background image

Ax350_04a_oi_e.doc / May-18 

 

Seite 18 / 54 

5.1

 

General Menu 

 

OPERATIONAL MODE  

This parameter specifies the selected measuring function. 
 

0  SINGLE 

Single channel mode, only input 1 

1  DUAL 

Dual channel mode, input 1 and input 2 separated 

2  IN1 + IN 2 

Dual channel mode, sum of input 1 and input 2  

3  IN1 – IN 2 

Dual channel mode, difference of input 1 and input 2  

4  IN1 x IN 2 

Dual channel mode, multiplication of input 1 and input 2  

5  IN1 / IN 2 

Dual channel mode, input 1 divide by input 2  

 

PIN PRESELECTION

 

This parameter defines the PIN-code to lock the quick start of the menu PRESELECTION VALUE for entering the 
preselection values

.

(master PIN 6079).  

This Lock function is only useful in conjunction with active lock function in PIN PARAMETER.

 

 

0000 

No lock  

… 

 

9999 

Access after entering PIN-Code 9999 

 

 

PIN PARAMETER

  

This parameter defines the PIN-code for lock function of all parameters (master PIN 6079).

 

 

0000 

No lock 

… 

 

9999 

Parameterization of the unit after entering PIN-code 9999 

 
 

BACK UP MEMORY 

 

NO 

No back –up by power failure 

YES 

Backup by power failure, actual value will be saved, only by totalization 

 
 

FACTORY SETTINGS 

 

NO 

No default values are loaded 

YES 

Load default values of all parameters (grey marked default values) 

 

Содержание touchMATRIX AX350

Страница 1: ...display inclusively icons and units Intuitive and easy parameterization by plain text and touchscreen 24 V auxiliary output for encoder supply Totalization for each input Linearization with 24 contro...

Страница 2: ...inor changes and fixes AX350_3a_oi cn Okt 17 Expansion of the scale units AX350_4a_oi sn April 18 Extension with IO link Legal notices All contents included in this manual are protected by the terms o...

Страница 3: ...ion RL 12 3 11 IO Link Option IO 13 4 Display and touch screen 14 4 1 Screen structure for parametrization 14 4 2 Screen structure in operation 15 5 Parameter Overview Menu Structure 16 5 1 General Me...

Страница 4: ...erves the right to modify the hardware software or operation manual at any time and without prior notice Therefore there might be minor differences between the unit and the descriptions in operation m...

Страница 5: ...e cross sections for wiring are described in the Technical Specifications Before first start up it must be ensured that all connections and wires are firmly seated and secured in the screw terminals A...

Страница 6: ...ed in the parameter menu The device can be set to one of the following operation modes SINGLE single channel operation of input 1 DUAL two channel operation of input 1 and 2 IN 1 IN 2 two channel oper...

Страница 7: ...Ax350_04a_oi_e doc May 18 Seite 7 54 2 2 Function diagram...

Страница 8: ...d at the auxiliary voltage output All GND terminals are internally interconnected 3 2 Auxiliary Voltage Output Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders The outpu...

Страница 9: ...put or current input can be set in the Menu IN 1 IN 2 PROPERTIES Important Before connecting the sensor the configuration voltage or current input must be set Wiring of the intrecmental inputs Voltage...

Страница 10: ...contacts When exceptionally mechanical contacts are used please connect an external capacitor between GND and the corresponding input A capacity of 10 F will reduce the input frequency to 20 Hz and m...

Страница 11: ...andard Sub D 9 connector Connection of the RS232 interface Connection of the RS485 interface 3 8 Control Output Option AO AR CO CR Four control outputs are available at terminal 20 21 22 and 23 Switch...

Страница 12: ...tput Devices with option AC can also be supplied with a DC voltage between 18 and 30 VDC at terminals 1 and 2 3 10 Relay Output Option RL Two relay outputs with potential free changeover contacts are...

Страница 13: ...LINK PROPERTIES Display for analog sensors and data transmission of 6 input process data 32 Byte 6 input process data are sent to the IO link master cyclically The following values are submitted Value...

Страница 14: ...Select the parameter menu via arrow buttons and confirm with OK The menu selection can be terminated with C Parameter selection Select the parameter via arrow buttons and confirm with OK The parameter...

Страница 15: ...line display with unit and status bar To switch to the next display press the touch screen Control or Relay status are only shown with Option AO CO RL Two line display To switch to the next display pr...

Страница 16: ...ACTORY SETTINGS IN 1 PROPERTIES CONFIGURATION START VALUE END VALUE DECIMAL POINT SCALE UNITS SAMPLING TIME AVERAGE FILTER OFFSET LINEARIZATION TOTALIZATION IN 1 LINEARIZATION P1 X P1 Y P2 X P2 Y P23...

Страница 17: ...UP DELAY 2 EVENT COLOR 2 PRESELECTION 3 MENU SOURCE 3 MODE 3 HYSTERESIS 3 PULSE TIME 3 OUTPUT TARGET 3 OUTPUT POLARITY 3 OUTPUT LOCK 3 START UP DELAY 3 EVENT COLOR 3 Menu Parameter PRESELECTION 4 MEN...

Страница 18: ...defines the PIN code to lock the quick start of the menu PRESELECTION VALUE for entering the preselection values master PIN 6079 This Lock function is only useful in conjunction with active lock funct...

Страница 19: ...end value 10000 Default value 99999 Highest end value DECIMAL POINT This value defines the position of the decimal point 0 NO No decimal point 1 0000000 0 Decimal point at the specified position 2 000...

Страница 20: ...numbers of floating average cycles 4 16 numbers of floating average cycles OFFSET This parameter defines the zero offset tara of the input This parameter does not affect the TOTALIZATION function 99...

Страница 21: ...P24 X X coordinate of the linearization point This value representing the display value which the unit show in the display without linearization 99999999 Smallest X coordinate 0 Default value 99999999...

Страница 22: ...AL 1 for the operation function at the control input see Command Menu DIVIDER This parameter defines the devisor for the totalization 0 1 No division 1 10 The result of the totalization is divided by...

Страница 23: ...value of input 2 at 10 V or 20 mA see IN 1 Properties DECIMAL POINT Position of the decimal point see IN 1 Properties SCALE UNITS The displayed units see IN 1 Properties SAMPLING TIME S Sampling inte...

Страница 24: ...P1 Y P24 Y Y coordinate of the linearization point see IN 1Linearization 5 7 IN 2 Totalization The totalization function is defined in this menu TIME BASE The time base of the totalization see IN 1 To...

Страница 25: ...E VALUE This parameter defines the additive constant the result of the link will be charged 99999999 Smallest end value 0 Default value 99999999 Highest end value DECIMAL POINT This value defines the...

Страница 26: ...mal point 0 NO No decimal point 1 0000000 0 Decimal point at the specified location 2 000000 00 Decimal point at the specified location 3 00000 000 Decimal point at the specified location 4 0000 0000...

Страница 27: ...er the following conditions This function is only available for devices with option CO AO or RL SOURCE 1 This parameter defines the reference source for PRESELECTION 1 0 INPUT 1 the reference source i...

Страница 28: ...ndition is applied Display value PRESELECTION 1 HYSTERESIS 1 OFF Display value PRESELECTION 1 HYSTERESIS 1 OFF 3 RESULT PRES Display value is greater or equal PRESELECTION 1 e g overspeed With HYSTERE...

Страница 29: ...2 OUTPUT POLARITY 1 Polarity for the switching condition of preselection 1 0 ACTIVE HIGH Switching condition is true Active HIGH 1 ACTIVE LOW Switching condition is true Active LOW OUTPUT LOCK 1 Latch...

Страница 30: ...switching condition of preselection 2 See chapter PRESELECTION 1 MENU OUTPUT TARGET 2 Assignment of an output or relay for the switching condition of preselection 2 See chapter PRESELECTION 1 MENU ex...

Страница 31: ...T TARGET 3 Assignment of an output or relay for the switching condition of preselection 3 See chapter PRESELECTION 1 MENU see PRESELECTION 1 MENU 3 CTRL OUT 3 Assignment of switching conditions at Ctr...

Страница 32: ...ECTION 1 MENU OUTPUT TARGET 4 Assignment of an output or relay for the switching condition of preselection 4 See chapter PRESELECTION 1 MENU except default value see PRESELECTION 1 MENU 4 CTRL OUT 4 A...

Страница 33: ...bit data format 0 7 EVEN 1 7 data Parity even 1 Stop 1 7 EVEN 2 7 data Parity even 2 Stops 2 7 ODD 1 7 data Parity odd 1 Stop 3 7 ODD 2 7 data Parity odd 2 Stops 4 7 NONE 1 7 data no Parity 1 Stop 5...

Страница 34: ...e time in seconds for cycling transmission of SERIAL VALUE when using the serial output On a serial request the cycling transmission is stopped for 20 s 0 000 All cyclic transmission is switched off T...

Страница 35: ...he reference source is input 1 9 MAXIMUM VALUE 1 maximum value he reference source is input 1 10 MINIMUM VALUE 2 minimum value the reference source is input 2 11 MAXIMUM VALUE 2 maximum value he refer...

Страница 36: ...20 4 mA when the ANALOG END value is reached e g 95 00 corresponds to a conversion of 9 5 V or 18 mA when the ANALOG END value is reached 0 00 Smallest gain 100 00 Default value 110 00 Highest gain AN...

Страница 37: ...see chapter Screen structure in operation d 12 RESET MIN MAX Reset the Min Max values d s 13 CLEAR LOOP TIME N A 14 ACTIVATE N A 15 STORE DATA N A 16 TESTPROGRAM N A 17 SET RED COLOR Red display Even...

Страница 38: ...e start display after switching on the device 0 Single Single line display The source must be defined in SOURCE SINGLE 1 Dual The sources must be defined in SOURCE DUAL TOP DOWN SOURCE SINGLE Referenc...

Страница 39: ...e 0 INPUT 1 the reference source is input 1 1 INPUT 2 the reference source is input 2 2 LINKAGE 1 2 the reference source is the result of the linking of input1 and input 2 3 INPUT 1 TOTAL the referenc...

Страница 40: ...center 2 Viewing angle from bottom SCREEN SAVER S This parameter defines the time in seconds until the display is switched off after the last touch action A new touch action will activate the display...

Страница 41: ...T AD1 AD2 C1 C2 ENQ EOT control character Hex 04 AD1 unit address High Byte AD2 unit address Low Byte C1 register code High Byte C2 register code Low Byte ENQ control character Hex 05 The following ex...

Страница 42: ...11 W 12 kW 13 VA 14 mm 15 cm 16 m 17 inch 18 feet 19 C 20 F 21 K 22 1 sec 23 1 min 24 1 h 25 gal min 26 Pa 27 kPa 28 29 Edit Unit A customized unit with up to 16 digits can be edited using this parame...

Страница 43: ...99999999 99999999 0 23 IN 1 LINEARIZATION P1 Y A1 0 99999999 99999999 0 24 IN 1 LINEARIZATION P2 X A2 0 99999999 99999999 0 25 IN 1 LINEARIZATION P2 Y A3 0 99999999 99999999 0 26 IN 1 LINEARIZATION P...

Страница 44: ...9 0 63 IN 1 LINEARIZATION P21 Y E1 0 99999999 99999999 0 64 IN 1 LINEARIZATION P22 X E2 0 99999999 99999999 0 65 IN 1 LINEARIZATION P22 Y E3 0 99999999 99999999 0 66 IN 1 LINEARIZATION P23 X E4 0 9999...

Страница 45: ...P11 Y I9 0 99999999 99999999 0 112 IN 2 LINEARIZATION P12 X J0 0 99999999 99999999 0 113 IN 2 LINEARIZATION P12 Y J1 0 99999999 99999999 0 114 IN 2 LINEARIZATION P13 X J2 0 99999999 99999999 0 115 IN...

Страница 46: ...2 FACTOR N6 0 99999999 99999999 1 159 IO LINK PROPERTIES IN2 DEVIDER N7 0 99999999 99999999 1 160 IO LINK PROPERTIES IN2 ADDITIVE VALUE N8 0 99999999 99999999 0 161 IO LINK PROPERTIES IN2 DECIMAL POIN...

Страница 47: ...3 R8 0 0 1 0 201 PRESELECTION 3 MENU OUTPUT LOCK 3 R9 0 0 1 0 202 PRESELECTION 3 MENU START UP DELAY 3 S0 0 0 1 0 203 PRESELECTION 3 MENU EVENT COLOR 3 90 0 0 3 0 204 PRESELECTION 3 MENU __ 91 0 0 0...

Страница 48: ...INPUT 2 ACTION V0 0 0 26 0 237 COMMAND MENU INPUT 2 CONFIG V1 0 0 3 2 238 COMMAND MENU INPUT 3 ACTION V2 0 0 26 0 239 COMMAND MENU INPUT 3 CONFIG V3 0 0 3 2 240 COMMAND MENU __ V4 0 0 0 0 241 COMMAND...

Страница 49: ...55 TARA INPUT 2 56 TARA INPUT 1 2 57 RESET TOTAL 1 58 RESET TOTAL 2 59 RESET TOTAL LINKAGE 60 TEACH PRESELECTION 1 61 TEACH PRESELECTION 2 62 TEACH PRESELECTION 3 63 TEACH PRESELECTION 4 64 SCROLL DI...

Страница 50: ...g diagram The parameters P1 X to P24 X are used to specify the coordinates on the x axis These are the measuring values that the unit normally would generate according to the actual input signal Now e...

Страница 51: ...ntity P01_x P10_x P15_x P16_x Pressure Sensor 0 20 mA P01_x P10_x P16_x P01_y P07_y P15_y P16_y Pressure Volume P15_x P10_y To solve the problem we divide the non linear part of the tank into 14 parts...

Страница 52: ...Ax350_04a_oi_e doc May 18 Seite 52 54 6 5 Dimensions Dimension in mm inch...

Страница 53: ...tion Accuracy 2 current or voltage operation 10 10 V Ri 50 kOhm 0 20 mA 4 20 mA Ri 100 Ohm 16 bit 0 1 Control inputs Number of inputs Format Frequency Load 3 HTL PNP Low 0 3 V High 9 30 V max 10 kHz m...

Страница 54: ...stive touchscreen Housing Material Mounting Dimensions w x h x d Cut out w x h Protection class Weight ABS UL 94 V 0 panel 96 x 48 x 116 mm 3 78 x 1 89 x 4 56 inch 91 x 43 mm 3 58 x 1 69 inch IP65 fro...

Отзывы: