CN2510
Setting Up Routing
13-3
RIP is considered an effective solution for small homogeneous networks. For larger, more complicated
networks, transmitting the entire routing table every 30 seconds can bog down the network with a lot of extra
traffic.
RIP 2 is an extension of RIP. Its purpose is to expand the amount of useful information contained in RIP packets,
and to add security elements. RIP version 2 recently became the standard version of RIP, and the original RIP
is no longer in use.
Configuring RIP
Open
Server Menu
Adv.
to configure
Dynamic routing
.
1.
From the
MAIN MENU
, select
Server
, and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
MAIN MENU
------------------
------------------------------------------------------------
[Server]
Port seTting sAve Utility Restart Exit
Examine/modify async server node/table configuration
Enter: select ESC: previous menu
2.
From the
SERVER MENU
, select
Adv
., and then press
Enter
.
CN2510-8
CN2510-8_5631 V2.0
SERVER MENU
------------------
------------------------------------------------------------
Info. Lan
[Adv.]
Host_table Route_table User_table Quit
Examine/modify async server advance configuration
Enter: select ESC: previous menu
3.
Use the Up/Down arrow keys to move the cursor to the
Routing protocol
pop-up selector. Press
Enter
to
see the options. Select
RIP-1
or
RIP-2
. The RIP setting is only for sending packets. For receiving packets,
CN2510 supports both RIP-1 and RIP-2.
CN2510-8
CN2510-8_5631 V2.0
------------------------------------------------------------------------------
Info. Lan
[Adv.]
Host_table Route_table User_table Quit
Examine/modify async server advance configuration
ESC: back to menu Enter: select
RADIUS server IP
[
]
RADIUS key
[ ]
UDP port <1:1645 2:1812> [1]
Enable RADIUS accounting [no ]
SNMP community name
[public
]
SNMP trap server IP address
[
]
+-------+
Ethernet IP forwarding
[no ] |
None
|
Routing protocol
[None ] | RIP-1 |
| RIP-2 |
TCP retransmission timeout
[ ] +-------+: 50 – 60000 ms)
SIO data transfer timeout
[ ] (range: 0 – 1000 ms)
4.
Press
Esc
to return to the
MAIN MENU
.