Diagnostics D-11
DCP501 Installation Manual
In-Band Data Activity Indicator
−−−−
LED and OSD
The in-band data activity indicator lights when the DCP501 is receiving a message. The
indicator is blank when you enter this diagnostic and three seconds after receiving the last
message. The indicator covers all packet processors regardless of which stream they are
monitoring.
Table D-6 lists the LED and OSD indications:
Table D-6
In-band data activity
LED OSD Status
Off
blank
No data received
On
* Data
received
EMM Data Activity Indicator
−−−−
LED and OSD
Table D-7 lists the LED and OSD indicator lights when the DCP501 is receiving a message on
the EMM stream. The indicator is clear when entering this diagnostic.
Table D-7
EMM data activity indicator
−−−−
LED and OSD
LED OSD Status
off
blank
No data received
on
* Data
received
Carrier Lock
−−−−
LED and OSD
This diagnostic indicates that the digital in-band receiver is locked to the carrier.
Table D-8 lists the LED and OSD indications:
Table D-8
In-band carrier lock
−−−−
LED and OSD
LED OSD Status
L
YES Carrier
locked
U
NO Carrier
unlocked
A
Analog Analog
channel
PCR Lock
−−−−
OSD Only
The PCR lock indicates a program-clock-reference lock with the current digital data stream.