hour
▪ 40 mph wind velocity
507.5
Humidity
NA
▪ >95%
508.6
Fungus
NA
▪ 28 day test
509.5
Salt Fog
NA
▪ 5% salt solution
▪ 2 cycles (24 hr wet/24 hr dry)
510.5
Sand and Dust
I and II
▪ 20 mph blowing dust
▪ 40 mph blowing sand
514.6
Vibration
Category 5
▪ 5Hz (300 RPM)
▪ Loose Cargo
514.6
Vibration
Category 7
▪ General Exposure
514.6
Vibration
Category 8
▪ C‑130 Aircraft level
514.6
Vibration
Category 9
▪ General Exposure
514.6
Vibration
Category 24
▪ PSD = 0.04 g
2
/Hz; 20‑2000 Hz
▪ Operating
516.6
Shock
I, IV and VI
▪ 20 g/20 ms; 40 g/11 ms; 75 g/6 ms
▪ 48 inch drop in transit case
▪ 30 degree tilt and drop
528
Mechanical Vibrations of
Shipboard Equipment
I
▪ Operating