PT-7828 User’s Manual
Featured Functions
3-64
Event Type
Event Types can be divided into two basic groups:
System Events
and
Port Events
. System
Events are related to the overall function of the switch, whereas Port Events are related to the
activity of a specific port.
System Events
Warning e-mail is sent when…
Switch Cold Start
Power is cut off and then reconnected.
Switch Warm Start
PT-7828 is rebooted, such as when network
parameters are changed (IP address, subnet mask,
etc.).
Power Transition (On
Æ
Off)
PT-7828 is powered down.
Power Transition (Off
Æ
On)
PT-7828 is powered up.
Configuration Change Activated Any configuration item has been changed.
Authentication Failure
An incorrect password is entered.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have changed
their position (applies only to the root of the tree).
If the Master of the Turbo Ring has changed or the
backup path is activated.
Port Events
Warning e-mail is sent when…
Link-ON
The port is connected to another device.
Link-OFF
The port is disconnected (e.g., the cable is pulled out,
or the opposing device shuts down).
Traffic-Overload
The port’s traffic surpasses the Traffic-Threshold for
that port (provided this item is Enabled).
Traffic-Threshold (%)
Enter a nonzero number if the port’s Traffic-Overload
item is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration
seconds if the average
Traffic-Threshold is surpassed during that time
period.