Installation and Replacement
3-11
Configuring the Serial Interface
V.35/V.36, and X.21/
V.11 Interface
Types
Use this procedure to set the Interface Options parameter for V.35, V.36, and
X.21/V.11 interface types:
Step
Action
Result/Description
1
From the Control Terminal
Port Main menu, select
Configure -> Port
.
The Port record appears.
2
In the Port Number
parameter, type
3
, then press
ENTER.
Port 3 is selected.
3
In the Port Type parameter,
type
FRI
, then press ENTER
This defines Port 3 type as FRI.
4
In the Interface Type
parameter, type one of these
interfaces:
V.35, V.36, X.21
and then press ENTER.
The interface is set to the selected type.
5
In the Interface Options
parameter, type a
?
, and then
press ENTER.
The Range and Default appears:
Range = NONE, XOVER
Default = NONE
Specify the cable type:
NONE - V35/V.36/X.21 DCE with
straight through cable
XOVER - V35/V.36/X.21 DCE with
crossover adapter cable
6
Select either
NONE
for
straight DCE mode, or
XOVER
when using the
DTE crossover adapter cable.
When NONE is selected, the serial interface
is in straight DCE mode.
When XOVER is selected, the serial
interface is in DCE Mode using the adapter
cable.
Содержание 49901 - Vanguard 340 Router
Страница 1: ...Vanguard Managed Solutions Vanguard 340 and 340 Enhanced Installation Manual ...
Страница 10: ......
Страница 16: ...xvi Varning Varning är den mest allvarliga beteckningen och den indikerar att du kan skadas fysiskt ...
Страница 18: ......
Страница 20: ......
Страница 106: ......
Страница 114: ......
Страница 116: ......