D-6 Diagnostics
DCP501 Installation Manual
Table D-3 lists the error codes:
Table D-3
Error codes
Initialization status errors
Error Code
OSD
Cause
Remedy
E 00*
NO ERROR
Indicates normal condition after
initialization
Not applicable
E 01*
NOT CONNECTED DCP501 did not receive a connect
message
Send a connect message
Restore out-of-band signal
E 02
PWR CYCLE
Init Error
Box needs a Power Cycle
to recover
E 03
DRAM
DRAM error
Not used at this time
E 04
DPSRAM
DP-SRAM error
Not used at this time
E 07
ROM
ROM verification failure
Power cycle box; if
repetitive, return for repair
E 08
RAM
Faulty RAM, ROM, EEPROM, or
POST failure (this is a hardware
failure)
Return DCP501 for repair
E 09
BATTERY
Dead battery or memory has not been
initialized; occurs if battery fails to
keep the RAM alive during
power-down; causes DCP501 to be
disconnected
Return DCP501 for repair;
requires factory
initialization message
E 10
SERIALNO
Invalid serial number
Not used at this time
E 11
UNIT ADDRESS
Invalid unit address
Return DCP501 for repair;
requires a unit creation
message
E 12
POST
POST failed
Not used at this time
E 13
BOOT
Sys_boot initialization failure
Power cycle box; if
repetitive, return for repair
E 14
STARTUP
DCP501 system startup failure
Power cycle box; if
repetitive, return for repair
E 15
TSI INVALID
TSI structure is corrupted
Power cycle box; if
repetitive, return for repair
E 16
FLASH BAD
NUMBER
Bad flash number specified for Initiate
Flash Platform
Error logged, ignore
E 17
BAD PLATVAL
Bad platform validation step number
Error logged, ignore
*E 00 and E 01 cannot be displayed while the DCP501 is off. The other errors will display on the LED
display when the DCP501 is off.