background image

About the Vanguard 340 and 340 Enhanced 

1-7

Features and Functionality

Operating Software 

The Vanguard Applications Ware software is compressed in FLASH memory and 
loaded into the SDRAM DIMM for operation. The Vanguard 340 and 340 Enhanced 
support the following Applications Ware packages:

• IP

+

 Applications Ware Package (includes IP, and IPX)

• SNA

+

 Applications Ware Package (includes IP, and SNA)

• Multi-Service Applications Ware Package.

See the 

Software Release Notice 

accompanying your Vanguard unit for more 

information on the software license upgrades available for the Vanguard 340 and 340 
Enhanced.

Содержание 49901 - Vanguard 340 Router

Страница 1: ...Vanguard Managed Solutions Vanguard 340 and 340 Enhanced Installation Manual ...

Страница 2: ...ocured for use by the Department of Defense the following legend applies Restricted Rights Legend Use duplication or disclosure by the Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 If the software is procured for use by any U S Government entity other than the Department of Defense the fo...

Страница 3: ...Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations This is a Class B product Operation of this equipment in a residential environment may cause radio interference in which case the user may be required to take adequate measures to correct the interference at his her own expense This product was verified under test conditions that included th...

Страница 4: ...ain uninterrupted service If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information If your home has specially wired alarm equipm...

Страница 5: ... Private Networks 1 15 Branch Office to Central Office over Public or Private Networks 1 16 SOHO and Branch Office to Central Office over ISDN 1 18 Vanguard 340 and 340 Enhanced DSL and G SHDSL 1 20 G SHDSL Daughtercard 1 21 Clocking Limitations 1 22 Chapter 2 Hardware Description Enclosures 2 2 Motherboards 2 4 Vanguard Daughtercards 2 9 Chapter 3 Installation and Replacement Checking Your Shipme...

Страница 6: ...1 Installing Removing the Lithium Battery 3 33 Chapter 4 Powering Up and Loading Software Powering Up Your Vanguard 340 and 340 Enhanced 4 2 Powering Off The Vanguard 340 and 340 Enhanced 4 3 Powerup Diagnostics 4 5 Accessing the Control Terminal Port 4 7 Alternative Methods for Accessing the CTP 4 8 Obtaining and Installing Operating Software 4 9 Appendix A Specifications Appendix B Software Lice...

Страница 7: ...nded for people who install and operate the Vanguard 340 and 340 Enhanced How to Use This Manual The following table describes the contents of this manual This Chapter Description Chapter 1 Vanguard hardware and software features Chapter 2 Description of the hardware features and components Chapter 3 Installing and replacing hardware including daughtercards and motherboard Chapter 4 Powerup proced...

Страница 8: ...ocols Part Number T0102 Multi Service Feature Protocols Part Number T0103 Multimedia Feature Protocols Part Number T0104 Alarms and Reports Manual Part Number T0005 Software Installation and Coldloading Manual Part Number T0028 IP and LAN Feature Documentation Set IP and LAN Feature Protocols Part Number T0100 SNA Feature Documentation Set SNA Feature Protocols Part Number T0101 Serial Feature Doc...

Страница 9: ...ailable at the time of release The Vanguide CD ROM is shipped with each Vanguard product To order an additional copy of the Vanguide CD ROM please contact a VanguardMS Representative VanguardMS Web Site Check the VanguardMS web site for the latest documentation http www vanguardms com support documentation ...

Страница 10: ......

Страница 11: ...are or data Warning Warning is the most serious notice indicating that you can be physically hurt Simplified Chinese Danish Særlige overskrifter Følgende overskrifter fremhæver nogle af oplysningerne i vejledningen De tjener hvert et specifikt formål og vises i følgende format Bemærk Bemærk anvendes til at fremhæve vigtig information Forsigtig Forsigtig understreger oplysninger som hvis de ikke bl...

Страница 12: ... tietoja Kullakin on oma erikoistarkoituksensa ja ne esitetään seuraavassa muodossa Huomaa Huomautusta käytetään korostamaan tärkeätä tietoa Vaara Vaarailmoitus antaa tietoa jonka huomiotta jättäminen voi johtaa ohjelmiston laitteiston tai tietojen vahingoittumiseen Varoitus Varoitus on kaikkein vakavin ilmoitus ja se kertoo mahdollisesta loukkaantumisriskistä French Messages spéciaux Les messages...

Страница 13: ...ren kann Warnung Eine Warnung weist Sie darauf hin daß ernsthafte Körperverletzungsgefahr besteht Italian Simboli speciali I seguenti simboli ciascuno con una speciale funzione evidenziano determinate informazioni all interno del manuale Il formato è quello riportato qui di seguito Nota Questo tipo di avvertimento viene utilizzato per evidenziare tutte le informazioni significative relative ad una...

Страница 14: ...nadstype har en spesiell hensikt og vises på følgende format Merk Merk brukes for å fremheve viktig informasjon Forsiktig Forsiktig gir deg informasjon om situasjoner som kan føre til skade på programvare datamaskin eller data dersom den blir fulgt Advarsel Advarsel er den mest alvorlige merknaden og indikerer at du kan bli fysisk skadet ...

Страница 15: ...a información de la guía Todas tienen un propósito especial y se muestran con el formato siguiente Nota Las notas se utilizan para destacar determinada información de importancia Advertencia Las advertencias le proporcionan información que debe seguirse si no desea que el software el hardware o los datos puedan verse dañados Aviso Los avisos son las notificaciones de carácter más importante e indi...

Страница 16: ...xvi Varning Varning är den mest allvarliga beteckningen och den indikerar att du kan skadas fysiskt ...

Страница 17: ...is website for product sales support documentation or training information http www vanguardms com Comments About This Manual To help us improve our product documentation please complete the comment card included with this manual and return it by fax to 508 339 9592 If you prefer provide your name company and telephone number and someone in the documentation group will contact you to discuss your ...

Страница 18: ......

Страница 19: ...___________________________________________________________________________ What information if any is missing from the document _________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ...

Страница 20: ......

Страница 21: ... 340 and 340 Enhanced Overview Introduction This chapter describes the hardware and software functions and the target applications for Vanguard 340 products These topics are discussed Vanguard 340 and 340 Enhanced Descriptions Features and Functionality Target Applications ...

Страница 22: ...Frame Relay and Voice over IP Virtual Private Network VPN Broadband access 10 100BT LAN G SHDSL DCC 3 DES SIMM Interface External Power supply 62945 01 APS Model APS61ES 30 340 G SHDSL Limitation There is a limitation on available memory in the 340 that does not allow you to run G SHDSL and Voice at the same time This is caused by the 4M flash limit in 340 This limitation does not apply to the Van...

Страница 23: ...nced are SNMP manageable and are available with a variety of LAN SNA and IP networking features The Vanguard 340 and 340 Enhanced support two Vanguard Daughtercard slots for video voice fax and mixed protocol data traffic such as IP Frame Relay X 25 ISDN or NX64 T1 E1 services Note For descriptions of the daughtercards and other hardware components refer to the appropriate sections in Chapter 2 Ha...

Страница 24: ...and support for two Vanguard Daughtercards 50 Mhz MPC860T PowerPC processor 4 Megabytes of Non Volatile FLASH on board 4 to 8 Megabytes FLASH SIMM optional 16 Megabytes of SDRAM DIMM expandable to 32 Megabytes optional Standard rear panel ports include Two daughtercard ports One serial interface DB25 port supporting V 24 V 35 V 36 V 11 X 21 interfaces One Async RJ 45 connector Control Terminal Por...

Страница 25: ...l AD 748U 3125A External Power Supply The Vanguard 340 and 340 Enhanced use a different external power supply The external power supply for 340 Enhanced 62749 03 cannot be used on the Vanguard 340 or 342 The Vanguard 340 External Power Supply 62945 01 can be used on the 340 Enhanced 10 100BaseT Ethernet Cable Port 5 is a10 100BaseT Ethernet Port that conforms to the Fast Ethernet specification IEE...

Страница 26: ...ents listed below as factory installed or as separate add in daughtercards FXS FXO Voice Voice FXS 4 Port FXS 4 Port FXO FT1 FE1 Dual E M RemoteVU Video ISDN BRI U Data ISDN enhanced ISDN BRI S T Data ISDN BRI Voice DSU ECC DIM V 90 G SHDSL Note Release 6 2 or greater software is required for the V 90 Release 6 3 and greater supports the enhanced ISDN BRI ST Data Daughtercard Release 6 4 or greate...

Страница 27: ...operation The Vanguard 340 and 340 Enhanced support the following Applications Ware packages IP Applications Ware Package includes IP and IPX SNA Applications Ware Package includes IP and SNA Multi Service Applications Ware Package See the Software Release Notice accompanying your Vanguard unit for more information on the software license upgrades available for the Vanguard 340 and 340 Enhanced ...

Страница 28: ...ons for the Vanguard 340 and 340 Enhanced These examples are shown are for the 340 and 340 Enhanced Virtual Private Network IP and Serial Protocols over Frame Relay Video and Serial Protocols over Public or Private Networks Branch Office to Central Office over Public or Private Networks SOHO and Branch Office to Central Office over ISDN DSL G SHDSL ...

Страница 29: ...gh separate tunnels across the same infrastructure A VPN allows network protocols to traverse incompatible infrastructures A VPN also enables traffic from many sources to be differentiated so that it can be directed to specific destinations and receive specific levels of service Advantages of a VPN A VPN provides following advantages Cost Effectiveness Infrastructure Cost By using a VPN a company ...

Страница 30: ...cations at a very competitive price point Hardware based Encryption and Compression Data Encryption and Compression Data encryption is a very CPU intensive process and is therefore best implemented on hardware The VanguardMS solution provides a secure hardware based encryption and compression on a single module Figure 1 1 shows an example of a secure hardware based VPN solution for a site to site ...

Страница 31: ...About the Vanguard 340 and 340 Enhanced 1 11 Target Applications Figure 1 1 Hardware based VPN Solution for Site to Site Applications Remote Site Remote Site Central Site Internet or IP Network ...

Страница 32: ...D5 and Secure Hashing Algorithm 1 SHA 1 for data integrity 340 Enhanced ISAKMP supports DES Triple DES and AES ESP support DES Triple DES and AES Note ISAKMP and ESP support is available with the ECC DIMM on the Vanguard 340 Enhanced Multi protocol Tunneling and Encryption General Router Encryption GRE Whereas IPSec can only tunnel IP traffic over IP Networks GRE tunneling is a Layer 2 protocol th...

Страница 33: ...and VanguardMS Proprietary SAM key exchange protocol to negotiate the keys Figure 1 2 Encryption over IP Frame Relay and X 25 Networks Security Features The security features in Vanguard Applications Ware release 5 5 and greater also include Firewall functionality based on IP Packet Filtering Access Control Lists can be configured based on a combination of source and destination addresses IP Proto...

Страница 34: ...me relay as specified by RFC 1490 As shown in Figure 1 3 a SNA cluster controller connects to a serial port on the Vanguard 340 and the Ethernet LAN connects to the 10 100BaseT Ethernet port The Vanguard is fully interoperable with third party routers via RFC 1490 Figure 1 3 IP and Serial Protocols over Frame Relay Frame Relay FEP Ethernet Ethernet Vanguard 340 Cluster Controller Terminals Host Th...

Страница 35: ...d Bank Machines ABMs With Dial on Demand software feature enabled the Vanguard 34x initiates a connection only when there is a data transfer that is only for the duration of a bank transaction The RemoteVU Daughtercard can capture video and send video streams to the central bank s security system Figure 1 4 Video and Serial Protocols over Public or Private Networks Automated Teller Machine Vanguar...

Страница 36: ...x is equipped with a T1 daughtercard supports connectivity to the network at fractional T1 speeds Figure 1 5 Vanguard 34x supporting Voice Video and ISDN over a Public or Private Network Security Monitoring Vanguard 34x Equipped with RemoteVU Daughtercards IP FR X 25 Video Camera 7330 PC s Running Host Video Workstation Application Ethernet ISDN Vanguard 34x Equipped with DIM FXS FXO and ISDN Daug...

Страница 37: ...the central office PBX This eliminates long distance telephone charges between the branch and central office ISDN Backup link between Branch and Central Office DSU DIM FXS FXO and ISDN Daughtercards To provide an alternative path in case of network failure you can configure and connect serial ports to an external analog modem or switch 56K DSU As Figure 1 5 illustrates you can also configure ISDN ...

Страница 38: ... offices or telecommuting employees working from a home office A dial in or dedicated ISDN link provides network connection for the home and branch as shown in Figure 1 6 Figure 1 6 Small Home and Branch Office to Central Office Application 7330 ISDN Ethernet Branch Office Central Office PBX Internet Ethernet Ethernet Small Home Office Vanguard 34x Equipped with FXS FXO and ISDN Daughtercards Vang...

Страница 39: ...Vanguard supporting the FXS FXO and ISDN daughtercard a work at home employee can stay fully connected to the corporate backbone and PBX via an ISDN link A telecommuter can easily access file servers email servers voice mail and the Internet from home The Voice Over IP VoIP software feature provides voice support Branch Office FXS FXO and ISDN Daughtercard Small branch offices can access the corpo...

Страница 40: ... the downstream direction Network speeds can reach 27 Mbps but this is an aggregate amount of bandwidth that is shared by users Few computers will be capable of connecting at such high speeds so a more realistic number is 1 to 3 Mbps In the upstream direction speeds can be up to 10 Mbps Most modem producers have selected a more optimum speed between 500 Kbps and 2 5 Mbps Figure 1 7 LAN Over WAN DS...

Страница 41: ...SL Daughtercard is supported in either of the two daughtercard slots For information on the G SHDSL Daughtercard reference the G SHDSL Manual Part Number T0100 14 Installation instructions are available in the Daughtercard Installation Guide Part Number T0020 340 G SHDSL Limitation There is a limitation on available memory in the 340 that does not allow you to run G SHDSL and Voice at the same tim...

Страница 42: ... is connected to a SDB2 card on a Vanguard 6560 which is configured as EXT clocked the link will not come up Workaround Configure the Vanguard 6560 SDB2 port as INT clocked and the Vanguard 34x as EXT clocked Connect the ports with a crossover cable The DIM on the Vanguard 6560 SDB2 port should be in the DCE position Vanguard 34x DCE EXTLP VG6560 SDB2 or SDB INT When a Vanguard 34x Port 3 is confi...

Страница 43: ...Hardware Description 2 1 Chapter 2 Hardware Description Overview Introduction This chapter describes the Vanguard 340 and 340 Enhanced Enclosuress Motherboards Vanguard Daughtercards ...

Страница 44: ... standard 19 inch equipment rack bracketed to the underside of a desktop or vertical surface The enclosure contains a motherboard and two optional daughtercards Front Panel The front panel of the Vanguard 340 and 340 Enhanced see Figure 2 1 includes 10 LEDs that provide node status Reset button For a full description of all Front panel LEDs and reset button refer to the Powerup Diagnostics section...

Страница 45: ...Note For information about port numbering and cabling refer to the Port Characteristics and Cabling section in Chapter 3 Caution Do not connect Ports 4 or 5 to the Public Communications Network Serial Number The Hardware Serial Number indicates the version of hardware in your unit This serial number label is located on the rear panel of the Vanguard router Refer to this serial number when contacti...

Страница 46: ...s of Non Volatile FLASH on board and has 16 Megabytes of SDRAM synchronous DRAM on an attached DIMM These components are included on the motherboard Connectors for FLASH expansion 4 Megabyte SIMM on board SDRAM Expansion 16 Megabyte DIMM standard Data Compression Encryption SIMM optional Two Vanguard Daughtercard slots Fan A battery that provides power for the unit s real time clock 10 100BaseT Et...

Страница 47: ...abytes of SDRAM October 2004 and later 16 Megabytes of SDRAM synchronous DRAM on an attached DIMM was available before October 2004 These components are included on the motherboard Connectors for FLASH expansion 8 Megabyte SIMM on board AES Encryption Slot ECC DIM Two Vanguard Daughtercard slots Battery SDRAM DIMM Slot 2 Daughtercard Slots Data Compression Encryption SIMM Slot Flash SIMM Slot Fan ...

Страница 48: ...ol Terminal Port RJ 45connector DB 25 Connector Figure 2 4 shows the location of the 340 Enhanced motherboard components Figure 2 4 Vanguard 340 Enhanced Motherboard Vanguard Daughtercard Slots SDRAM Slot FLASH SIMM Slot Battery 10 100 BaseT Ethernet Port Control Terminal Port CTP DB25 DCE Power Supply Connector AES Encryption ECC DIMM Slot ...

Страница 49: ...face that is installed on the motherboard The serial interface can be configured to function as a Digital Interface Module allowing the support of these interfaces on Port 3 only V 24 V 35 V 36 V 11 X 21 For information on configuring the serial interface refer to the Configuring the Serial Interface section in Chapter 3 The serial interface supports only DCE It can accommodate DTE with the use of...

Страница 50: ...incorrect FLASH SIMM module could result in damage to the SIMM device or your Vanguard Product Please see the list below for the memory device that is compatible with your hardware platform Vanguard 340 Enhanced and 342 Compatible FLASH SIMM Devices are as follows 8 Meg FLASH Devices PN IW 388DL3 R 120 PN CT8M8FJV120 M1M Vanguard 340 Compatible FLASH SIMM Devices are as follows 4 Meg FLASH Devices...

Страница 51: ...and Enhanced ISDN BRI S T Data ISDN BRI S T Voice DSU V 90 G SHDSL ECC DIMM The following section briefly describes these cards For instructions for installing these cards refer to the Vanguard Daughtercard Installation Guide Part Number T0020 Daughtercard Compatibility Older Vanguard Daughtercards do not fit into the Vanguard 340 or 340 Enhanced You can only use the newer daughtercards which are ...

Страница 52: ... RJ11 connectors for FXS and FXO Ports However only one port can be active at a time Figure 2 6 shows the FXS FXO Voice Daughtercard connectors as they appear on the back panel Figure 2 6 1 port FXS FXO Voice Daughtercard Connector 2 Port Voice FXS The Dual FXS Daughtercard provides two FXS interface ports and support one voice channel each The 2 Port Voice FXS Daughtercard has two RJ11 connectors...

Страница 53: ...rcard connectors as they appear on the back panel Figure 2 9 FXO Daughtercard Note Only one 4 Port card can be installed in the Vanguard 340 Enhanced Choose either daughtercard slot 1 or slot 2 The Vanguard 340 Enhanced supports six voice ports Any combinations of the cards below are supported 1 Quad FXO or FXS plus 1 Dual FXO or FXS or 1 Single FXO or FXS FT1 FE1 The FT1 FE1 Daughtercards allow t...

Страница 54: ...ansport of video images over low bandwidths as low as 2 4 kbps It is ideal for applications such as security surveillance and remote monitoring The daughtercard has three ports RJ 45 connector for camera controls such as pan tilt zoom BNC connector the primary video input from a single camera 8 Pin Mini DIN connects to a custom cable that terminates in three BNC connectors When its video ports are...

Страница 55: ...erface It conforms to ITU I 430 is LAPD ITU Q 921 compliant and supports Integral X 31 Q 931 dial support NI1 5ESS DMS 100 ETSI Euro Numeric switch types D Channel Packet Mode Leased Circuit Services I Interface Permanent B for German Monopol support or Japan High Speed Digital Figure 2 14 shows the ISDN BRI S T Daughtercard connectors as they appear on the back panel Figure 2 14 ISDN and Enhanced...

Страница 56: ...15 ISDN BRI Voice Daughtercard Connectors Note For more information on supported daughtercard configurations refer to the Daughtercard Installation Manual Part Number T0020 Chapter Five DSU The DSU Daughtercard provides an RJ48S connector and can support speeds of 56 kbps synchronous It conforms to AT T 62310 point to point and multipoint and to ANSI T1 E1 4 91 006 56 kbps The card supports the fo...

Страница 57: ...he 3460 Fast R User s Guide Part Number T0022 01 Figure 2 18 shows the rear panel connectors on the V 34 modem daughtercard Figure 2 18 V 34 Daughtercard Connector V 90 Modem The V 90 modem daughtercard provides dial back up for a customers PPP Async applications The V 90 uses a dual RJ 11 for connection to central offices PBXs or telephone systems V 90 is designed for the Vanguard 320 and 34x The...

Страница 58: ...L Daughtercard For information on the G SHDSL Daughtercard reference the G SHDSL Manual Part Number T0100 14 Installation instructions are available in the Daughtercard Installation Guide Part Number T0020 Figure 2 20 G SHDSL Daughtercard Connector Note There is a limitation on available memory available in the 340 that does not allow you to run G SHDSL and Voice at the same time This is caused by...

Страница 59: ...ow to install cable and modify your Vanguard 340 and 340 Enhanced device Instructions are provided for the following tasks Checking Your Shipment Contents Installing the Vanguard 340 and 340 Enhanced Configuring the Serial Interface Cabling the Vanguard 340 and 340 Enhanced Modifying Your Vanguard 340 and 340 Enhanced ...

Страница 60: ...side Serial interface adapter cable optional External Power Supply and Cable Warning The Vanguard 340 and 340 Enhanced use a different external power supply The external power supply for 340 Enhanced 62749 03 cannot be used on the Vanguard 340 The Vanguard 340 External Power Supply 62945 01 can be used on the 340 Enhanced Note A Rack Mounting Kit must be purchased separately Figure 3 1 Vanguard 34...

Страница 61: ...ecting and Preparing the Installation Site Installing Your Vanguard 340 and 340 Enhanced Thermal Considerations Configuring the Serial Interface Port Characteristics and Cabling Daughtercard Cable Information Modifying Your Vanguard 340 and 340 Enhanced After your Vanguard 34x is installed and cabled go to the Powering Up Your Vanguard 340 and 340 Enhanced section in Chapter 4 for instructions on ...

Страница 62: ... sur les équipements de protection contre la foudre Si vous avez des problèmes engendrés par des surtensions dues à la foudre installez des protections contre les surintensités appropriées sur les lignes d alimentation et de données connectées à votre produit Vanguard Vorsicht Alle Vanguard Produkte sollten in für Computer und elektronische Geräte geeigneten Umgebungen verwendet werden In durch Bl...

Страница 63: ...keine Gegenstände auf dem Gerät plazieren Zu den Entlüftungsöffnungen der Vorderabdeckung sollte ein Abstand von 2 5 cm und zur Rückseite des Gerätes von 30 5 cm eingehalten werden Figure 3 2 Proper Cable and Air Clearance Caution Do not place items weighing more than 20 pounds 9 kg on top of a Vanguard 34x enclosure Do not block the top vents of the unit Minimum 0 5 inches on either side for vent...

Страница 64: ...section on page 3 22 3 Be sure that the four rubber feet are on the bottom of the enclosure 4 Attach the power cord and cables to the rear panel 5 Place the enclosure in the selected site and power unit on Do not block the fan inlet or outlet vents Refer to the Powering Up Your Vanguard 340 and 340 Enhanced section in Chapter 4 6 If you have a Vanguard 340 ensure the fan is operational after power...

Страница 65: ... check that the fan is working properly The feet must be installed and air should be blowing out of the unit Note The Vanguard 340 Enhanced does not include a fan in the unit Inlet Temperature After the unit is running check the ambient air temperature Make sure it does not exceed the operating temperature limits specified in Appendix A Power Supply Shutdown If the Vanguard 34x power supply is not...

Страница 66: ... accommodate DTE with the use of a crossover adapter cable For information on DTE capability refer to the Setting the Interface Options section on page 3 10 The Serial Interface Parameters The serial interface is supported in the Port Configuration menu and can be configured using the Control Terminal Port CTP Included in the Port Configuration menu are two parameters that allow you to set both th...

Страница 67: ...rs 2 In the Port Number parameter type 3 then press ENTER Port 3 is selected 3 In the Port Type parameter type FRI then press ENTER This defines Port 3 type as FRI 4 In the Interfaced Type type a and then press ENTER The Range and Default appear Range V 24 V 35 V 36 X 21 NONE Default V 24 Specify the Electrical Interface Type V 24 V 24 Electrical Interface Type V 35 V 35 Electrical Interface Type ...

Страница 68: ...arame ter type 3 then press ENTER Port 3 is selected 3 In the Port Type parameter type FRI then press ENTER This defines Port 3 type as FRI 4 In the Interface Type parameter type V 24 and then press ENTER The interface is set to V 24 5 In the Interface Options parameter type a and then press ENTER The Range and Default appears Range RI TM Default RI Specify the Pin 22 option RI V 24 uses Pin 22 fo...

Страница 69: ...defines Port 3 type as FRI 4 In the Interface Type parameter type one of these interfaces V 35 V 36 X 21 and then press ENTER The interface is set to the selected type 5 In the Interface Options parameter type a and then press ENTER The Range and Default appears Range NONE XOVER Default NONE Specify the cable type NONE V35 V 36 X 21 DCE with straight through cable XOVER V35 V 36 X 21 DCE with cros...

Страница 70: ...board in place are tight If the screws are loose the motherboard could loosen under the weight of the cables and cause damage to the equipment Vanguard 340 and 340 Enhanced Rear Panel Figure 3 3 illustrates the rear panel of the Vanguard 340 and 340 Enhanced optional daughtercards and the locations of cables that must be connected Figure 3 3 Vanguard 340 and 340 Enhanced Rear Panel and Cable Conne...

Страница 71: ...kbps Selectable DIM Site Daughtercard DSU EIM Cable Assembly and Lease Line Telco Cable Part Number shipped with Integral DSU only DSU 56 kbps DTE DSU RJ48S DSU Daughtercard DSU Telco Cable Part Number shipped with DSU Daughtercard DSU 56 kbps DTE DSU RJ11 FXS FXO Daughtercard RJ11 to RJ11 Cable N A N A RJ45 ISDN U or S T Daughtercard RJ45 to RJ45 Cable Either 56 or 64 kbps for each B Channel and ...

Страница 72: ...DTE DSU RJ48S DSU Daughtercard DSU Telco Cable shipped with DSU Daughtercard DSU 56 kbps DTE DSU RJ11 FXS FXO Daughtercard RJ11 to RJ11 Cable N A N A BNC video connectors RemoteVU Daughtercard BNC to BNC Cable N A N A RJ45 RemoteVU Daughtercard RJ45 to RJ45 Cable N A N A RJ11 Dual FXS Daughtercard RJ11 to RJ11 Cable N A N A RJ48C FT1 Daughtercard RJ48 to RJ48 Twisted Pair Cable full or fractional ...

Страница 73: ...es For daughtercard installation and more cable information please refer to the Vanguard Daughtercard Installation Guide Part Number T0020 RJ45 G SHDSL Daughtercard RJ45 to RJ45 Cable N A N A 3 DB25 V 11 V 24 V 35 V 36 DIM DB25 to DB25 Cable V 11 V 35 and V 36 Max sync speed 2 mpbs V 24 Max sync speed 80 kpbs Max async speed 115 2 kbps Selectable Adapter Cable required for DTE 4 RJ45 CTP Port RJ45...

Страница 74: ...r Note If you plan to use a personal computer to configure the Vanguard 34x you may need to purchase a DB25 male to DB9 female adapter for the serial port of your personal computer The serial ports on most personal computers require DB9 connectors The connector pins are numbered as indicated in Figure 3 4 Figure 3 4 RJ45 Pinout RJ45 Pin Signal Pin Connection on DB25F Adapter 1 not connected Reques...

Страница 75: ...J45 to RJ45 Color Gray Part Number 61798 01 Port 5 Connector Pinout The 10 100BaseT Ethernet Port has a single RJ45 connector and is cabled using CAT 5 twisted pair copper cables This table details the pin for the 10 100Base T RJ45 connector Cabling Daughtercards Pin Signal Pin Signal 1 Transmit Positive 5 Not Used 2 Transmit Negative 6 Receive Data Negative 3 Receive Data Positive 7 Not Used 4 No...

Страница 76: ...ttached modem pin 25 on the modem comes into the 6500 on this pin For more information on configuring the V 24 interface type refer to the Setting the Interface Type section on page 3 9 Port3 Pin DCE Signal Function Signal Name Port3 Pin DTE Signal using Crossover Adapter Cable Function Signal Name 1 PROTECTIVE GROUND 1 PROTECTIVE GROUND 2 TRANSMITTED DATA 2 TRANSMITTED DATA 3 RECEIVED DATA 3 RECE...

Страница 77: ...dapter Cable Function Signal Name 1 PROTECTIVE GROUND 1 PROTECTIVE GROUND 2 TRANSMITTED DATA A 2 TRANSMITTED DATA A 3 RECEIVED DATA A 3 RECEIVED DATA A 4 REQUEST TO SEND 4 REQUEST TO SEND 5 CLEAR TO SEND 5 CLEAR TO SEND 6 DATA SET READY 6 DATA SET READY 7 SIGNAL GROUND 7 SIGNAL GROUND 8 DATA CARRIER DETECT 8 DATA CARRIER DETECT 14 TRANSMITTED DATA B 14 TRANSMITTED DATA B 15 TRANSMITTED CLOCK A 15 ...

Страница 78: ...using Crossover Adapter Cable Function Signal Name 1 PROTECTIVE GROUND 1 PROTECTIVE GROUND 2 TRANSMITTED DATA A 2 TRANSMITTED DATA A 3 RECEIVED DATA A 3 RECEIVED DATA A 4 CONTROL A 4 CONTROL A 5 no connection 5 no connection 6 INDICATION B 6 INDICATION B 7 SIGNAL GROUND 7 SIGNAL GROUND 8 INDICATION A 8 INDICATION A 14 TRANSMITTED DATA B 14 TRANSMITTED DATA B 15 SIGNAL ELEMENT TIMING A 15 no connec...

Страница 79: ...r cable connections for DCE to DCE mode Figure 3 5 Crossover Cable Connections Ordering Cables To order cables please contact a Vanguard Managed Solutions representative In addition to the crossover adapter cables these cables can also be ordered DB25 Male to M34 Female cable DB25 Male to M34 Male cable DCE 2 3 4 8 6 20 17 24 DCE 2 3 4 8 6 20 17 24 ...

Страница 80: ...40 and 340 Enhanced Introduction You can modify your Vanguard 34x by adding or replacing components on the motherboard This section explains how to make these modifications and includes the following topics Installing Vanguard Daughtercards Accessing the Motherboard Installing Removing the Lithium Battery ...

Страница 81: ...r to the Vanguard Daughtercard Installation Guide Part Number T0020 for complete daughtercard installation instructions Caution On site installation of these daughtercards should be undertaken by trained service technicians Mise en Garde L installation de ces cartes fille optionnelles doit être effectuée par des techniciens expérimentés Vorsicht Die Installation vor Ort dieser optionalen Zusatzkar...

Страница 82: ...am Gerät zu verhindern schalten Sie das Gerät ab und ziehen Sie den Netzstecker aus bevor Sie die Hauptplatine entfernen oder installieren Caution Use care when handling and placing the motherboard on a surface There are components on the bottom of the motherboard that can be damaged Mise en Garde Soyez prudents lorsque vous manipulez la carte mère ou la placez sur une surface Il y a des composant...

Страница 83: ...ten keinen elektrostatischen Entladungen ausgesetzt werden durch die interne Bauteile beschädigt werden können Wenden Sie die entsprechenden Maßnahmen zur Erdung und zum Schutz vor statischen Ladungen bei der Handhabung von Karten und Komponenten an Figure 3 6 Vanguard 340 Motherboard Removal and Replacement Example Handle Screws ...

Страница 84: ...ove the power cord and cables from the back of the unit 2 Remove the two screws on either side of the chassis at the rear of the unit 3 Use the handle on the right side of the front panel to carefully slide out the motherboard 4 Place the motherboard on a clean flat surface Step Action 1 Carefully slide the motherboard into the card guides within the opening 2 Push the motherboard into the enclosu...

Страница 85: ...ellement placer un SIMM dans une rainure SIMM erronée ce qui pourrait endommager l équipement Vorsicht Die Steckplätze für die Komprimierungs und Verschlüsselungs SIMMs und für die Flash SIMMs können verwechselt werden Vergewissern Sie sich dass Sie die SIMMs in die richtigen Steckplätze einsetzen Ansonsten können Sie Ihr System beschädigen Caution Some components used in the 34x are sensitive to ...

Страница 86: ... remove a FLASH SIMM 1 At a slight angle insert the SIMM into connector U181 as shown in Figure 3 7 2 Carefully press the SIMM down pushing the locking tabs through the holes The clips click into place 3 To remove the SIMM use your fingers to push back the two metal retaining clips and lift out the SIMM Adding Removing Data Compression Encryption SIMM To add and remove a Data Compression Encryptio...

Страница 87: ...llation and Replacement 3 29 Modifying Your Vanguard 340 and 340 Enhanced Figure 3 7 SIMM and DIMM Installation Replacement SDRAM DIMM Data Compression Encryption SIMM FLASH SIMM Locking levers Locking tabs ...

Страница 88: ...ots Figure 3 8 shows the locations of the Vanguard 340 SIMM and DIMM slots SDRAM DIMM Slot U173 FLASH SIMM Slot U181 Data Compression Encryption SIMM Slot J39 Battery SDRAM DIMM Slot 2 Daughtercard Slots Data Compression Encryption SIMM Slot Flash SIMM Slot Fan Connector 10 100 BaseT Ethernet Port Control Terminal Port CTP DB25 DCE Power Supply Connector ...

Страница 89: ...se steps to add and remove an ECC DIMM 1 At a slight angle insert the SIMM into the connector lining up the holes with the AES Encryption slot as shown in Figure 3 9 2 Carefully press the SIMM down pushing the locking tabs through the holes The clips click into place 3 Lock the SIMM into place with the locking levers 4 To remove the SIMM use your fingers to push back the two metal retaining clips ...

Страница 90: ... Your Vanguard 340 and 340 Enhanced Figure 3 9 ECC DIMM Installation Vanguard Daughtercard Slots SDRAM Slot FLASH SIMM Slot Battery 10 100 BaseT Ethernet Port Control Terminal Port CTP DB25 DCE Power Supply Connector AES Encryption ECC DIMM Slot ...

Страница 91: ...ité Warnung Die in diesem Abschnitt aufgeführten Vorgänge sollten ausschließlich von qualifiziertem Servicepersonal durchgeführt werden Wenn die Batterie unsachgemäß installiert wird kann sie nach dem Einschalten des Vanguard Produkts explodieren und das Gerät beschädigen Note After installing the battery set the Vanguard 34x s date and time This is done via the CTP in the Update System Parameter ...

Страница 92: ...attery Retaining Tabs Battery Holder Battery To remove the battery Using your fingers push the retaining tabs aside and pry the battery out of the holder To install the battery Place the battery in the holder with the positive side up and press down until the retaining tabs click into place Note When done replace the motherboard as explained in the Accessing the Motherboard section on page 3 24 ...

Страница 93: ... and Loading Software Overview Introduction This chapter describes Powering Up Your Vanguard 340 and 340 Enhanced Powering Off The Vanguard 340 and 340 Enhanced Powerup Diagnostics Accessing the Control Terminal Port Obtaining and Installing Operating Software ...

Страница 94: ...oes not have a power switch on the unit Use these steps to power on the device 1 Plug the DC output cable of the power supply into the power socket on the Vanguard 34x back panel 2 Connect the power cord to the power supply outlet Resetting the 34x The RESET button resets the node Pressing the RESET button is the equivalent of a power up operation which clears all existing calls and brings down al...

Страница 95: ...Never disconnect or reconnect the power connector from the Vanguard back panel if the power supply is still connected to the AC power outlet Figure 4 2 Doing so can potentially damage the Vanguard unit Figure 4 1 Approved Practice for Powering Down a Vanguard Unit Figure 4 2 Unacceptable Practice for Powering Down or Powering Up a Vanguard Unit AC Power Outlet Power Cord Power Connector AC Power O...

Страница 96: ...er supply Des tensions dangereuses provenant des réseaux de télécommunication peuvent être présentes sur des unités qui ne sont pas reliées à la terre Déconnectez tous les câbles de télécommunication avant de retirer le câble de secteur du bloc d alimentation An nicht geerdeten Geräten können gefährliche Spannungen vom Telekommunikationsnetz anliegen Trennen Sie alle Kabelverbindungen zum Telekomm...

Страница 97: ...detailed front panel LEDs located behind the front cover Figure 4 3 Detailed Front Panel LEDs TX Data Out GREEN On Data Leaving Port SPACE Off Data Leaving Port MARK RX Data In RED On Data Entering Port SPACE Off Data Entering Port MARK STAT Status Red On Fatal Report or WDT Off Normal Operation Flashing Slow Software Download in Progress PWR Status Power On GREEN Power is on and all DC Voltages a...

Страница 98: ...th is disrupted refer to the FT1 FE1 interface statistics for more information on the problem OFF Normal operation exists Stage when this indicates 1 Power PWR LED turns on GREEN Vanguard is receiving power 2 PWR LED remains on and the Status STAT LED blinks RED Diagnostics are starting 3 PWR LED blinks Diagnostics are executed 4 PWR LED remains on and the STAT LED blinks Indicates software is bei...

Страница 99: ...net session from your PC to the target node using and IP address configured in that node Connect to the CTP by entering atds0 CR after the Vanguard 34x outputs the OK prompt on your Telnet terminal window CTP Access Using Remote X 25 or Frame Relay Network If the Vanguard 34x is operating in an X 25 network or if Frame Relay Annex G is used to connect with other VanguardMS Network Access Product n...

Страница 100: ...l Vanguard s CTP 2 Select the Diagnostics Menu and then select Telnet 3 Type any IP address that is configured in the target Vanguard Using SoTCP If the target Vanguard device has been previously configured for a particular network connection using SoTCP and AT PAD you can access the CTP using Frame Relay Bypass Use these steps to establish an SoTCP connection to the target Vanguard s CTP using Fr...

Страница 101: ...ility If you do not have serial numbers for the Applications Ware package contact your distributor VanguardMS sales or service Operating Software The operating software is compressed in FLASH and loaded into the SDRAM for execution There are a variety of operating software feature sets available for the Vanguard 34x For feature information on the operating software available for your device refer ...

Страница 102: ...ing file naming formats Filename Description XXp01 xrc where XX identifies the software release number applicable to that image p identifies the Vanguard V340 product equipped with 8MB SDRAM Units that have 4MB SDRAM are identified by the letter k 01 identifies the number of the image created for any specific software release xrc identifies the file as a software image XXp01 zip is a compressed ve...

Страница 103: ...Megabyte SDRAM DIMM expandable to 32 Megabytes optional Data Compression and Encryption SIMM optional 2 optional daughtercard ports 1 configurable Universal Serial Interface port 340 Enhanced Hardware The Vanguard 340 Enhanced product features the following 50 Mhz MPC860P PowerPC processor 10 100 Base T Ethernet Async RJ 45 connector Control Terminal Port CTP 8 Megabyte of Non Volatile FLASH on bo...

Страница 104: ...are Release Notice accompanying your Vanguard unit for more information on the software license upgrades available for the Vanguard 340 and 340 Enhanced Environmental The following environmental conditions are required Operating temperature 32 to 104 F maximum 0 to 40 C maximum Storage temperature 40 to 158 F 40 to 70 C Relative humidity 5 to 90 non condensing ...

Страница 105: ...wer Supply Description The Vanguard 340 and 340 Enhanced use a different external power supply The external power supply for the Vanguard 340 Enhanced cannot be used on a Vanguard 340 Vanguard 340 is powered by a switch mode power supply with 50 watts maximum output power Vanguard 340 Enhanced is powered by a switch mode power supply with 35 watts maximum output power Safety Vanguard 340 and 340 E...

Страница 106: ......

Страница 107: ...B 1 Appendix B Software License and Regulatory Information Overview Introduction This appendix provides information about the following FCC Part 68 and Telephone Company Procedures and Requirements Product Declarations and Regulatory Information ...

Страница 108: ... connector number Service code Facility interface codes Troubleshooting Your Connection If any of your equipment is not operating correctly immediately remove it from the telephone line before damaging the network If the telephone company is aware of the problem they may temporarily disconnect your service Whenever possible the telephone company notifies you in advance of the disconnection If adva...

Страница 109: ...lephone company may make changes in their equipment operations or procedures If these changes affect your equipment or service the telephone company will provide written notice so you can make the necessary changes to maintain uninterrupted service Contact your telephone company if you have any questions about your telephone line In some circumstances the telephone company may ask you for informat...

Страница 110: ...uipements sont désignés comme TBTS Pour garantir la conformité à la norme EN 60950 n interconnecte ces ports qu avec des ports du même type sur des autres matériels Anschlusse die mit anderen Geraten verbindet werden konnen sind als SELV beschrieben Um Konformitat mit EN 60950 zu versichern sichern Sie es daß diese Anschlusse nur mit den des selben Type auf anderen Geraten verbindet werden CE Mark...

Страница 111: ...ten en andere relevante voorwaarden van EG richtlijn 1999 5 EG Vaatimustenmukaisuusvakuutus VanguardMS vakuuttaa täten että Vanguard Router on direktiivin 1999 5 EC keskeisten vaatimusten ja sen muiden tätä koskevien säännösten mukainen Déclaration de conformité Par la présente VanguardMS déclare que ce routeur Vanguard est conforme aux conditions essentielles et à toute autre modalité pertinente ...

Страница 112: ...és da presente a VanguardMS declara que este encaminhador Vanguard se encontra em conformidade com os requisitos essenciais e outras disposições relevantes da Directiva 1999 5 CE Declaración de conformidad Por la presente declaración VanguardMS declara que este encaminador Vanguard cumple los requisitos esenciales y otras cláusulas importantes de la directiva 1999 5 CE Överensstämmelseförklaring V...

Страница 113: ...by the user to this equipment or equipment malfunctions could give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution can be particularly important in rura...

Страница 114: ......

Страница 115: ...VENUE OR PROFITS OR FOR ANY OTHER SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES EVEN IF THEY WERE FORESEEABLE OR YOU HAVE INFORMED VANGUARD MANAGED SOLUTIONS OF THEIR POTENTIAL Some states do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied warranties or limitations on the duration of implied warranties so the above limitations or exclusions may n...

Страница 116: ......

Страница 117: ... additional concerns in case of failure about missing parts or to return equipment contact your nearest VanguardMS representative Expiration of Lease To return equipment upon expiration of a lease agreement contact the VanguardMS Customer Operations Center at 800 544 0062 for return authorization and instructions You will be asked to provide the following information Product name and description S...

Страница 118: ...turn Product name and description Serial number Failure symptoms Packaging Guidelines for Equipment Return Data communications equipment or parts that are to be returned to VanguardMS for any reason must be properly packaged to prevent damage in shipment and handling If the original packing material and shipping container are available reuse these items to return equipment If these items are not a...

Страница 119: ...1 22 Connectors 2 12 Control Terminal Port CTP accessing 4 7 CTP access 4 7 description 1 5 D Data Compression SIMM 2 7 Daughtercard 2 Port Voice FXS 2 10 2 11 4 Port Voice FXO 2 11 4 Port Voice FXS 2 11 56 K DSU CSU 2 14 compatibility 2 9 DIM 2 15 Dual E M 2 12 Dual Slots 1 5 FT1 FE1 2 11 G SHDSL 2 16 ISDN BRI Voice 2 14 ISDN BRI ST 2 13 2 14 ISDN BRI U 2 13 RemoteVU 2 12 V 34 Modem 2 15 V 90 Mod...

Страница 120: ...tor Pinout 3 17 power source 3 4 Power requirements A 3 Powering on 4 2 Powerup diagnostics 4 2 4 5 power up 4 2 Product Declarations B 4 R Rear Panel 2 3 3 12 Regulatory Information B 4 Canadian requirements B 7 Industry Canada B 7 RemoteVU Daughtercard 2 12 Remove Replace components 3 22 motherboard 3 24 Resetting the Device 4 2 S Safety specifications A 3 Serial Interface 2 7 about 3 8 interfac...

Страница 121: ... panel 3 12 configuration 3 12 description 1 2 enclosure 2 2 features 1 4 front panel 2 2 installation 3 6 motherboard 2 4 2 5 operating software 1 7 rear panel 2 3 resetting the device 4 2 serial interface 2 7 serial number 2 3 shipment contents 3 2 specifications A 1 Vanguide CD ROM viiix Video RemoteVU Daughtercard 2 12 Virtual Private Network Description 1 9 Voice FXS FXO Daughtercard 2 10 ...

Отзывы: