CN2510
Setting Up Windows Real COM/Linux Real TTY/Unix Fixed TTY
4-5
3.
Press
ESC
to return to the
PORT MENU
.
Configuring the Serial Ports
Open
Port Menu
Line
to configure serial port settings.
1.
From the
MAIN MENU
, select
Port
, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
MAIN MENU
------------------------------------------------------------------------------
Server
[Port]
seTting sAve Utility Restart Exit
Examine/modify async server ports configuration
Enter: select ESC: previous menu
2.
From the
PORT MENU
, select
Line
, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
PORT MENU
------------------------------------------------------------------------------
Mode
[Line]
mOdem Welcome_MSG Quit
Examine/modify asynchronous port configuration
Enter: select ESC: previous menu
3.
The
Line
page has pop-up selection lists for
Port
,
Speed
,
Bits
,
Stop
,
Parity
,
FIFO
,
RTS/CTS
,
XON/XOFF
, and
Discon. ctrl
for each serial port. Each item is described in detail below the figure.
CN2510-8
CN2510-8_5631 V2.0
------------------------------------------------------------------------------
Mode
[Line]
mOdem Welcome_MSG Quit
Examine/modify asynchronous port configuration
ESC: back to menu Enter: select
Port Speed Bits Stop Parity FIFO RTS/CTS XON/XOFF Discon. ctrl
01 [
115200
] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
02 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
03 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
04 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
05 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
06 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
07 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
08 [115200] [8] [ 1 ] [None ] [yes] [yes] [no ] [None ]
Setting
Value
Notes
Speed
50 bps to 921.6 Kbps
Transmission rate
Bits
5, 6, 7, 8
Data bits
Stop
1, 1.5, 2
Stop bits
Parity
None, Even, Odd, Mark, Space
Odd, Even, Mark, Space
FIFO
Yes, No
First In First Out Device
RTS/CTS
Yes, No
Hardware Flow Control
XON/XOFF
Yes, No
Software Flow Control
Discon. Ctrl
None
DSR off
or
DCD off
will not be interpreted as a
disconnection.
DSR off
DSR off
will be interpreted as a disconnection.
DCD off
DCD off
will be interpreted as a disconnection.
4.
Press
ESC
to return to the
PORT MENU
.