CN2510 

Setting Up Windows Real COM/Linux Real TTY/Unix Fixed TTY 

 

4-42 

3.

 

On the 

General 

page, you can see the server’s 

Serial No.

, and modify 

Server Name

Server IP

, and 

Netmask

. Select the 

Enable 

option (to the right of DHCP)if the network parameters are assigned 

automatically by a DHCP server. 

 

4.

 

On the 

Password 

page, set up a password for this CN2510 for added security. Check the 

Auto Save 

Password on this computer 

box if you want your computer to remember the password. 

 

 

 

 

Содержание CN2510-16

Страница 1: ...CN2510 Async Server User s Manual Edition 7 0 January 2018 www moxa com product 2018 Moxa Inc All rights reserved...

Страница 2: ...to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes no responsi...

Страница 3: ...ing Your Application 3 1 Windows Real COM NT Real COM 3 2 Linux Real TTY Unix Fixed TTY NT Real COM 3 3 Device Control Device Control 3 4 UDP Communication Raw UDP 3 5 Console Management Reverse Termi...

Страница 4: ...10 2 Selecting the Application 10 2 Configuring PPPD PPP Mode 10 4 Configuring SLIPD SLIP Mode 10 6 Configuring Dynamic Mode 10 8 Configuring the Serial Ports 10 12 Configuring Modem Initialization 1...

Страница 5: ...How to Start MxNPortAPI 15 2 MxNPortAPI Function Groups 15 3 Example Program 15 3 A Troubleshooting A 1 Console Terminal Problems A 2 Terminal Port Problems A 4 How to Save CN2510 s Parameters A 4 AS...

Страница 6: ...rver is used to connect terminals modems printers and other asynchronous serial devices to LAN hosts CN2510 complies with TCP IP and IEEE 802 3 specifications using standard Ethernet 10 100BaseT and t...

Страница 7: ...k management Network protocols TCP IP UDP ICMP NetBEUI DHCP Application protocols Telnet Rlogin Rtelnet RAW TCP RAW UDP RCP WINS LPD DNS Multi Host Security protocols RADIUS Dial back PAP CHAP Local u...

Страница 8: ...Indicates serial port transmission Serial Rx Yellow Indicates serial port reception Rear Panel Socket Port Description AC Power Input CN2510 8 and CN2510 8 Automatic detection of 100 240V 47 63 Hz AC...

Страница 9: ...Connecting CN2510 8 16 48V s Power Grounding CN2510 8 16 48V Connecting to the Network Connecting to a Serial Device Connecting to the Console Port Accessing the Console Utility Configuration Checklis...

Страница 10: ...inner holes available for other uses You have two options You can lock either the front or rear panel of the CN2510 to the front of the rack Locking the front panel is shown in the following figure Wi...

Страница 11: ...s power cord to its terminal block follow the steps given below 1 Loosen the screws on the V and V terminals of CN2510 8 16 48V s terminal block 2 Connect the power cord s 48 VDC or 48 VDC wire to the...

Страница 12: ...To connect to the console port use a PC running UNIX or a PC with terminal emulation software e g HyperTerminal or PComm by Moxa parameter settings are baud rate 115200 bps parity check None data bits...

Страница 13: ...Once you know the IP address you can telnet CN2510 over the network to complete the configuration process and to gather information about all servers on the network 1 Run upgrade exe located in the S...

Страница 14: ...hen use search to try locating the server again Using Telnet 1 Telnet over the network to the server s IP address 2 Type 1 to choose ansi vt100 and then press Enter Telnet 192 168 127 254 Async Server...

Страница 15: ...Console from a Console Terminal If you do not know the CN2510 s IP address or it is not possible to use Telnet you can use a direct console connection to enter the CN2510 console Use a terminal emula...

Страница 16: ...CN2510 Getting Started 2 8 3 Select the I Agree option and then click on Next 4 Select a directory in which to install the CN2510 Utility and then click on Next...

Страница 17: ...CN2510 Getting Started 2 9 5 Click on Next to continue 6 Wait while the PComm Lite software is installed...

Страница 18: ...nstallation is complete select Start Programs PComm Terminal Emulator to run PComm Terminal Emulator 9 Use an RJ45 to DB25 female cable to connect to the CN2510 console port Start PComm Terminal and t...

Страница 19: ...COM2 in this example for console connection 115200 for Baud Rate 8 for Data Bits None for Parity and 1 for Stop Bits 11 Click on the Terminal tab and select VT100 for terminal type Press Enter to conf...

Страница 20: ...om the SERVER MENU select Info and then press Enter CN2510 8 CN2510 8_5631 V2 0 SERVER MENU Info Lan Adv Host_table Route_table User_table Quit Examine modify async server basic configuration Enter se...

Страница 21: ...not be found CN2510 sends a query to the Domain Name Server WINS function disable Enable or disable the WINS server The default setting is enable WINS server IP address If a WINS Server is connected t...

Страница 22: ...integer The default value is 192 168 127 254 Async server IP netmask A netmask is used to group network hosts into subnets CN2510 sends TCP IP packets directly to hosts that are on the same subnet If...

Страница 23: ...S key This is a shared key used by the RADIUS protocol If you have a RADIUS server you will need to enter the password in this field UDP port 1 1645 2 1812 RADIUS originally used port 1645 but more re...

Страница 24: ...sses Adding entries to this table gives you the advantage of being able to refer to a host by name instead of by IP address The host table can hold up to 16 Host name Host IP address entries The Host_...

Страница 25: ...m the MAIN MENU use the arrow keys to select Server and then press Enter CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table conf...

Страница 26: ...631 V2 0 Server Port seTting sAve Utility Restart Exit Save current configuration to Flash ROM ESC back to menu Enter select Enter to updated other key to cancel Restart 1 From the MAIN MENU select Re...

Страница 27: ...by using different combinations of operation modes on the same Async Server NOTE Each section title consists of an application name that uses terminology common to our industry followed in parentheses...

Страница 28: ...vered to serial device s connected to CN2510 s serial port s 1 A serial device connected to CN2510 starts transmitting serial data 2 CN2510 converts the data into one or more Ethernet packets 3 The pa...

Страница 29: ...ng CN2510 to access serial devices over an Ethernet network but without needing to modify the software currently in use Moxa also provides Fixed TTY port drivers for Unix environments However the Linu...

Страница 30: ...mission directly set CN2510 for TCP RAW mode Device control applications can use standard Linux Unix Socket programming in Linux Unix environments or WinSock programming in Windows environments Standa...

Страница 31: ...ity is sacrificed for higher transmission speed UDP provides a very powerful transmission method when data needs to be transmitted quickly over the network and upper level application software is give...

Страница 32: ...port for network hosts to initiate a connection RAW mode however does not provide a Telnet conversion function If the serial devices connected to CN2510 need to use the CR LF conversion function then...

Страница 33: ...ts at a remote site with terminal commands transmitted over the network via CN2510 s Ethernet port The Terminal Access application allows you to use fast keys used in many terminal applications and sw...

Страница 34: ...ust first enable Moxattyd to activate the TTY port s mapping function Moxattyd will initiate the connection with the CN2510 and the CN2510 will listen to the connection requests issued by various Moxa...

Страница 35: ...legal access to the network by verifying the user s identity with its Local User Table or RADIUS CN2510 supports PPP SLIP and Terminal modes for dial up dial out access Regardless of which OS is used...

Страница 36: ...xchange services with huge printing demands Use a Windows or Unix host s network printer function via RAW mode and assign a specific IP address and TCP port number to specify the printer s location Yo...

Страница 37: ...multiplex solutions use CN2510 s RTelnet and terminal modes eliminating the need to modify existing software CN2510 acts like a converter by extending the communication distance CN2510s work in pairs...

Страница 38: ...pplications to make the serial ports accessible over an Ethernet but without the need to modify existing serial transmission software The Real COM driver provided by Moxa lets users treat networked se...

Страница 39: ...8 127 254 CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keys...

Страница 40: ...Enter CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM Dis...

Страница 41: ...ach item is described in detail below the figure CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Applic...

Страница 42: ...igure CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify asynchronous port configuration ESC back to menu Enter select Port Speed Bits Stop Parity FIFO RTS CTS XON XOFF Discon...

Страница 43: ...to save and any other key to cancel CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Save current configuration to Flash ROM ESC back to menu Enter select Enter to u...

Страница 44: ...his section we explain how to set up Windows hosts Setting up Windows XP 2003 Hosts In this section we use Windows XP to illustrate the installation procedure The installation procedure for Windows 20...

Страница 45: ...Y Unix Fixed TTY 4 8 4 Wait patiently while the Wizard searches for servers connected to the network 5 The next window to open will ask you if the hardware is connected Select Yes I have already conne...

Страница 46: ...inux Real TTY Unix Fixed TTY 4 9 6 Select Add a new hardware device and then click on Next to continue 7 Select Install the hardware that I manually select from a list Advanced to install the hardware...

Страница 47: ...ens next will ask you to select the type of hardware you are installing Select Multi port serial adapters and then click on Next to continue 9 The window that opens next will ask you to select the dev...

Страница 48: ...dows Real COM Linux Real TTY Unix Fixed TTY 4 11 10 Locate and then select the driver file NPSERVER INF Click on Open to proceed with the installation 11 Select the correct CN2510 model and then click...

Страница 49: ...r copies of the CN2510 model you selected in the previous step 13 Although the next window to open states that the software hasn t passed Windows Logo testing you can rest assured that this driver has...

Страница 50: ...ed automatically or select Manually Enter the IP address of NPort Server Async Server and then enter the IP address of a different server Click on Next to finish installing the CN2510 driver 16 The ne...

Страница 51: ...llation of the server driver This will automatically trigger the port installation procedure Installing Ports 1 After the CN2510 server driver has been installed Windows will notify you that new hardw...

Страница 52: ...ion in the search and then click on Next to continue 3 Although the next window to open states that the software hasn t passed Windows Logo testing you can rest assured that this driver has already be...

Страница 53: ...nux Real TTY Unix Fixed TTY 4 16 4 The driver for Moxa Port 0 will be installed 5 After Moxa Port 0 is installed steps 1 to 4 will be repeated 7 or 15 times depending on whether you are installing dri...

Страница 54: ...ully Configuring CN2510 in a Windows XP 2003 Environment After the CN2510 driver is installed you will be given the option to proceed directly with the configuration of CN2510 You may also configure C...

Страница 55: ...CN2510 Setting Up Windows Real COM Linux Real TTY Unix Fixed TTY 4 18 2 Click on the Configuration tab 3 Click on Settings to configure CN2510 s Basic Configuration Password and Access Control...

Страница 56: ...age modify Server Name IP Address Netmask and Gateway Check the DHCP checkbox if the network parameters will be assigned automatically by a DHCP server 5 On the Password page add a password or change...

Страница 57: ...by IP address In the example shown here the netmask of 255 255 255 255 limits access to the listed IP address 192 168 6 16 To allow access to a group of IP addresses adjust the netmask accordingly To...

Страница 58: ...l COM Linux Real TTY Unix Fixed TTY 4 21 8 Click on Ports Setting to configure the data transmission mode and FIFO for each COM port 9 Check the box es next to the port s you would like to modify and...

Страница 59: ...changed and then click on OK Setting up Windows 2000 Hosts In this section we explain how to set up a host in a Windows 2000 environment Installing a Server 1 Unzip the Windows 2000 driver file locat...

Страница 60: ...COM Linux Real TTY Unix Fixed TTY 4 23 3 When the Welcome to the Add Hardware Wizard window opens click on Next to continue 4 In the Choose a Hardware Task window select Add Troubleshoot a device and...

Страница 61: ...TTY Unix Fixed TTY 4 24 5 In the Choose a Hardware Device window select Add a new device and then click on Next to continue 6 In the Find New Hardware window select No I want to select the hardware f...

Страница 62: ...ux Real TTY Unix Fixed TTY 4 25 7 In the Hardware Type window select Multi port serial adapters from the Hardware types list and then click on Next to continue 8 Click on Have Disk to install from the...

Страница 63: ...p Windows Real COM Linux Real TTY Unix Fixed TTY 4 26 9 After locating the win2k folder select the driver file NPSERVER INF and then click on Open 10 Select the correct CN2510 model and then click on...

Страница 64: ...ically search the network for copies of the CN2510 model you selected in the previous step 12 Although the next window to open states that the software hasn t passed Windows Logo testing you can rest...

Страница 65: ...Unix Fixed TTY 4 28 13 You can select the CN2510 that was located automatically or select Manually Enter the IP address of NPort Server Async Server and then enter the IP address of a different server...

Страница 66: ...Fixed TTY 4 29 14 The next window reports that the driver was installed and port drivers will be installed next Click on Next to continue Installing Ports 1 The ports will be installed automatically...

Страница 67: ...sfully Configuring CN2510 in a Windows 2000 Environment After the CN2510 driver is installed you will be given the option to proceed directly with the configuration of CN2510 You may also configure CN...

Страница 68: ...CN2510 Setting Up Windows Real COM Linux Real TTY Unix Fixed TTY 4 31 2 Click on the Configuration tab 3 Click on Settings to configure CN2510 s Basic Configuration Password and Access Control...

Страница 69: ...page modify Server Name IP Address Netmask and Gateway Check the DHCP checkbox if the network parameters are assigned automatically by a DHCP server 5 On the Password page add a password or change th...

Страница 70: ...igned by IP address In the example shown here the netmask of 255 255 255 255 limits access to the listed IP address 192 168 6 16 To allow access to a group of IP addresses adjust the netmask according...

Страница 71: ...Setting Up Windows Real COM Linux Real TTY Unix Fixed TTY 4 34 8 Click on OK to return to the Configuration page 9 Click on Ports Setting to configure the data transmission mode and FIFO for each COM...

Страница 72: ...Setting 11 Modify the settings that need to be changed and then click on OK Setting up Windows 95 98 ME NT Hosts In this section we explain how to set up a host in a Windows 95 98 ME NT environment Yo...

Страница 73: ...98 ME NT driver file located on the CN2510 CD ROM to your hard disk 2 Locate and run the Setup exe file 3 The setup program is used for both CN2500 and NPort Server Pro products so you will see a Welc...

Страница 74: ...lect a Destination Directory and then click on Next to continue 6 Click on Next to finish installing NPort Pro Manager 7 After the driver is installed NPort Pro Manager and the Add Server Wizard will...

Страница 75: ...Y 4 38 8 Select one of the server s in the list or select No I will define the server myself if the correct server is not listed Click on Next to continue 9 If necessary enter a different IP address i...

Страница 76: ...39 10 Select the COM number for CN2510 s port 1 The rest of the ports will be mapped automatically Click on Next to continue 11 For added security set a password for the CN2510 Check the Auto Saved b...

Страница 77: ...4 40 12 Check the new server settings to make sure they are correct and then click on Finish 13 The server and ports will be displayed in the NPort Server Manager window Click the Save icon in the up...

Страница 78: ...CN2510 or configure CN2510 at a later time In this section we explain how to configure Real COM Mapping 1 Start the Manger by clicking on Start Properties NPort Server NPort Server Manager and then cl...

Страница 79: ...odify Server Name Server IP and Netmask Select the Enable option to the right of DHCP if the network parameters are assigned automatically by a DHCP server 4 On the Password page set up a password for...

Страница 80: ...s Control page allows you to set up access rights for each of the CN2510 s ports Access right is assigned by IP address 6 The Transmission page lets you to select a Transmission Mode and Tx FIFO for e...

Страница 81: ...ting Up Windows Real COM Linux Real TTY Unix Fixed TTY 4 44 8 The Advanced page allows you to add routes to CN2510 However since CN2510 has a column to set the Default Gateway you can ignore this conf...

Страница 82: ...so use ASPP mode provided exclusively by Moxa to communicate with CN2510 For both Linux Unix Socket programming and Windows WinSock programming IP is used to communicate between hosts and devices At t...

Страница 83: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 84: ...keys to select Device Control and then press Enter CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port App...

Страница 85: ...ing data from the serial device Follow these steps to configure ports for ASPP mode 1 Move the cursor to the Mode column for the port and press Enter CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcom...

Страница 86: ...e modify the operation mode of async ports ESC back to menu Enter select Port Application Mod 01 NT Real COM AS TCP data port 950 02 NT Real COM AS TCP command port 966 03 NT Real COM AS TCP alive che...

Страница 87: ...ync Server Proprietary Protocol 02 NT Real COM ASPP Async Server Proprietary Protocol 03 NT Real COM ASPP Async Server Proprietary Protocol 04 NT Real COM ASPP rver Proprietary Protocol 05 NT Real COM...

Страница 88: ...From the MAIN MENU select Port and then press Enter CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server ports configuration Enter select ES...

Страница 89: ...ble Route_table User_table Quit Examine modify async server basic configuration Enter select ESC previous menu Warning You had modified the configuration without saving Would you save it now Y yes N n...

Страница 90: ...baud rate parity etc 5 sio_baud fd baud mode configure serial port s baud rate 6 sio_flowctrl fd mode configure hardware and or software flow control 7 sio_lctrl fd mode line control 8 sio_lstatus fd...

Страница 91: ...ding the file name and other variables ASPP Examples for Windows 1 Program testing environment 2 This program works like a dumb terminal It sends all characters pressed on the keyboard to a remote con...

Страница 92: ...retransmit packets when data is missing UDP is an ideal transmission method if you need fast data transmission and upper layer application software is given the task of checking data for transmission...

Страница 93: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 94: ...ss Enter CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM...

Страница 95: ...e figure Begin End Port serial to LAN Dest IP addr 1 Dest IP addr 2 Dest IP addr 3 Dest IP addr 4 LAN to serial Src IP addr 1 Src IP addr 2 Src IP addr 3 Src IP addr 4 Local Listen Port Delimiter 1 He...

Страница 96: ...d the time required to transfer one character is 10 bits 1200 bits s 1000 ms s 8 3 ms Therefore you should set the Force Transmit timeout to be greater than 8 3 ms The Force Transmit timeout is specif...

Страница 97: ...otes Speed 50 bps to 921 6 Kbps Transmission rate Bits 5 6 7 8 Data bits Stop 1 1 5 2 Stop bits Parity None Even Odd Mark Space Odd Even Mark Space FIFO Yes No First In First Out Device RTS CTS Yes No...

Страница 98: ...r to updated other key to cancel Restart 1 From the MAIN MENU select Restart CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Restart the whole system or selected as...

Страница 99: ...ow how to use CN2510 to connect terminals to a computer over an Ethernet network The following topics are covered in this chapter Accessing the Console Utility Selecting the Application Configuring RT...

Страница 100: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 101: ...the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM Disable Server Proprietary Protocol 02 NT Real COM Dialin out Server Proprietary Prot...

Страница 102: ...ure TCP port 4006 Source IP address Destination IP addr Inactivity time 0 minutes Map keys CR LF to CR LF Authentication type none TCP alive check time 0 minutes Setting Value Notes Necessity TCP port...

Страница 103: ...s for Port Speed Bits Stop Parity FIFO RTS CTS XON XOFF and Discon ctrl for each serial port Each item is described in detail below the figure CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Q...

Страница 104: ...other key to cancel CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Save current configuration to Flash ROM ESC back to menu Enter select Enter to updated other ke...

Страница 105: ...es are supported ASCII terminal with up to 8 simultaneous sessions and Binary terminal with one session for one user Terminals can be connected directly to one of CN2510 s RS 232 ports or connected fr...

Страница 106: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 107: ...sync ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM Disable Server Proprietary Protocol 02 NT Real COM Dialin out Server Proprietary Protocol 03 NT Real COM Ter...

Страница 108: ...mode of async ports ESC back to menu Enter select Port Application Mode Description more setting 01 NT Real COM ASPP Async Server Proprietary Protocol 02 NT Real COM ASPP Async Server Proprietary Pro...

Страница 109: ...gram termination Optional Auto link protocol None Telnet Rlogin None Do not connect to the host automatically Telnet Connects to the host automatically by Telnet Rlogin Connects to the host automatica...

Страница 110: ...rsor to the Mode column for the port and press Enter CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Ap...

Страница 111: ...k by input IP Disable Secondary host IP Auto login prompt ogin Password prompt assword Login user name Login password Terminal type ansi Inactivity time 0 minutes Authentication type local TCP alive c...

Страница 112: ...uired local Check the ID stored in the User_table defined under the SERVER MENU Server Check the ID with the external RADIUS server Refer to Appendix C for RADIUS installation information Optional TCP...

Страница 113: ...Notes Speed 50 bps to 921 6 Kbps Transmission rate Bits 5 6 7 8 Data bits Stop 1 1 5 2 Stop bits Parity None Even Odd Mark Space Odd Even Mark Space FIFO Yes No First In First Out Device RTS CTS Yes N...

Страница 114: ...er to updated other key to cancel Restart 1 From the MAIN MENU select Restart CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Restart the whole system or selected a...

Страница 115: ...e the connection with the CN2510 and the CN2510 will listen on different TCP ports for connection requests from various Moxattyd Once a connection is established the Terminal server can use hot keys t...

Страница 116: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 117: ...8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM Disable Server Proprietar...

Страница 118: ...Each item is described in detail below the figure Max Sessions 8 Terminal model no VT100 Inactivity time 0 minutes TCP alive check time 0 minutes Session Hot key TCP port Remote IP address 1 A 4001 2...

Страница 119: ...gure CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify asynchronous port configuration ESC back to menu Enter select Port Speed Bits Stop Parity FIFO RTS CTS XON XOFF Discon...

Страница 120: ...other key to cancel CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Save current configuration to Flash ROM ESC back to menu Enter select Enter to updated other key...

Страница 121: ...d c Configuring tty Redirection The following example illustrates how to map and redirect a tty device to a MOXA CN2510 serial port Use vi or any other text editor to add or modify entries in the file...

Страница 122: ...t Applications This section illustrates how to use MOXATTY with a number of different applications Terminal Access To use terminal access the process getty must be activated when the system boots up T...

Страница 123: ...quired to enable your applications to open tty devices Using Moxatty Starting MOXATTY Once you have completed the above settings you can start Follow the steps given below to ensure that MOXATTY is ru...

Страница 124: ...out Access allows LAN hosts to establish connections to other sites The following topics are covered in this chapter Accessing the Console Utility Selecting the Application Configuring PPPD PPP Mode...

Страница 125: ...CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to navigate...

Страница 126: ...N2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real COM Disable Server Prop...

Страница 127: ...Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application Mode DYNAMIC on more setting 01 NT Real COM ASPP PPP rver Proprietary Proto...

Страница 128: ...k IP netmask CN2510 automatically assigns the netmask 255 255 255 255 We recommend leaving this space blank Optional TCP IP compression Yes No Depends on whether the remote user s application requests...

Страница 129: ...ration mode of async ports ESC back to menu Enter select Port Application Mode DYNAMIC on more setting 01 NT Real COM ASPP PPP rver Proprietary Protocol 02 NT Real COM ASPP PPPD rver Proprietary Proto...

Страница 130: ...k IP netmask CN2510 automatically assigns the netmask 255 255 255 255 We recommend leaving this space blank Optional TCP IP compression Yes No Depends on whether the remote user s application requests...

Страница 131: ...2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application Mode DYNAMIC on more setting 01 NT Real COM ASPP PPP r...

Страница 132: ...nal 5 To configure the TERM_BIN mode parameters move the cursor to the Detail setting column to highlight Description more setting and then press Enter Enable Detail setting TERM_BIN mode yes Term par...

Страница 133: ...o login prompt ogin Send ID information when this prompt is received Optional Password prompt assword Send Password information when this prompt is received Optional Login user name Login ID Optional...

Страница 134: ...pplication requests compression Optional Inactivity time 0 99 minutes Idle time before the port is disconnected automatically If set to 0 minutes the port will not disconnect Optional Link quality rep...

Страница 135: ...s configuration Enter select ESC previous menu 2 From the PORT MENU select Mode and then press Enter CN2510 8 CN2510 8_5631 V2 0 PORT MENU Mode Line mOdem Welcome_MSG Quit Examine modify asynchronous...

Страница 136: ...Enter CN2510 8 CN2510 8_5631 V2 0 PORT MENU Mode Line mOdem Welcome_MSG Quit Modem initialization and dial out setting Enter select ESC previous menu 3 The Modem page has input display fields for Enab...

Страница 137: ...o edit the welcome message 4 Press Esc to return to the PORT MENU Configuring Optional Local User Information Open Server Menu User_Table to configure local user authentication information If you set...

Страница 138: ...N MENU Save When exiting the SERVER MENU you will be prompted to save settings Press Y to save CN2510 8 CN2510 8_5631 V2 0 SERVER MENU Info Lan Adv Host_table Route_table User_table Quit Examine modif...

Страница 139: ...rt the whole system or selected async ports Enter select ESC previous menu 2 Select System and then press Enter to restart the system and terminate the Telnet session CN2510 8 CN2510 8_5631 V2 0 Syste...

Страница 140: ...inting is illustrated for both UNIX and Windows systems The following topics are covered in this chapter Accessing the Console Utility Selecting the Application Configuring RAW PRN Mode Configuring LP...

Страница 141: ...8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Examine modify async server node table configuration Enter select ESC previous menu Use the following keystrokes to naviga...

Страница 142: ...r to confirm CN2510 8 CN2510 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application ption more setting 01 NT Real...

Страница 143: ...c Server Proprietary Protocol 03 NT Real COM ASPP Async Server Proprietary Protocol 04 NT Real COM ASPP rver Proprietary Protocol 05 NT Real COM ASPP RAW PRN rver Proprietary Protocol 06 Printer RAW P...

Страница 144: ...0 8_5631 V2 0 Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async ports ESC back to menu Enter select Port Application Mode Description more setting 01 NT Real COM ASPP Async S...

Страница 145: ...elow the figure Queue name RAW Queue name ASCII Append Form Feed Disable TCP alive check time 0 minu Setting Value Notes Necessity Queue name RAW Text Specify print queue s name in RAW mode Fixed Queu...

Страница 146: ...Notes Speed 50 bps to 921 6 Kbps Transmission rate Bits 5 6 7 8 Data bits Stop 1 1 5 2 Stop bits Parity None Even Odd Mark Space Odd Even Mark Space FIFO Yes No First In First Out Device RTS CTS Yes N...

Страница 147: ...Select System and then press Enter to restart the system and terminate the Telnet session CN2510 8 CN2510 8_5631 V2 0 System Port Quit Restart the Async Server ESC back to menu Enter select Warning Re...

Страница 148: ...name usr lib lpadmin pLaser1 v dev iop1 Redirect the printer spooler to write to pipe iop1 Assumes the printer name is Laser1 execute asprint for Group 01 asprint dev iop1 CN2510 IP address 2048 Start...

Страница 149: ...600 or rw set printer name usr lib lpadmin pLaser1 v dev iop1 Redirect the printer spooler to write to pipe iop1 Assumes the printer name is Laser1 execute asprint for Group 01 asprint dev iop1 CN2510...

Страница 150: ...ib lpadmin pLaser1 v dev iop1 Redirect the printer spooler to write to pipe iop1 Assumes the printer name is Laser1 add one line to etc printcap file Laser1 lp dev iop1 sd u sr spool Laser1 make spool...

Страница 151: ...to a CN2510 Async Server Setting up a Windows NT Host 1 First you need to add TCP IP printing service to your Windows NT 2 Go to Start Settings Control Panel Network Click on the Services tab and the...

Страница 152: ...Up Printer 11 13 7 Click on Start Settings Printers 8 Click on Add Printer to start the Add Printer Wizard 9 Select My Computer and then click on Next to continue 10 In the window that opens next cli...

Страница 153: ...er CN2510 s IP Address and then enter the Print Queue s name Click on OK to continue 13 Select logical printer port for the LPR port you just added The LPF port should be the IP address of the port 14...

Страница 154: ...Select Shared when prompted with questions asking if the printer is to be shared or not and then enter the name of the shared printer 17 Print a test page to verify that the printer is configured cor...

Страница 155: ...ter 11 16 3 A Welcome message will appear Click on Next to continue 4 Select Local printer and click on Next to continue 5 Select Create a new port and then select LPR Port from the drop down list Cli...

Страница 156: ...nd then enter the Print Queue s name Click on OK to continue 7 Select the printer s manufacturer and model name Click on Next to continue 8 Enter the printer s name and select yes if you wish to set t...

Страница 157: ...s asking if the printer is to be shared or not and then enter the name of the shared printer Click on Next to continue 10 You will need to reboot Windows 2000 to enable the printer you just added When...

Страница 158: ...CN2510 Setting Up Printer 11 19 11 If you want to print a test page reboot Windows 2000 select this printer and click on Print Test Page...

Страница 159: ...ost with a multi port serial board and several serial lines and the other connected to external devices In this way the original host can use a TCP IP connection to control serial devices from a remot...

Страница 160: ...127 254 Async Server CN2510 8 Console terminal type 1 ansi vt100 2 vt52 1 3 CN2510 s MAIN MENU will open as shown below Telnet 192 168 127 254 CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTtin...

Страница 161: ...510 s to illustrate NOTE Configure the Host CN2510 s serial ports for RTELNET mode and configure the Device CN2510 s serial ports for TERM_BIN mode Configuring the Host CN2510 Open Port Menu Mode to s...

Страница 162: ...out Server Proprietary Protocol 03 NT Real COM Terminal Server Proprietary Protocol 04 NT Real COM Reverse Terminal Server Proprietary Protocol 05 NT Real COM Device Control Server Proprietary Protoc...

Страница 163: ...of CN2510 s serial ports is mapped to a TCP port To avoid conflicts with the TCP port numbers for CN251 s other serial ports use the default values 4001 for port 1 4002 for port 2 etc Required Source...

Страница 164: ...Enter select ESC previous menu 2 From the PORT MENU select Mode and then press Enter CN2510 8 CN2510 8_5631 V2 0 PORT MENU Mode Line mOdem Welcome_MSG Quit Examine modify the operation mode of async p...

Страница 165: ...mode of async ports ESC back to menu Enter select Port Application Mode Description more setting 01 NT Real COM ASPP Async Server Proprietary Protocol 02 NT Real COM ASPP Async Server Proprietary Pro...

Страница 166: ...al COM ASPP Async Server Proprietary Protocol 05 NT Real COM ASPP Async Server Proprietary Protocol 06 Multiplex TERM_BIN Binary Terminal mode 1 session 07 NT Real COM ASPP Async Server Proprietary Pr...

Страница 167: ...TCP port 23 By default the Telnet TCP port number is set to 23 which is the default TCP port number for Telnet If you need to telnet to this CN2510 serial port set the Telnet TCP port to a different n...

Страница 168: ...cription more setting 01 NT Real COM ASPP Async Server Proprietary Protocol 02 NT Real COM ASPP Async Server Proprietary Protocol 03 NT Real COM ASPP Async Server Proprietary Protocol 04 NT Real COM A...

Страница 169: ...Notes Speed 50 bps to 921 6 Kbps Transmission rate Bits 5 6 7 8 Data bits Stop 1 1 5 2 Stop bits Parity None Even Odd Mark Space Odd Even Mark Space FIFO Yes No First In First Out Device RTS CTS Yes...

Страница 170: ...ter to updated other key to cancel Restart 1 From the MAIN MENU select Restart CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Restart the whole system or selected...

Страница 171: ...dresses with next hops and 2 routing protocols must determine the contents of these tables CN2510 provides easy to use routing functions that support both static routing tables and dynamic RIP1 RIP2 r...

Страница 172: ...or Select item Enter Key Return to previous menu or Close pop up selector Esc Key Shortcut Key Capitalized letter of the word What is RIP RIP Routing Information Protocol is a protocol used widely to...

Страница 173: ...evious menu 2 From the SERVER MENU select Adv and then press Enter CN2510 8 CN2510 8_5631 V2 0 SERVER MENU Info Lan Adv Host_table Route_table User_table Quit Examine modify async server advance confi...

Страница 174: ...able Quit Examine modify async server advance configuration Enter select ESC previous menu 3 Use the tab and arrow keys to move the cursor to configure Gateway Destination Netmask and Metric Each item...

Страница 175: ...nd send the datagram to the default next hop router 203 67 6 254 In this case we should add the default gateway IP address 203 67 6 254 to the routing table as shown in the following figure to handle...

Страница 176: ...ated outside network 203 67 6 In this case add a route entry for the next hop router 203 67 6 252 that delivers requests to network 202 65 66 The metric hop in this case is 2 route hops CN2510 8 CN251...

Страница 177: ...er 203 67 6 254 as the next hop router For this example assume that the PPP source and destination IPs of modems 1 2 3 and 4 are Source IP Destination IP Source IP Destination IP Modem 1 203 67 6 250...

Страница 178: ...er key to cancel CN2510 8 CN2510 8_5631 V2 0 MAIN MENU Server Port seTting sAve Utility Restart Exit Save current configuration to Flash ROM ESC back to menu Enter select Enter to updated other key to...

Страница 179: ...tor Network Monitor Async Monitor Routing and Monitor PPP Trace The following topics are covered in this chapter Ping Monitor Line Network Async Routing PPP Trace Diagnostic Upgrade Upgrading with the...

Страница 180: ...pgrade Quit Ping a host ESC back to menu Enter select Press ESC to cancel PING 192 168 1 3 56 data bytes 64 bytes from 192 168 1 3 icmp_seq 0 time 0 ms 64 bytes from 192 168 1 3 icmp_seq 1 time 0 ms 6...

Страница 181: ...he status of each port CN2510 8 CN2510 8_5631 V2 0 Line Network Async async Setting Routing PPP Trace Quit Monitor asynchronous port connective utilization ESC back to menu Enter select Port Type Idle...

Страница 182: ...ts Sent Sent IP datagram packets SDiscard Sent but discarded IP datagram packets IP statistics Received Received IP datagram packets RDiscard Received but discarded PPP datagram packets ErrHeader Rece...

Страница 183: ...8 CN2510 8_5631 V2 0 Line Network Async async Setting Routing PPP Trace Quit Monitor asynchronous port line status ESC back to menu Enter select Port TXTotalCnt RxTotalCnt TXBuf RXBuf TXAvg RXAvg DTR...

Страница 184: ...th0 192 168 0 0 192 168 2 180 255 255 0 0 1 U 389 lo17 192 168 2 180 0 UH Iface Name of the physical network interface Destination Network or host that the router allows you to connect to Gateway IP A...

Страница 185: ...r selecting the ports that need monitoring press Space to start CN2510 8 CN2510 8_5631 V2 0 Line Network Async async Setting Routing PPP Trace Quit Trace PPP protocol connect messages ESC back to menu...

Страница 186: ...OK Asynchronous port loopback test OK Ethernet port controller test OK Ethernet port 1 controller loopback test OK Ethernet port 1 transceiver loopback test OK 3 Press Esc to restart the system Upgra...

Страница 187: ...t the CN2510 server by clicking the button on the toolbar If the CN2510 server is at a remote site use to add it to the list 3 Specify the new firmware file used to upgrade Click on OK to start 4 When...

Страница 188: ...puter install PComm Lite from the CN2510 CD and then run the program 2 Use an RJ45 DB9 female cable to connect to the console port and then turn on CN2510 Start the PComm Terminal program and then ope...

Страница 189: ...enter the MAIN MENU 6 Use the following keystrokes to navigate CN2510 s console utility Action Key Move Up Down Left Right Arrow Key or Tab Key Jump to next menu or Select item Enter Key Return to pre...

Страница 190: ...2 From the UTILITY MENU select Upgrade and then press Enter 3 Select Console port using XMODEM for Upgrade type and then press Ctrl U to start 4 When you see Start loading file near the bottom of the...

Страница 191: ...e menu bar 6 In the File Transfer window select XModem CheckSum for Protocol and Transmit for Direction and then click on OK The file will be transmitted to the CN2510 7 Locate the upgrade file CN2510...

Страница 192: ...user s home directory and must be owned by that user This file identifies those users who are equivalent to the local user and are given access without needing to enter a password NOTE The file must...

Страница 193: ...via Console port Network host using RCP Host name IP address File name User name Press CTRL U to start 7 In Host name IP address enter the IP address of the UNIX LINUX host 8 In File name enter the C...

Страница 194: ...es of exported file settings Console Terminal or Remote RCP Console Terminal Export 1 Run Start Programs PComm Terminal Emulator Follow the steps given earlier to enter the MAIN MENU 2 From the MAIN M...

Страница 195: ...near the bottom of the screen click on the Port Manager menu 6 Select Port Manager File Transfer from the menu 7 In the File Transfer window select XModem CheckSum for Protocol and Receive for Directi...

Страница 196: ...our etc hosts file in the rhosts file 3 Telnet CN2510 s IP address 4 After entering CN2510 s MAIN MENU select setting Export 5 In the Export via column select Network host using RCP 6 Enter the UNIX L...

Страница 197: ...ile Console Terminal or Remote RCP Console Terminal Import 1 Run Start Programs PComm Terminal Emulator Follow the steps given earlier to enter the MAIN MENU 2 From the MAIN MENU select seTting and th...

Страница 198: ...ar the bottom of the screen click on the Port Manager menu 6 Select Port Manager File Transfer from the menu 7 In the File Transfer window select XModem CheckSum for Protocol and Transmit for Directio...

Страница 199: ...r etc hosts file in the rhosts file 3 Telnet CN2510 s IP address 4 After accessing CN2510 s MAIN MENU select seTting Import In Import via column select Network host using RCP 5 Enter the UNIX LINUX ho...

Страница 200: ...configuration Enter select ESC previous menu 2 From the SETTING MENU select Default and then press Enter CN2510 8 CN2510 8_5631 V2 0 SETTING MENU Export Import Default Quit Load the factory setting E...

Страница 201: ...15 15 Android API Instructions The following topics are covered in this chapter Overview How to Start MxNPortAPI MxNPortAPI Function Groups Example Program...

Страница 202: ...ease refer the MxNPortAPI Function Groups section This MxNPortAPI is layered between the Android application and Android network manager framework This Android library is compatible with Java 1 7 Andr...

Страница 203: ...tRTS setDTR flush read write getBaud getFlowCtrl getIoctlMode getLineStatus getModemStatus getOQueue setBreak Example Program To make sure this API is workable with the device server on an Android pla...

Страница 204: ...t STOP_BITS_1 MxNPort mxNPort NPortList get 0 Get first NPort device try byte buf H e l l o W o r l d mxNPort open open port mxNPort setIoctlMode mode serial parameters setting mxNPort write buf buf l...

Страница 205: ...to various problems you may come across when using CN2510 The following topics are covered in this appendix Console Terminal Problems Terminal Port Problems How to Save CN2510 s Parameters ASPP Port...

Страница 206: ...he display Question How can I restore CN2510 to the factory default settings Solution After entering the Console window select setting Default and then press Enter The CN2510 will be restored to the f...

Страница 207: ...y now Question My application involves connecting the console port of a CISCO router switch to a Moxa Async Server serial port I connect to the CISCO router switch console by Telnet over the network f...

Страница 208: ...TS CTS hardware flow control then the RTS CTS pins should be included In this case a cable with only TxD RxD and GND pins will not work The terminal may be unlocked by pressing Ctrl S Hex Code 0x13 if...

Страница 209: ...trol then the RTS CTS pins should be included In this case cables with only pins 2 3 and 7 will not work Make sure there is no getty or other process using the SLIP port on the remote site RADIUS Prob...

Страница 210: ...lar line to the shell program mk_radius at read_os 1 For example they might appear as follows read_os case ans in 1 clear mk_src echo enter lib directory cd lib echo compiling source program make cd e...

Страница 211: ...rifying user name and password as well as configuring information which details the type of service to deliver to the user for example SLIP PPP Telnet rlogin Moxa CN2510 Async Server supports RADIUS p...

Страница 212: ...s to maintain a single central database against which all remote user authentication takes place This greatly eases the management burden associated with administering large numbers of Dial in users C...

Страница 213: ...UDP port 1 1645 2 1812 1 Enable RADIUS accounting no SNMP community name public SNMP trap server IP address Ethernet IP forwarding no None Routing protocol None RIP 1 RIP 2 TCP retransmission timeout...

Страница 214: ...uto Term SLIP PPP identification 04 Dialin out DYNAMIC Auto Term SLIP PPP identification Enable Detail setting TERM_BIN mode yes Term parameters PPPD mode yes PPP parameters SLIPD mode yes SLIP parame...

Страница 215: ...mpt ogin Password prompt assword Login user name Login password Terminal type ansi Inactivity time 0 minutes Authentication type none TCP alive check time 0 minutes Console Management RADIUS Settings...

Страница 216: ...commercial servers The server is released under the GNU General Public License GPL which means that it is free to download and install FreeRADIUS can be downloaded from the following website http www...

Страница 217: ...ion 1645 Accounting 1646 6 Select Client and the click on Add Enter CN2510 s IP address in the IP address field Enter CN2510 s password in the password field The password corresponds to the RADIUS key...

Страница 218: ...d Remote Access 2 Follow the steps below to install Right click on Server Local to select Configure and Enable Routing and Remote Access Click on Next to continue 3 Select Remote access server and the...

Страница 219: ...CN2510 RADIUS Server B 9 5 Select TCP IP protocol and then click on Next to continue 6 Specify an IP address...

Страница 220: ...CN2510 RADIUS Server B 10 7 Select Yes I want to use a RADIUS server and then click on Next to start using this function...

Страница 221: ...nstall IAS service to use RADIUS with Windows 2003 IAS service will not be installed by default 1 Click on Start Add or Remove Programs Add Remove Windows Components 2 With Windows Components selected...

Страница 222: ...he installation is finished click on Administrative Tools and run Internet Authentication Service The window shown below will open 5 Select NEW RADIUS Client to add a new RADIUS client You will then b...

Страница 223: ...nProtos IcmpInRedirects ifAdminStatus ipInDiscards IcmpInEchos ifOperStatus ipInDelivers IcmpInEchoReps ifLastChange ipOutRequests IcmpInTimestamps ifInOctets ipOutDiscards IcmpTimestampReps ifInUcast...

Страница 224: ...ranslation MIB tcpEstabResets snmpInBadValues AtIfIndex tcpCurrEstab snmpInReadOnlys AtPhysAddress tcpInSegs snmpInGenErrs AtNetAddress tcpOutSegs snmpInTotalReqVars tcpRetransSegs snmpInTotalSetVars...

Страница 225: ...agrams are presented The following topics are covered in this appendix Pin Assignments 10 100BaseTX Port Pin Assignment Console Port Pin Assignment Async RS 232 Port Pin Assignment Cable Wiring 10 100...

Страница 226: ...Signal 1 Tx 2 Tx 3 Rx 6 Rx Console Port Pin Assignment Pin RS 232 1 DSR in 2 RTS out 3 GND 4 TxD out 5 RxD in 6 DCD in 7 CTS in 8 DTR out Async RS 232 Port Pin Assignment Pin RS 232 1 DSR in 2 RTS out...

Страница 227: ...CN2510 Pin Assignments and Cable Wiring D 3 Async RS 232 Port Cable Wiring 8 pin RJ45 to Male DB9 for CN2510 8 pin RJ45 to Female DB9 for CN2510 8 pin RJ45 to Female DB25 for CN2510...

Страница 228: ...ble Wiring D 4 8 pin RJ45 to Male DB25 for CN2510 DB9 and DB25 Connector Pin Assignments DB9 Connector Pin Assignment Male DB9 Connector Female DB9 Connector DB25 Connector Pin Assignment Male DB25 Co...

Страница 229: ...items shown on the LCM panel s 2nd line down cursor scrolls down through a list of items shown on the LCM panel s 2nd line sel select selects the option listed on the LCM panel s 2nd line The buttons...

Страница 230: ...tatus MAC address IP config IP address Netmask Gateway DNS server 1 DNS server 2 D D C C C C C C Serial set Select port Baud rate Data bit Stop bit Parity Flow control Tx Rx fifo Interface Tx Rx bytes...

Страница 231: ...cursor button again to see Even as the third option P a r i t y E v e n Press the down cursor button again to see Space as the fourth option P a r i t y S p a c e Press the down cursor button yet aga...

Отзывы: