Module Settings
6-17
Connection control
Connection control
Connect Rule
Disconnect Rule
Modem
Always on/None
Always on after power on
None
Trunk
Periodically
connect/inactivity time
Periodically re-connect (based on the
connection interval setting) to
Modem after power on.
Inactivity time is up
Trunk
Remote host fail/remote
host recovered
Remote Ethernet host has failed. The
NPort 6000 will check the remote
host connection on the Ethernet side
after power on. Once a connection
failure has occurred, data from the
serial device will be sent out through
the Modem.
When the remote Ethernet
host returns to normal, data
will revert to being sent over
Ethernet.