Ax350_04a_oi_e.doc / May-18
Seite 26 / 54
5.9
IO-Link Properties
This menu defines the parameters for the display of the two output process data.
This menu is only displayed if the device is equipped with the option IO (IO-Link Modul).
IN1 FACTOR
(Multiplication factor)
This parameter defines the factor the received value is multiplied with.
-99999999
Smallest value
1
Default value
99999999
Highest end value
IN1 DIVIDER
(Dividing factor)
This parameter defines the factor the received value is devided by.
-99999999
Smallest value
1
Default value
99999999
Highest end value
IN1 ADDITIVE VALUE
(Additive value)
This parameter defines the factor the received value is added with.
-99999999
Smallest value
0
Default value
99999999
Highest end value
IN1 DECIMAL POINT
(decimal point)
This setting determines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified location
2 000000.00
Decimal point at the specified location
3 00000.000
Decimal point at the specified location
4 0000.0000
Decimal point at the specified location
5 000.00000
Decimal point at the specified location
6 00.000000
Decimal point at the specified location
7 0.0000000
Decimal point at the specified location
IN1 SCALE UNITS
This parameter defines the required engineering unit. This parameter does not affect the calculation of the display
value. The number of decimal places must be defined with the parameter DECIMAL POINT. A list of available units
can be found in Chapter 6.2 Appendix: Display of scale units.
IN2 FACTOR (multiplication factor for value 2, see IN 1 factor)
IN2 DIVIDER
(
dividing factor for value 2, see IN1 Divider)
IN2 ADDITIVE VALUE
(
additive value for value 2, see IN1 ADDITIVE VALUE)
IN2 DECIMAL POINT
(decimal point for value 2, see IN1 DECIMAL POINT)
IN2 SCALE UNITS
(scale units for value 2, see IN1 SCALING UNITS