3.8
Terminal Block
Wiring of the hydraulic and temperature sensor terminals is always arranged in the same way. Due to the various
switch wirings there are the following possibilities:
3.8.1 Start command via switch line on the MFD display
During run-up of the power generator, the electronics detects a signal at terminal 7.
Thus, the display pushbutton on the MFD is activated and the pushbutton input at terminals 5 & 9 is deactivated.
3.8.2 Start Command via Terminal Block
During run-up of the power generator, the electronics detects the missing signal at terminal 7.
Thus, the display pushbutton is deactivated and the pushbutton input on terminals 5 & 9 activated.
1
2 3 4
5 6 7
8
9
10 11
Hydraulic control
HydraBrain
Pushbutton wiring
Temperature sensor
generator
Bridge
Internal
Temperature
sensor
MFD Display
Keying signal
Keying signal
on the display
deactivated
3.9
USB Connection
On the control card and MFD, there is an USB port. Both USB connections are identical and allow the following
functions via the DriveSoft service software (see Annex DriveSoft):
• Changing of the output voltage
• Changing of the ramps of the lifting and detachment behaviour of the magnet
• Adjustments for sorting operation
•
Fault analysis
• Operating states (speed, temperature, operating hours, output voltage, etc.)
• Oscilloscope function
•
Firmware updates
1
2 3 4
5 6 7
8
9
10 11
Hydraulic control
HydraBrain
Pushbutton wiring
Temperature sensor
generator
See Annex
„HydraBrain“ Unit
Bridge
Internal
Temperature
sensor
MFD Display
Switch line
Keying signal
Fig.: 10 | Terminal allocation on the terminal block (pushbutton on MFD activated)
Fig.: 11 | Terminal allocation on terminal block (pushbutton on terminal block activated)
Fig.: 12 | USB connection on
the control card
See Annex
„HydraBrain“ Unit