4.5
Assembly Plan Power Generator
7
8
1
2
3
4a
5
6
7
8
9
Power generator CoolGen 4
MFD display
Operating pushbutton on the operating lever
Variant A switch line
Control line
Magnet line 230 volt
Plug-and-socket device
Magnet connection line
Lifting magnet
The essential components are:
3
2
1
4a
4b
5
6
7
9
4b
Variant B switch line
After the start/stop command has been given LEDs 3 & 4 flash
Anzeige:
- LED 3 (red, flashing), „Power off“
- LED 4 (red, flashing), „Line open“
Possible cause:
Due to speed fluctuations, the internal intermediate
circuit voltage rises above the allowable value.
Note :
The power generator is to be immediately shut down
until the fault has been corrected.
Contact the MOZELT Service Department
immediately. The fault indication can only be
cancelled by shutdown of the power generator.
1
2
3
4
5
Fig.: 30 |
MFD signals increased
intermediate circuit voltage
Fig.: 31 | General view arrangement power supply system CG 4