CN2510
Setting Up Multi-host TTY
9-4
Configuring FIXTTY Mode
1.
Move cursor to the
Description/more setting
column and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
------------------------------------------------------------------------------
[Mode]
Line mOdem Welcome_MSG Quit
Examine/modify the operation mode of async ports
ESC: back to menu Enter: select
Port Application
Mode
Description/more setting
01 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
02 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
03 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
04 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
05 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
06 [Multi-Host TTY ] [FIXTTY ] [
Unix fixtty driver mode
]
07 [NT Real COM
] [ASPP
] [Async Server Proprietary Protocol]
2.
The pop-up selector contains input/display fields for
Max. Sessions
,
Terminal model no.
,
Inactivity
time
,
TCP alive check time
, and also
Session
parameters. Each item is described in detail below the
figure.
+------------------------------------------------------+
| Max. Sessions
: [ 8 ]
|
| Terminal model no.
: [VT100
]
|
| Inactivity time
: [0 ] minutes
|
| TCP alive check time : [0 ] minutes
|
| Session Hot key TCP port Remote IP address
|
| 1 [^A] [4001 ] [
]
|
| 2 [^B] [5001 ] [
]
|
| 3 [^E] [6001 ] [
]
|
| 4 [^F] [7001 ] [
]
|
| 5 [^T] [8001 ] [
]
|
| 6 [^U] [9001 ] [
]
|
| 7 [^V] [10001 ] [
]
|
| 8 [^W] [11001 ] [
]
|
+------------------------------------------------------+
Setting
Value
Notes
Necessity
Max. Sessions
1-8
Select the maximum number of simultaneous
sessions that will be allowed for this serial
port.
Optional
Terminal mode no.
Star NT-560+,
NL-5000A,
VT100
CN2510 provides 3 modes that depend on
the connection mode supported by the
terminal.
Optional
Inactivity time
0-99 minutes
Idle time before the port is disconnected
automatically. If set to 0 minutes, the port
will not disconnect.
Optional
TCP alive check time
0-99 minutes
The time period CN2510 waits before
checking if the TCP connection is alive or not.
If no response is received, CN2510 will reset
the port and terminate the connection.
Optional
Session
Hot Key
TCP port
Remote IP
Configure the
Hot key
,
TCP port
, and
Remote IP address
for each session.
3.
Press
Esc
to return to the
PORT MENU
.