7.1 Peripheral Equipment Mounts
7-2
HW0482170
HW0482170
Fig. 14 Installing Peripheral Equipment Mounts
55
75
15
40
70
50
dia.
Peripheral
equipment
is
to
be
mounted
within
this
range.
50
65
165
80
104
94
Units:
mm
55
75
15
40
Tapped
hole
M6
(2
holes)
Tapped
hole
M6
(2
holes)
(depth:
12
mm)
(pitch:
1.0)
(depth:
12
mm)
(pitch:
1.0)
Tapped
hole
M6
(2
holes)
(depth:
12
mm)
(pitch:
1.0)
100
15
65
85
Tapped
hole
M8
(2
holes)
(depth:
16
mm)
(pitch:
1.25)
65
50
94
104
100
15
65
85
165
80
Tapped
hole
M10
(4
holes)
Tapped
hole
M10
(4
holes)
(depth:
20
mm)
(pitch:
1.5)
(depth:
20
mm)
(pitch:
1.5)
Tapped
hole
M10
(4
holes)
(depth:
20
mm)
(pitch:
1.5)
Содержание EA1900N