background image

1  Safety first!

Follow the setup instructions!
Safe handling and trouble-free operation of the Sun-
ways Solar Modules requires knowledge of the basic 
safety precautions.

This setup document provides an overview of the 
safe installation and commissioning procedures for 
Sunways Solar Modules.

In addition, the rules and regulations for accident 
prevention applicable for the operating site/plant 
must be observed.

 

Danger of death through electric shock!

Touching live parts can result in death.

All electrical work on the solar generator must be 
carried out by a qualified electrician while observing 
the VDE regulations, national and other regulations.

Due to the series connection of the modules, voltage 
levels may exceed the protective extra-low voltage.

Even with low solar radiation almost the full open-
circuit voltage can be expected in the modules. 
During all installation and wiring work the modules 
must therefore be covered or disconnected from 
the consumer load. Otherwise there is a risk of arc 
formation on lines carrying direct current.

Suitable fall protection must be used when working 
on roof-mounted solar generators.

The standard solar module is a glass/film product and 
must not be walked on due to the risk of breakage.

Protect the front and rear of the solar modules from 
scratching.

2  Your Solar Modules

Your Sunways Solar Modules consist of the following 
components. Only the details relevant for the instal-
lation at the front and rear are shown.

 

1

2

3

6

5

4

Front

Rear

1  Sunways Solar Cells
2  Aluminium profile frame
3  Junction box with connection cable and 

connectors

4  Hole for earthing
5  Mounting hole
6  Connection cables

SETUP

Installation and Operating 
Instructions
Sunways Solar Modules

SM 230M
SM 215L
SM 215M
SM 240M 
SM 210U
SM 235U
SM 170U

English

EN

Содержание SM 230M

Страница 1: ... the full open circuit voltage can be expected in the modules During all installation and wiring work the modules must therefore be covered or disconnected from the consumer load Otherwise there is a risk of arc formation on lines carrying direct current Suitable fall protection must be used when working on roof mounted solar generators The standard solar module is a glass film product and must no...

Страница 2: ...r points drill holes in the long sides see dia gram in section 2 Your Solar Modules The frame is structurally approved for mounting on the long sides Mounting on the short module sides must be avoided The maximum tolerance is 100 mm 100 100 100 100 1000 Insertion systems U shaped profile over the whole long short side are permitted under the following load conditions Short side mounting Mounting r...

Страница 3: ...sure that only connectors of the same polarity can be connected to each other Connecting socket and plug The system is only correctly locked if the locking hooks are recessed flush in the mating piece CAUTION The plug connectors must not be disconnected or connected under load current They may be con nected and disconnected while voltage is present Release the locking mechanism by pressing on the ...

Страница 4: ...ny declares under its sole responsibility that the solar module types listed above meet the requirements of the following standards DIN EN 50178 EN 50081 1 2 EN 50082 1 2 DIN VDE 0101 DIN VDE 0110 and therefore comply with the EC Directives listed above Roland Burkhardt CTO Sunways AG Photovoltaic Technology Macairestraße 3 5 78467 Konstanz Germany Phone 49 0 7531 996 77 0 Fax 49 0 7531 996 77 444...

Отзывы: