5.15
Serial Menu
This menu defines the basic settings of serial interface.
This function is only available for devices with option CO or A0
UNIT NUMMER
This parameter defines serial device addresses. The addresses between 11 and 99 can be assigned to the
devices. Addresses with zero are not allowed, there are used as broadcast addresses.
11
Smallest address
…
99
Highest address
SERIAL BAUD RATE
This parameter defines the serial baud rate
0
9600
9600 baud
1
19200
19200 baud
2
38400
38400 baud
SERIAL FORMAT
This parameter defines the bit data format.
0 7-EVEN-1
7 data Parity even 1 Stop
1 7-EVEN-2
7 data Parity even 2 Stops
2 7-ODD-1
7 data Parity odd 1 Stop
3 7-ODD-2
7 data Parity odd 2 Stops
4 7-NONE-1
7 data no Parity 1 Stop
5 7-NONE-2
7 data no Parity 2 Stops
6 8-EVEN-1
8 data Parity even 1 Stop
7 8-ODD-1
8 data Parity odd 1 Stop
8 8-NONE-1
8 data no Parity 1 Stop
9 8-NONE-2
8 data no Parity 2 Stops
SERIAL INIT
This parameter defines the baud rate for the initialization to the user interface OS6.0. With settings larger than
9600 the initialization time can be reduced..
0
NO
Initialization with 9600 baud. Then the device operates with the value selected by the
user.
1
YES
Initialization with the baud rate set by SERIAL BAUD RATE. Then the device operates
with the value selected by the user.