9.1 Parameter settings for MMA welding
Select the STICK method using button (
3
). Current is adjusted with knob (
4
). Welding current is
limited to 160 A. The VRD (Voltage Reduction Device) function is activated with the button (
6
),
which increases the safety of the welder especially when welding in places with an increased
risk of electric shock. The VRD function reduces the idle mode voltage from the level of
60 V to 12 V. The active VRD function makes it difficult to ignite the arc, however, therefore user
needs to scratch the electrode several times. No other welding functions are available.
10. Device defects during operation
Attention:
The device may only be repaired by authorized personnel!!
10.1 Errors occurring during MIG/MAG welding,
ATTENTION:
Make sure that MIG welding method is selected with switch (3).
Fault
Potential cause
Recommendations
Arc unstable
Wire speed too high / too low
Set the correct speed according
to the wire diameter and welding
current
Poor contact of the mass clamp
with the welded workpiece
Check the clamp and secure it
again
Wrong or worn contact tip
Replace the tip with the correct one
Incorrect gas flow
Set the correct flow
Clogged wire liner
Clean with compressed air or
replace
Wire feeding incorrect
Check wire feed unit rolls
and pressure force
Power source failure
Contact technical support
Too much spatter during welding
Too high wire feeding speed
Lower the speed
Too high welding current
Lower welding current
Welded workpiece dirty
Clean the welded workpiece