Ax350_04a_oi_e.doc / May-18
Seite 35 / 54
5.16
Analog Out Menu
This menu defines the basic settings of the analog output. This function is only available for devices
with option A0.
ANALOG SOURCE
This parameter defines the reference source for the Analog Output
0 INPUT 1
the reference source is input 1
1 INPUT 2
the reference source is input 1
2 LINKAGE 1 – 2
the reference source is the result of the linking of input1 and input 2
3 INPUT 1 TOTAL
the reference source is input 1 with totalization
4 INPUT 2 TOTAL
the reference source is input 1 with totalization
5
LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2 with
totalization
6 IO LINK VALUE 1
the reference source is the process data out value 1 sent by the IO-Link master
7 IO LINK VALUE 2
the reference source is the process data out value 2 sent by the IO-Link master
8 MINIMUM VALUE 1
minimum value, the reference source is input 1
9 MAXIMUM VALUE 1 maximum value, he reference source is input 1
10 MINIMUM VALUE 2
minimum value, the reference source is input 2
11 MAXIMUM VALUE 2 maximum value, he reference source is input 2
The totalization depends on the operation mode. See chart in chapter IN 1 Totalization.
ANALOG FORMAT
This parameter defines the output characteristics. The analogue output is proportional to the display value.
With setting ANALOG FORMAT (-10 … +10 V) in MODE COUNTER the polarity of the analog output depends
on the polarity of the display value.
0
-10…10V
-10 … +10 V
1
0…20MA
0 … 20 mA
2
4…20MA
4 … 20 mA
ANALOG START
This parameter defines the start value of the analog conversion. This start value is corresponding to the
display value for an analog output of 0 V or 0/4 mA.
-99999999
Smallest start value
0
Default value
+99999999
Highest start value
ANALOG END
This parameter defines the end value of the analog conversion. This end value is corresponding to the display
value for an analog output of (+/-) 10 V or 20mA.
-99999999
Smallest end value
10000
Default Wert
+99999999
Highest end value