MOZELT GmbH & Co. KG
Load lifting magnet devices
Technical manual:
CoolGen 4
Copyright:
MOZELT GmbH & Co. KG, D-47269 Duisburg
Edition:
August 2014
Rev.:
00
Page 9
English
English
3.
Assembling
3.1
Assembling instructions
3.2
Installation of „BELL CLUTCH“ Coupling
Table of distances coupling halves
1
2
3
5
6
7
8
5
8
4
Generator type
Hydraulic motor
Distance A
Distance B
T4002 / CG4 13 kW
Bosch-Rexroth 16 ccm / Sunfab 17 ccm
0 mm
0 mm
T4002 / CG4 13 kW
Bosch-Rexroth 23 ccm / Sunfab 25 ccm
12 mm
12 mm
T4002 / CG4 20 kW
Bosch-Rexroth 23 ccm / Sunfab 25 ccm
11 mm
0 mm
1
2
3
4
Hydraulic motor
Adaptor ring for 16/17 ccm hydraulic motors
Clutch bell
Cover for speed measurement
6
7
8
9
Clamping bushing on the hydraulic motor
Coupling spider
Clamping bushing on the power generator
Shaft / end shield on the power generator
5
Coupling half
Fig.: 4 | Explosion drawing „BELL CLUTCH“ coupling
Fig.: 5 |
Distance drawing coupling halves
1
CAUTION
The environmental atmosphere must be free of aggressive dust, corrosive vapours, gases and
liquids. The generator is to be protected against moisture according to IP 55.
Synchronous generators with integrated electronics may not be operated in areas classified as
dangerous, unless they are installed and certified in an approved housing.
The generators are designed for foot assembly
Make sure that the heat produced by the generator can be dissipated. The ventilator screen must always be kept
free, in order to ensure an adequate supply of fresh air. All heat sources must be considered when determining
the ambient temperature, so that the temperature does not rise above the permissible maximum value for the
generator.