only LED 5 (red),
„R.P.M not o.k.“, possibly
also flashing.
Anzeige:
Possible cause:
Note:
1
The display „Ready“ flashes
Indication:
Possible cause:
Note:
4
The display „Line open“ flashes
The display „R.P.M not o.k.“ lights up
Indication:
Possible cause:
Only LED 5 (red), „R.P.M not o.k.“
If the power generator runs for several seconds at a
speed in the overspeed range, it is shut down.
Switching-off can only be cancelled by shutdown of
the power generator.
Shut down the motor immediately and have the
speed checked to avoid damage to the power
generator!
5
Fig.: 27 |
MFD signals shutdown due to
overspeed
WARNING
Fig.: 28 |
MFD signals overtemperature
Fig.: 29 | MFD signals insulation fault
LED 1 (yellow, flashing), „Ready“.
Power generator overheated and cannot be started.
The power generator operates at an unallowable
ambient temperature. The fresh air supply to the
power generator is not sufficient.
The power generator is again ready for operation
as soon as the normal temperate has been reached
again.
LED 4 (red, flashing), „Line open“.
- The magnet has an insulation fault.
The power generator is to be immediately shut
down until the insulation fault has been corrected.
The fault indication can only be cancelled by
shutdown of the power generator.