NPort 6000 Series
System Management Settings
9-8
Serial Event Settings
On the Serial Event Settings page, you may configure how administrators are notified of each serial port’s DCD
and DSR changes. Mail refers to sending an e-mail to a specified address. Trap refers to sending an SNMP Trap.
Dout is only available on the NPort 6450 and 6650, and refers to changing the status of the relay output (the
DOUT socket at the back of the NPort 6000) and of the alarm LED.
DCD changed
A change in the DCD (Data Carrier Detect) signal indicates that the modem connection status has changed. For
example, if the DCD signal changes to low, it indicates that the connection line is down. When the DCD signal
changes to low, the NPort 6000 will automatically send a warning to the administrator as configured on the
Serial Event Settings page.
For the NPort 6450 and 6650, after the relay output status has been changed, administrators may reset its
status by selecting Acknowledge Event from the NPort 6000 console, or by correcting the DCD signal. Please
refer to the section on System Monitoring later in this chapter for more information.
DSR changed
A change in the DSR (Data Set Ready) signal indicates that the data communication equipment is powered off.
For example, if the DSR signal changes to low, it indicates that the data communication equipment is powered
down. When the DSR signal changes to low, the NPort 6000 will automatically send a warning to the
administrator as configured on the Serial Event Settings page.
For the NPort 6450 and 6650, after the relay output status has been changed, administrators may reset its
status by selecting Acknowledge Event from the NPort 6000 console, or by correcting the DSR signal. Please
refer to the section on System Monitoring later in this chapter for more information.
ATTENTION
SNMP indicates a change in DCD or DSR signals but does not differentiate between the two. A change in either
signal from “–” to “+” is indicated by “link up” and a change in either signal from “+” to “–” is indicated by “link
down.”
Содержание NPort 6000 Series
Страница 20: ...NPort 6000 Series Getting Started 2 2 Panel Layout NPort 6150 6250 NPort 6150 NPort 6250 NPort 6450...
Страница 21: ...NPort 6000 Series Getting Started 2 3 NPort 6610 6650...
Страница 26: ...NPort 6000 Series Getting Started 2 8 NPort 6150 6250 6450 Jumpers NPort 6150 NPort 6250 NPort 6450...
Страница 153: ...NPort 6000 Series Pinouts and Cable Wiring A 4 RJ45 8 pin to Male DB9 RJ45 8 pin to Female DB25 RJ45 8 pin to Male DB25...
Страница 176: ...NPort 6000 Series RADIUS Server F 7 6 Specify your IP address as shown on the following screens...