![MOZELT CoolGen 4 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/mozelt/coolgen-4/coolgen-4_technical-manual_1842904020.webp)
MOZELT GmbH & Co. KG
Load lifting magnet devices
Technical manual:
CoolGen 4
Copyright:
MOZELT GmbH & Co. KG, D-47269 Duisburg
Edition:
August 2014
Rev.:
00
Page 20
English
No LED indicator recognizable, possibly also
all LED lights up.
- Cable damage / power breakdown in the
control cable.
Generator runs within its working range, however, no function is
recognizable or all LED light up
Fig.: 24 | MFD has no function / all LED
light up
Indication:
Possible cause:
LED 1 (yellow),
„Ready“,
LED 5 (red, flashing), „R.P.M not o.k.“.
The display „R.P.M not o.k.“ flashes and the indication „Ready“ is on
5
Fig.: 25 | MFD signals „R.P.M not o.k.“
Indication:
Possible cause:
The power generator runs at overspeed.
Shut down motor immediately and have the
speed checked to prevent damage to the power
generator!
WARNING
The display „R.P.M not o.k.“ lights up
Fig.: 26 |
MFD signals underspeed
Indication:
Possible cause:
Note:
only LED 5 (red),
„R.P.M not o.k.“, possibly
also flashing.
The power generator runs at underspeed.
Have the speed checked!
LED 5 (steady light), speed of 1650 - 2000 rpm
LED 5 (flashing), speed of 2000 - 2350 rpm
5
1