Ax350_04a_oi_e.doc / May-18
Seite 25 / 54
5.8
Linkage Properties
In this menu the parameters for the linked operation mode are defined. This menu is shown only, if in
GENERAL MENU an operation mode (z.B. IN1 – IN2) with link was selected.
The parameters in Menu IN 1 PROPERTIES and IN 2 PROPERTIES have to be set, before using a linked
operation mode.
The result of the link can be scaled with the following parameters.
FACTOR
This parameter defines the factor, the result of the link will be charged.
-99999999
Smallest value
1
Default value
99999999
Highest end value
DIVIDER
This parameter defines the divider, the result of the link will be charged..
-99999999
Smallest end value
1
Default value
99999999
Highest end value
ADDITIVE VALUE
This parameter defines the additive constant, the result of the link will be charged.
-99999999
Smallest end value
0
Default value
99999999
Highest end value
DECIMAL POINT
This value defines the position of the decimal point.
0 NO
No decimal point
1 0000000.0
Decimal point at the specified position
2 000000.00
Decimal point at the specified position
3 00000.000
Decimal point at the specified position
4 0000.0000
Decimal point at the specified position
5 000.00000
Decimal point at the specified position
6 00.000000
Decimal point at the specified position
7 0.0000000
Decimal point at the specified position
SCALE UNITS
This parameter defines the required engineering unit. This parameter does not affect the calculation of the display
value. The number of decimal places must be defined with the parameter DECIMAL POINT. A list of available units
can be found in Chapter 6.2 Appendix: Display of scale units.