Configuring Serial Port Operation Modes
7-11
•
Del 1: Data in the buffer will be transmitted after 1 additional byte is received following the
delimiter.
•
Del 2: Data in the buffer will be transmitted after 2 additional bytes are received following the
delimiter.
•
Strip Delimiter: Data in the buffer is first stripped of the delimiter before being transmitted.
Force transmit (default=0 ms): This parameter defines how large a gap in serial communication the NPort
6000 will allow before packing the serial data in its internal buffer for network transmission.
TCP Client Mode
TCP alive check time (default=7 min): This field specifies how long the NPort 6000 will wait for a response
to “keep alive” packets before closing the TCP connection. The NPort 6000 checks connection status by sending
periodic “keep alive” packets. If the remote host does not respond to the packet within the time specified in this
field, the NPort 6000 will force the existing TCP connection to close. For socket and device control modes, the
NPort 6000 will listen for another TCP connection from another host after closing the connection. If TCP alive
check time is set to 0, the TCP connection will remain open even if there is no response to the “keep alive”
packets.
Inactivity time (default=0 ms): This field specifies how long the NPort 6000 will wait for incoming and
outgoing data through the serial port before closing the TCP connection. The TCP connection is closed if there
is no incoming or outgoing data through the serial port for the specified Inactivity time. If this field is set to
0, the TCP connection is kept active until a connection close request is received.
ATTENTION
Inactivity time should at least be set larger than that of Force transmit time. To prevent the unintended
loss of data due to the session being disconnected, it is highly recommended that this value is set large
enough so that the intended data transfer is completed.
Содержание NPort 6000 Series
Страница 20: ...NPort 6000 Series Getting Started 2 2 Panel Layout NPort 6150 6250 NPort 6150 NPort 6250 NPort 6450...
Страница 21: ...NPort 6000 Series Getting Started 2 3 NPort 6610 6650...
Страница 26: ...NPort 6000 Series Getting Started 2 8 NPort 6150 6250 6450 Jumpers NPort 6150 NPort 6250 NPort 6450...
Страница 153: ...NPort 6000 Series Pinouts and Cable Wiring A 4 RJ45 8 pin to Male DB9 RJ45 8 pin to Female DB25 RJ45 8 pin to Male DB25...
Страница 176: ...NPort 6000 Series RADIUS Server F 7 6 Specify your IP address as shown on the following screens...