length between 1 and 1024 bytes is specified, data in the buffer will be sent as soon it reaches the specified 
length. 

Delimiter 1 and Delimiter 2 (default=None): When Delimiter 1 is enabled, the serial port will clear the 
buffer and send the data to the Ethernet port when a specific character, entered in hex format, is received. A 
second delimiter character may be enabled and specified in the Delimiter 2 field, so that both characters act as 
the delimiter to indicate when data should be sent. 

 

ATTENTION 

In order to enable a delimiter, packet length must be set to 0. Delimiter 2 should only be enabled in 
conjunction with Delimiter 1 and never on its own; otherwise there may be data errors. Even when a delimiter 
is enabled, the NPort 6000 will still pack and send the data when the amount of data exceeds 1 KB

 

Delimiter process (default=Do Nothing): The Delimiter process field determines how the data is handled 
when a delimiter is received. Delimiter 1 must be enabled for this field to have effect. If Delimiters 1 and 2 are 
both enabled, both characters must be received for the delimiter process to take place. 

 

Do Nothing: Data in the buffer will be transmitted when the delimiter is received. 

 

Del 1: Data in the buffer will be transmitted after 1 additional byte is received following the 
delimiter. 

 

Del 2: Data in the buffer will be transmitted after 2 additional bytes are received following the 
delimiter. 

 

Strip Delimiter: Data in the buffer is first stripped of the delimiter before being transmitted. 

Force transmit (default=0 ms): This parameter defines how large a gap in serial communication the NPort 
6000 will allow before packing the serial data in its internal buffer for network transmission. 

UDP Mode 

 

Destination address 1 through 4 (default=None): In UDP mode, you may specify up to 4 ranges of IP 
addresses for the serial port to connect to. At least one destination range must be provided. 

Содержание NPort 6000 Series

Страница 1: ...NPort 6000 Series User s Manual Sixth Edition March 2011 www moxa com product 2011 Moxa Inc All rights reserved...

Страница 2: ...provements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However...

Страница 3: ...nfiguration Options 3 2 NPort Search Utility 3 2 Web Console 3 2 LCM Console Front Panel NPort 6610 6650 and 6450 only 3 2 ARP 3 3 Telnet Console 3 4 Serial Console 3 6 4 Introducing Serial Port Opera...

Страница 4: ...ction Master Mode 7 14 Pair Connection Slave Mode 7 15 Ethernet Modem Mode 7 16 Terminal Applications 7 19 Terminal ASCII TERM_ASC 7 19 Terminal BIN TERM_BIN 7 20 SSH 7 22 Reverse Terminal Application...

Страница 5: ...nstalling NPort Search Utility 10 12 Configuring NPort Search Utility 10 14 Linux Real TTY Drivers 10 15 Basic Procedures 10 15 Hardware Setup 10 15 Installing Linux Real TTY Driver Files 10 15 Mappin...

Страница 6: ...ent Server Architecture F 2 Setting up the NPort 6000 F 2 Setting up the RADIUS Server IP Address F 2 Serial Port Configuration F 3 Setting up UNIX Hosts F 3 Setting up Windows NT Hosts F 3 Setting up...

Страница 7: ...ons and information presented for the NPort 6000 apply to all models in the series Any differences between models will be specified Please refer to the Product Selection Chart section in this chapter...

Страница 8: ...resumption of communication the buffered data will be sent to the destination The default size of the port buffer is 64 KB for each port For the NPort 6610 NPort 6250 NPort 6450 and NPort 6650 users...

Страница 9: ...two 100BaseFX multi mode fiber ports SC connectors supports cascade redundancy NM GPRS GSM GPRS GSM modem module NM Modem NM Modem T 56K V 92 modem module NPort 6150 NPort 6250 and NPort 6450 One mod...

Страница 10: ...SECC sheet metal 1 mm Ethernet yes yes yes 6610 16 16 RS 232 100 240 VAC SECC sheet metal 1 mm Ethernet yes yes yes 6610 32 32 RS 232 100 240 VAC SECC sheet metal 1 mm Ethernet yes yes yes 6610 8 48V...

Страница 11: ...T 2000 Windows XP 2003 Vista 2008 7 x86 x64 Embedded CE 5 0 6 0 XP Embedded Fixed TTY Drivers SCO Unix SCO OpenServer UnixWare 7 UnixWare 2 1 SVR 4 2 QNX 4 25 QNX 6 Solaris 10 FreeBSD AIX 5 x Linux Re...

Страница 12: ...ears Details See www moxa com warranty NPort 6250 6250 S SC 6250 M SC Ethernet Interface Number of Ports 1 Speed 10 100 Mbps auto MDI MDIX Connector 8 pin RJ45 Magnetic Isolation 1 5 KV built in Optic...

Страница 13: ...2 QNX 4 25 QNX 6 Solaris 10 FreeBSD AIX 5 x Linux Real TTY Drivers Linux kernel 2 4 x 2 6 x Management SNMP MIB II IP Routing Static RIP I RIP II Operation Modes Standard Real COM TCP Server TCP Clie...

Страница 14: ...tic Reboot Trigger Built in WDT watchdog timer MTBF meantime between failures NPort 6250 226128 hrs NPort 6250 M SC 225762 hrs NPort 6250 S SC 225762 hrs Warranty Warranty Period 5 years Details See w...

Страница 15: ...AES SSH SSL Configuration Options Web Console Serial Console Telnet Console Windows Search Utility Windows Real COM Drivers Windows 95 98 ME NT 2000 Windows XP 2003 Vista 2008 7 x86 x64 Embedded CE 5...

Страница 16: ...34 IEC 68 2 32 Vibration IEC 68 2 6 IEC 68 2 34 Green Product RoHS CRoHS WEEE Reliability Alert Tools Built in buzzer and RTC real time clock Automatic Reboot Trigger Built in WDT watchdog timer MTBF...

Страница 17: ...UDP DHCP BOOTP Telnet DNS SNMP V1 V2c V3 HTTP SMTP ARP PPPoE Security Protocols DES 3DES AES SSH SSL Configuration Options Web Console Serial Console Telnet Console Windows Search Utility Windows Real...

Страница 18: ...1000 4 5 Standards and Certifications Safety UL 60950 1 EN 60950 1 EMC CE FCC EMI EN 55022 Class A FCC Part 15 Subpart B Class A EMS EN 55024 EN 61000 4 2 ESD Level 2 3 EN 61000 4 3 RS Level 2 EN 6100...

Страница 19: ...vered in this chapter Panel Layout NPort 6150 6250 NPort 6450 NPort 6610 6650 Panel DIN Rail and Rack Mounting Connecting the Hardware Wiring Requirements Connecting the NPort 6600 32 16 8 48V s Power...

Страница 20: ...NPort 6000 Series Getting Started 2 2 Panel Layout NPort 6150 6250 NPort 6150 NPort 6250 NPort 6450...

Страница 21: ...NPort 6000 Series Getting Started 2 3 NPort 6610 6650...

Страница 22: ...heads of the screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NPort 6150 NPort 6250 NPort 6450 DIN Rail Mounting...

Страница 23: ...parately The type of signal transmitted through a wire should determine which wires should be kept separate The rule of thumb is that wires sharing similar electrical characteristics may be bundled to...

Страница 24: ...cessories LED Indicators The LED indicators on the front panel of the NPort 6000 are described in the following table LED Name LED Color LED Function PWR Red Power is being supplied to the power input...

Страница 25: ...t is receiving data Off No data is being received through the modem port Adjustable Pull High Low Resistors for the RS 485 Port In some critical environments you may need to add termination resistors...

Страница 26: ...NPort 6000 Series Getting Started 2 8 NPort 6150 6250 6450 Jumpers NPort 6150 NPort 6250 NPort 6450...

Страница 27: ...NPort 6000 Series Getting Started 2 9 NPort 6650 DIP Switches SW 1 2 3 Pull High Pull Low Terminator ON 1 K 1 K 120 K OFF 150 K 150 K...

Страница 28: ...different methods that can be used Refer to Chapter 9 System Management Settings for more details about network settings The following topics are covered in this chapter Static and Dynamic IP Address...

Страница 29: ...address are not directly accessible from a public network For example you would not be able to ping a device with a private IP address from an outside Internet connection If your application requires...

Страница 30: ...etwork setting menu select IP address 6 Use the UP and DOWN buttons to modify the digit currently selected by the blinking cursor Press SEL to move to the next digit Continue modifying the IP address...

Страница 31: ...essful Telnet Console Depending on how your computer and network are configured you may find it convenient to use network access to set up your NPort 6000 s IP address This can be done using Telnet AT...

Страница 32: ...en type in the new IP address and press ENTER Note that if you are using a dynamic IP configuration BOOTP SHCP etc you will need to go to the IP configuration field and press ENTER to select the appro...

Страница 33: ...nal emulator utility although your actual screens and procedures may vary slightly from the following instructions 1 Turn off the power to the NPort 6000 Use a serial cable to connect the NPort 6000 s...

Страница 34: ...ey usually found next to the number 1 key The NPort 6000 will then automatically switch from data mode to console mode 7 If the NPort 6000 has been set up for password protection you will be prompted...

Страница 35: ...hapter 5 Configuration with the Web Console for detailed information on configuration parameters The following topics are covered in this chapter Overview Guide to NPort 6000 Modes Device Control Appl...

Страница 36: ...preserve your existing COM TTY based software without needing to invest in additional software Three different socket modes are available TCP Server TCP Client and UDP Server Client The main differen...

Страница 37: ...ns The Real COM driver intercepts data sent to the host s COM port packs it into a TCP IP packet then redirects it through the host s Ethernet card At the other end of the connection the NPort 6000 ac...

Страница 38: ...elnet protocol Third party drivers supporting RFC 2217 are widely available on the Internet and can be used to implement Virtual COM mapping to your NPort 6000 serial port s Socket Applications For so...

Страница 39: ...sion proceeds as follows 1 The NPort 6000 configured for TCP Client mode requests a connection from the host 2 Once the connection is established data can be transmitted in both directions between the...

Страница 40: ...port to the COM port of a PC or another type of computer such as a hand held PDA that has a serial port the other server is connected to the serial device through its RS 232 port The two servers are t...

Страница 41: ...minal modes support fast keys as used in many terminal applications Please refer to Chapter 4 Introducing Serial Port Operation Modes for detailed information and configuration instructions Terminal A...

Страница 42: ...dministrator to telnet to the device remotely through the network Although modern network equipment generally allows other options for remote configuration through the network there are situations in...

Страница 43: ...g demands Printer modes involve a network printer that is connected to a serial port on the NPort 6000 with a port number assigned to specify the printer s location Windows or UNIX hosts can access th...

Страница 44: ...n Chapter 9 System Management Settings for instructions on setting up the NPort 6000 User Table The NPort 6000 supports PPP SLIP and Terminal modes for dial in dial out access Regardless of which oper...

Страница 45: ...web console and go through the basic configuration options The same configuration options are also available through the Telnet and serial console The following topics are covered in this chapter Usin...

Страница 46: ...lorer enable cookies by selecting Internet Options from the Tools menu 2 Select the Privacy tab There are six levels of privacy setting Block All Cookies High Medium High Medium Low and Accept All Coo...

Страница 47: ...trusted sites through Internet Options in the Tools menu of Internet Explorer Select the Security tab then click on the Trusted Sites icon and on the Sites button 2 In either case the window below sh...

Страница 48: ...iguration for details on how to configure the IP address The default login username is admin with no password Note that only the user admin can upgrade the firmware ATTENTION If you forget your passwo...

Страница 49: ...t restarting by selecting Save Configuration in the navigation panel If you restart the NPort 6000 without saving your configuration the NPort 6000 will discard all submitted changes Basic Settings Yo...

Страница 50: ...Greenwich Mean Time This field shows the currently selected time zone and allows you to select a different time zone Local time This field shows the time that you last opened or refreshed the browser...

Страница 51: ...t If the address is on the same network segment as the NPort 6000 a connection is established directly from the NPort 6000 Otherwise the connection is established through the given default gateway Gat...

Страница 52: ...he Internet IPv6 Configuration default Static You can choose from three possible IP configuration modes Option Description Auto IPv6 router assigned prefix Step 1 NPort generates the Link local addres...

Страница 53: ...negotiation of transfer speed However some switches hubs require that the communication speed be fixed at 100 Mbps or 10 Mbps Note that there is no option for configuring the network speed for the op...

Страница 54: ...hen Misc Network Settings in the navigation panel The route table is where you configure how the NPort 6000 will connect to an outside network You are allowed up to 32 entries in the route table For e...

Страница 55: ...ich is not on the local network 203 67 6 xxx This causes the NPort 6000 to act as a router and send the datagram to the default next hop router 203 67 6 254 In this case we should add the gateway IP a...

Страница 56: ...al in users can make requests to Intranet hosts 202 65 66 4 or 202 65 66 5 which are on network 202 65 66 xxx located outside network 203 67 6 xxx You will need to add a route entry for the next hop r...

Страница 57: ...responding NPort 6000 delivers the request to the another NPort 6000 on the remote end 202 6 6 254 or 201 2 2 254 as the next hop router For this example assume that Modem 1 is connected to serial por...

Страница 58: ...available from the Telnet and serial consoles The following topics are covered in this chapter NM TX01 NM TX02 NM FX01 M SC NM FX01 S SC NM FX02 M SC NM FX02 S SC Using Ethernet Redundancy The STP RS...

Страница 59: ...les listed below NM TX01 NM TX01 T Ethernet module with 1 RJ45 port NM TX02 NM TX02 T Ethernet module with2 RJ45 ports NM FX01 S SC NM FX01 S SC T Ethernet module with a single mode fiber port and SC...

Страница 60: ...g it relatively easy to deploy For example Defaults to sending 802 1D style BPDUs if packets with this format are received STP 802 1D and RSTP 802 1w can operate on different ports of the same NPort 6...

Страница 61: ...the path through Bridge B After the failure of Bridge C STP re evaluated the situation and opened the path through Bridge B How STP Works When enabled STP determines the most appropriate path for traf...

Страница 62: ...guration After all the bridges on the network agree on the identity of the Root Bridge and all other relevant parameters have been established each bridge is configured to forward traffic only between...

Страница 63: ...Port for LAN Segment 1 Ports 1 of Bridges B C X and Y are all Root Ports since they are nearest to the Root Bridge and therefore have the most efficient path Bridges B and X offer the same Root Path C...

Страница 64: ...amount of time the root waits between sending hello messages 2 Forward Delay Setting Description Factory Default Numerical value input by user The amount of time this device waits before checking to s...

Страница 65: ...p 1 Assign a value to Hello Time and then calculate the left most part of Eq 4 to get the lower limit of Max Age Step 2 Assign a value to Forwarding Delay and then calculate the right most part of Eq...

Страница 66: ...e the segment that will be blocked during normal operation is determined by the number of EDS units that make up the ring and where the ring master is located When the number of NPort 6000 units in t...

Страница 67: ...t 6000 to be one of the redundant ports Port 2 NM GPRS GSM This section applies to NPort 6000 server s that have the NM GPRS GSM module installed From the left navigation panel click Network Settings...

Страница 68: ...setting of 0 ms will cause the port to remain connected even if idle Link quality report default Disable Setting this field to Enable allows the NPort 6000 to disconnect a connection if the link noise...

Страница 69: ...Ethernet host returns to normal data will revert to being sent over Ethernet after 5 continuous successful pings Backup Connection interval default 5 min The time interval of Periodically connect func...

Страница 70: ...ssage Service SMS is a telecommunications protocol that allows the sending of short 160 characters or less text messages It is available on most digital mobile phones and some personal digital assista...

Страница 71: ...vent These settings are only available on the NPort 6610 6450 and 6650 Ethernet1 refers to the built in Ethernet port These settings configure the NPort to change the status of the relay output and al...

Страница 72: ...rmation DSR changed A change in the DSR Data Set Ready signal indicates that the data communication equipment is powered off For example if the DSR signal changes to low it indicates that the data com...

Страница 73: ...certain threshold Username This is the dial out user ID account Password This is the dial out user password Authentication type default None This field allows you to configure the method used if any t...

Страница 74: ...nnection interval setting to Modem after power on Inactivity time is up Trunk Remote host fail remote host recovered Remote Ethernet host has failed The NPort 6000 will check the remote host connectio...

Страница 75: ...de RFC2217 Mode Socket Applications TCP Server Mode TCP Client Mode UDP Mode Pair Connection Mode Pair Connection Master Mode Pair Connection Slave Mode Ethernet Modem Mode Terminal Applications Termi...

Страница 76: ...d configure the mode for each serial port For NPort 6000 models with 2 or more serial ports you may use the checkboxes at the bottom of the window to apply the settings to one or more ports Applicatio...

Страница 77: ...ined here in the web console and all hosts connected to the port must use identical serial settings If one of the hosts opens the COM port with different serial settings data will not be transmitted p...

Страница 78: ...ard to last requester Forward non requested serial data to last requester connection Forward to all open connections Forward non requested serial data to all open connections Packet length default 0 T...

Страница 79: ...tion to close For socket and device control modes the NPort 6000 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP conne...

Страница 80: ...tate to low when the Ethernet connection goes down Use always high if you do not want the Ethernet connection status to affect the RTS or DTR signals Packet length default 0 The Packet length setting...

Страница 81: ...and no parity In this case the total number of bits needed to send a character is 10 bits and the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should...

Страница 82: ...t both characters act as the delimiter to indicate when data should be sent ATTENTION In order to enable a delimiter packet length must be set to 0 Delimiter 2 should only be enabled in conjunction wi...

Страница 83: ...data is sent on a first in first out basis to the serial port when data comes into the NPort 6000 from the Ethernet interface Ignore jammed IP default Disable This option determines how the port will...

Страница 84: ...ted serial data to last requester connection Forward to all open connections Forward non requested serial data to all open connections Packet length default 0 The Packet length setting refers to the m...

Страница 85: ...ond to the packet within the time specified in this field the NPort 6000 will force the existing TCP connection to close For socket and device control modes the NPort 6000 will listen for another TCP...

Страница 86: ...e applications the user may need to send the data actively to the remote destination domain name Designated local port 1 through 4 default 5010 through 5013 Use these fields to specify the designated...

Страница 87: ...ocess default Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are...

Страница 88: ...ault Do Nothing The Delimiter process field determines how the data is handled when a delimiter is received Delimiter 1 must be enabled for this field to have effect If Delimiters 1 and 2 are both ena...

Страница 89: ...ain open even if there is no response to the keep alive packets Secure default Disable If you select Enable data sent through the Ethernet will be encrypted with SSL ATTENTION When establishing a Pair...

Страница 90: ...enter data mode TCP alive check time default 7 min This field specifies how long the NPort 6000 will wait for a response to keep alive packets before closing the TCP connection The NPort 6000 checks c...

Страница 91: ...ort 6000 will enter command mode and after 1 second you can then enter ATH to shut down the TCP connection The NPort 600 0 will return a NO CARRIER via the serial port NOTE The command cannot be divid...

Страница 92: ...xt boot up S Registers No S Register Description default value Remarks 1 S0 Ring to auto answer default 0 2 S1 Ring counter always 0 no action applied 3 S2 Escape code character default 43 ASCII 4 S3...

Страница 93: ...periodic keep alive packets If the remote host does not respond to the packet within the time specified in this field the NPort 6000 will force the existing TCP connection to close For socket and dev...

Страница 94: ...eld defines the quick key to send a break signal Interrupt This field defines the quick key for program termination Auto login prompt default ogin Password prompt default password Login user name Ente...

Страница 95: ...applications may require that the terminal type be transmitted before the connection can be established You may need to refer to the server s documentation to determine the appropriate terminal type...

Страница 96: ...a transfer is completed Primary and Secondary host address If specified the fields designate permanent hosts to which the terminal will always be connected SSH TCP port default 22 By default the SSH T...

Страница 97: ...o the keep alive packets Inactivity time default 0 min This field specifies the idle time setting for auto disconnection A setting of 0 min will cause the port to remain connected even if idle TCP por...

Страница 98: ...force the existing TCP connection to close For socket and device control modes the NPort 6000 will listen for another TCP connection from another host after closing the connection If TCP alive check...

Страница 99: ...ns RAW PRN Mode TCP alive check time default 7 min This field specifies how long the NPort 6000 will wait for a response to keep alive packets before closing the TCP connection The NPort 6000 checks c...

Страница 100: ...For socket and device control modes the NPort 6000 will listen for another TCP connection from another host after closing the connection If TCP alive check time is set to 0 the TCP connection will rem...

Страница 101: ...is is the dial out user password Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Option Description Local Verify the...

Страница 102: ...out user ID account Password This is the dial out user password Authentication type default None This field allows you to configure the method used if any to verify a user s ID and authorization Optio...

Страница 103: ...If this field is set as DSR off the connection will be disconnected when the DSR signal is off SLIPD Mode SLIPD SLIP on demand is used for dial in services since it provides SLIP services only when re...

Страница 104: ...al Verify the ID against the NPort 6000 User Table RADIUS Verify the ID against the external RADIUS server RADIUS Local Radius authentication is tried first switching to Local if unsuccessful Local RA...

Страница 105: ...tings on the NPort 6000 The same configuration options are also available through the telnet and serial console The following topics are covered in this chapter Port Communication Parameters Serial Pa...

Страница 106: ...losest supported baudrate The margin for error will be less than 1 7 for all baudrates under 921600 bps Data bits default 8 This field configures the data bits parameter Note If data bits is set to 5...

Страница 107: ...buffering SD file size default 1 Megabyte Use this field to configure the size of the port buffer if you have configured it to reside on an SD card Note that optional SD cards are not supported on th...

Страница 108: ...SSL and SSH to build secure connections The Secure Mode SSL Ciphers are for when Secure mode is be selected The SSH Reverse SSH Ciphers are only for SSH terminals and Reverse SSH terminals Welcome Mes...

Страница 109: ...og Server Auto Warning Settings Event Settings Serial Event Settings E mail Alert SNMP Trap Maintenance Console Setting Ping Firmware Upgrade Configuration Import Export Load Factory Defaults Change P...

Страница 110: ...ow access to a specific IP address Enter the IP address in the corresponding field enter 255 255 255 255 for the netmask To allow access to hosts on a specific subnet For both the IP address and netma...

Страница 111: ...Read write access control The following fields allow you to define user names passwords and authentication parameters for two levels of access read only and read write The name of the field will indi...

Страница 112: ...rt 6000 Host Table The Host Table may be used to simplify IP address entry on the NPort 6000 console by assigning a Host Name to a Host IP Address When you assign a Host Name to a Host IP Address you...

Страница 113: ...r for user authentication enter its IP address or domain name here TACACS secret If you are using a TACACS server for user authentication enter its password here TACACS accounting Use this field to en...

Страница 114: ...d The NPort 6000 s configuration was changed Firmware Upgrade Firmware was upgraded SSL Certificate Import SSL Certificate was impoted Config Import Config was impoted Config Export Config was expoted...

Страница 115: ...re only available on the NPort 6450 and 6650 Ethernet1 refers to the built in Ethernet port and Ethernet2 and Ethernet3 refers to Ethernet ports that are added through optional network modules These s...

Страница 116: ...ors may reset its status by selecting Acknowledge Event from the NPort 6000 console or by correcting the DCD signal Please refer to the section on System Monitoring later in this chapter for more info...

Страница 117: ...ay not work properly if it is not configured correctly The NPort 6000 s SMTP AUTH supports LOGIN PLAIN and CRAM MD5 RFC 2554 Mail server This field is for your mail server s domain name or IP address...

Страница 118: ...PS Telnet SSH can be enabled or disabled The NPort 6000 front panel known as the LCM Liquid Crystal Module may be configured for read only or writeable access In other words you can use the front pane...

Страница 119: ...arch Utility If you have made any changes to your configuration remember to save the configuration first before upgrading the firmware Please refer to Save Configuration later in this chapter for more...

Страница 120: ...configuration file If you also wish to import the IP configuration i e the NPort 6000 s IP address netmask gateway etc make sure that Import all configurations including IP configurations is checked o...

Страница 121: ...he existing password enter your desired password under both New password and Confirm password To remove password protection leave the New password and Confirm password boxes blank ATTENTION If you for...

Страница 122: ...e Key Delete System Monitoring Serial to Network Connections Go to Serial to Network Connections under Serial Status to view the operation mode and status of each connection for each serial port All m...

Страница 123: ...port Frame Framing error indicates that the received character did not have a valid stop bit Parity Parity error indicates that the received data character does not match the parity selected Overrun T...

Страница 124: ...ttings Go to Serial Port Settings under Serial Status to view a summary of the settings for each serial port Serial Cipher Usage Status Serial Status Cipher Usage Status Monitor cipher usage and conne...

Страница 125: ...n information Network Statistics Go to Network Statistics under System Status to view network statistics Ethernet statistics Sent Total number of output datagram packets delivered to the Ethernet Rece...

Страница 126: ...ics Received Received packets of ICMP messages Sent Sent packets of ICMP messages REchoReq Received packets from remote Ping request REchoRply Responding packets to remote Ping request SEchoReq Receiv...

Страница 127: ...ot need to set the master to use Turbo Ring If no master is set the Turbo Ring protocol will assign master status to one of the EDS units in the ring The master is only used to determine which segment...

Страница 128: ...gs 9 20 System Log This option displays the system log You may click Select all to select the entire log if you wish to copy and paste the contents into a text file Routing Go to Routing under System...

Страница 129: ...er System Status to display the PPP Trace information PPP states for the selected ports are shown LCP Link Control Protocol which is an essential part of the PPP link is used for establishing configur...

Страница 130: ...h memory The configuration changes will then be effective when the NPort 6000 is restarted If you do not save your changes before restarting they will be discarded Restart Restart System Go to Restart...

Страница 131: ...eries System Management Settings 9 23 Restart Ports Go to Restart Ports under Restart and then select the ports to be restarted Click Select All to select all the ports Click Submit to restart the sel...

Страница 132: ...Using NPort Windows Driver Manager NPort Search Utility Installing NPort Search Utility Configuring NPort Search Utility Linux Real TTY Drivers Basic Procedures Hardware Setup Installing Linux Real T...

Страница 133: ...ial ports that are set to Real COM mode The software manages the installation of drivers that allow you to map unused COM ports on your PC to serial ports on the NPort 6000 These drivers are designed...

Страница 134: ...splays a summary of the installation options 5 Click Install to begin the installation The setup window will report the progress of the installation To change the installation settings click Back and...

Страница 135: ...ost Make sure that the serial port s on your NPort 6000 are set to Real COM mode when mapping COM ports with the NPort Windows Driver Manager 1 Go to Start NPort Windows Driver Manager NPort Windows D...

Страница 136: ...page supports FQDN Fully Qualified Domain Name in which case the IP address will be filled in automatically 5 COM ports and their mappings will appear in blue until they are activated Activating the...

Страница 137: ...figuration 10 6 6 In Windows XP a message is displayed during activation of each port indicating that the software has not passed Windows Logo certification Click Continue Anyway to proceed 7 Ports th...

Страница 138: ...he NPort Windows Driver Manager 1 Go to Start NPort Windows Driver Manager NPort Windows Driver Manager to start the COM mapping utility 2 Click the Add icon 3 Select Input Manually and click Reverse...

Страница 139: ...of NPort The MAC address of NPort A for identification 00 90 18 18 f1 36 1st Mapping Port Index Index the port 3 3 Total Number of Ports From port 3 to port 15 will be mapped and the total number of p...

Страница 140: ...ponding to the desired port and then click the Setting icon 1 On the Basic Setting window use the COM Number drop down list to select a COM number to be assigned to the NPort 6000 s serial port that i...

Страница 141: ...ABLE when a connection cannot be established to the NPort 6000 This usually means that your host s network connection is down perhaps due to a cable being disconnected However if you can reach other n...

Страница 142: ...immediately without restarting the COM ports If your application will open close COM ports frequently and the NPort 6000 is only for one host you can enable this option to speed up the opening closin...

Страница 143: ...nfiguration file to another host and use the same COM Mapping settings in the other host NPort Search Utility Installing NPort Search Utility 1 Click the INSTALL UTILITY button in the NPort Installati...

Страница 144: ...program files to the default directory or click Browse to select an alternate location 4 Click Next to install the program s shortcuts in the appropriate Start Menu folder 5 Click Next to proceed with...

Страница 145: ...rch Utility The Broadcast Search function is used to locate all NPort 6000 servers that are connected to the same LAN as your computer After locating an NPort 6000 you will be able to change its IP ad...

Страница 146: ...the NPort serial port to the host s tty port Hardware Setup Before proceeding with the software installation make sure you have completed the hardware installation Note that the default IP address for...

Страница 147: ...tarts the driver Mapping tty ports automatically To map tty ports automatically you may execute mxaddsvr with just the IP address and number of ports as in the following example cd usr lib npreal2 dri...

Страница 148: ...er Installing the UNIX Driver 1 Log in to UNIX and create a directory for the Moxa TTY To create a directory named usr etc execute the command mkdir p usr etc 2 Copy moxattyd tar to the directory you...

Страница 149: ...vice naming rule For UnixWare 7 UnixWare 2 1 x and SVR4 2 use pts n For all other UNIX operating systems use ttyp n Starting moxattyd Execute the command init q or reboot your UNIX operating system Ad...

Страница 150: ...endix Port Pinout Diagrams NPort 6150 6250 6450 RS 232 422 485 male DB9 NPort 6600 RS 232 422 485 male RJ45 Cable Wiring Diagrams Ethernet Cables Serial Cables RS 232 Serial Cables RS 422 4 Wire RS 48...

Страница 151: ...e DB9 PIN RS 232 RS 422 RS 485 4W RS 485 2W 1 DCD TxD A 2 RXD TxD B 3 TXD RxD B Data B 4 DTR RxD A Data A 5 GND GND GND 6 DSR 7 RTS 8 CTS 9 NPort 6600 RS 232 422 485 male RJ45 PIN RS 232 RS 422 RS 485...

Страница 152: ...NPort 6000 Series Pinouts and Cable Wiring A 3 Cable Wiring Diagrams Ethernet Cables Serial Cables RS 232 RJ45 8 pin to Female DB9...

Страница 153: ...NPort 6000 Series Pinouts and Cable Wiring A 4 RJ45 8 pin to Male DB9 RJ45 8 pin to Female DB25 RJ45 8 pin to Male DB25...

Страница 154: ...NPort 6000 Series Pinouts and Cable Wiring A 5 Serial Cables RS 422 4 Wire RS 485 RJ45 8 pin to Female DB9 RJ45 8 pin to Male DB9 RJ45 8 pin to Female DB25...

Страница 155: ...NPort 6000 Series Pinouts and Cable Wiring A 6 RJ45 8 pin to Male DB25 Serial Cables 2 wire RS 485 RJ45 8 pin to Female DB9 RJ45 8 pin to Male DB9 RJ45 8 pin to Female DB25...

Страница 156: ...5 8 pin to Male DB25 Pin Assignments for DB9 and DB25 Connectors Pin Assignments for DB9 Male and Female Connectors DB9 Male Connector DB9 Female Connector Pin Assignments for DB25 Male and Female Con...

Страница 157: ...mode as RFC2217 mode By default the first serial port on the NPort 6000 is assigned TCP port 4001 the second serial port is assigned TCP port 4002 and so on 2 Download and install a third party drive...

Страница 158: ...the Internet from home or the office enter the IP address of the NAS in a web browser provided a fixed public IP is assigned to the server However most users have installed their NAS servers behind a...

Страница 159: ...yndns com Configuration DDNS default Disable Use this field to enable or disable DDNS Server address default DynDns org Currently DynDns org is the only option available for Server address Host name I...

Страница 160: ...most systems can only be used by system processes or by programs executed by privileged users The following table shows famous port numbers among the listed well known port numbers For more details p...

Страница 161: ...42 Host name server names server 43 Whois nickname 49 Login Host Protocol login 53 Domain Name Server domain 69 Trivial Transfer Protocol TETP 70 Gopher Protocol 79 Finger Protocol 80 World Wide Web H...

Страница 162: ...tware that supports SNMP Trap RFC1317 and RS 232 like groups and RFC 1213 MIB II The following table lists the standard MIB II groups as well as the variable implementation for the NPort 6000 The foll...

Страница 163: ...Pkts ipOutNoRoutes icmpInAddrMasks ifInNUcastPkts ipReasmTimeout icmpInAddrMaskReps ifInDiscards ipReasmReqds icmpOutMsgs ifInErrors ipReasmOKs icmpOutErrors ifInUnknownProtos ipReasmFails icmpOutDest...

Страница 164: ...nnState snmpInTotalSetVars tcpConnLocalAddress snmpInGetRequests tcpConnLocalPort snmpInGetNexts tcpConnRemAddress snmpInSetRequests tcpConnRemPort snmpInGetResponses tcpInErrs snmpInTraps tcpOutRsts...

Страница 165: ...cketAllowDriverControl deviceControlLocalTcpPort socketSecure deviceControlConnectionDownRTS socketLocalTcpPort deviceControlConnectionDownDTR socketCmdPort socketTcpServerConnectionDownRTS socketTcpS...

Страница 166: ...ion terminalQuit terminalBreak terminalInterrupt terminalAuthenticationType terminalAutoLoginPrompt terminalPasswordPrompt terminalLoginUserName terminalLoginPassword printer Mode dial Mode dataPackin...

Страница 167: ...stName hostIpAddress routeTableIndex gatewayRouteTable destinationRouteTable netmaskRouteTable metricRouteTable interfaceRouteTable userTableIndex userNameUserTable passwordUserTable phoneNumberUserTa...

Страница 168: ...oadFactoryDefaultSetting sysStatus saveConfiguration restart remoteIpIndex saveConfig restartPorts monitorRemoteIp restartSystem monitorTxCount monitorRxCount monitorTxTotalCount monitorRxTotalCount m...

Страница 169: ...NPort 6000 Series SNMP Agents with MIB II RS 232 Like Groups E 8 portDCDChangedAcknowledge portDSRChangedStatus portDSRChangedAcknowledge...

Страница 170: ...ng user names and passwords as well as configuration of information that details the type of service to deliver to the user e g SLIP PPP Telnet and rlogin The NPort 6000 supports the RADIUS protocol w...

Страница 171: ...e place This greatly eases the management burden associated with administering a large number of dial in users Client Server Architecture RADIUS is a type of client server software Communication serve...

Страница 172: ...ing up UNIX Hosts Moxa recommends the FreeRADIUS server for UNIX users FreeRADIUS is the premiere open source RADIUS server and is one of the top five RADIUS servers in use world wide It is effective...

Страница 173: ...ick on it after which you will see RADIUS in the right information window 5 Right click RADIUS in the left information window and then select Properties 6 Select Service Verify that the RADIUS ports a...

Страница 174: ...you set in the NPort 6000 console 8 Click Apply 9 Right click RADIUS in the left information window and select Start You will now see that RADIUS is running Setting up Windows 2000 Hosts 1 Open Start...

Страница 175: ...NPort 6000 Series RADIUS Server F 6 4 Select Set up an advanced remote access server and click Next to continue 5 Select TCP IP protocol then click Next to continue...

Страница 176: ...NPort 6000 Series RADIUS Server F 7 6 Specify your IP address as shown on the following screens...

Страница 177: ...indows 2003 uses the IAS service instead of the RADIUS service For this reason you need to install the IAS service to use RADIUS with Windows 2003 The IAS service will not be installed by default 1 Cl...

Страница 178: ...ntinue clicking OK until the installation is complete 4 After the installation is complete click Administrative Tools and run the Internet Authentication Service This will open the following window 5...

Отзывы: