The device has an IP21S protection rating for housing and may be exposed to atmospheric 

fallout and is capable of operating outdoors.

 

- do not use the device for welding the tanks previously used for storing flammable substances.

 

 

 

 

ATTENTION

 

GASES AND FUMES

 

Using  MIG  /  MAG,  TIG  and  MMA  techniques  produces  harmful  gases  and  fumes  containing 
ozone  and  hydrogen  as  well  as  oxides  or  metal  particles.  Therefore,  the  welding  work  station 
should  be  fitted  with  very  good  ventilation  (dust  and  smoke  extraction)  or  should  be  placed  in 
airy location. Metal surfaces intended for welding should be free from chemical contamination, 
especially  degreasers  (solvents)  that  decompose  during  welding  process  and  produce  toxic 
gases.  Welding  of  galvanized,  cadmium-coated  or  chromium-plated  parts  is  permitted  only 
when a suction and filtering device is fitted, and with introduction of fresh air to the welding work 
station.

 

 

RADIATION

 

Ultraviolet emission radiated when welding is harmful to eyesight and skin. Therefore a welding 
mask with protective filters is required. Welding work station should meet certain requirements 
and include:

 

• adequate lighting system,

 

• fixed or movable protection screens, governing bystanders against radiation 

effects 

(depending on requirements),

 

• placed in a room with appropriate wall colour (absorption of UV radiation)

 

 

FIRE PROTECTION

 

Welding  work  station  should  be  located  at  a  safe  distance  from  flammable  materials  placed 
especially  on  the  floor  or  walls.  All  flammable  materials  need  fire  protection  against  hot  metal 
drops. It is recommended to fit the work station with fire blankets and fire extinguishers.

 

 

PROTECTION AGAINST ELECTRIC SHOCK

 

It  is  unacceptable

  to  connect  the  device  to  an  improper  installation  or  to  an  installation  with 

unverified zeroing efficiency. It is prohibited to use of device with shields removed or remove the 
external shields while the device is connected to electric network. It is not allowed to work on a 
suspended  device  (e.g.  using  a  crane  or  a  gantry).  Only  authorized  persons  should  perform 
maintenance and repair works keeping it in compliance with the safety conditions applicable to 
renovation equipment.

 

 

2. Maintenance

 

ATTENTION

:  In  order  to  carry  out  any  repair  or  maintenance  activity,  it  is  recommended  to 

contact  your  nearest  technical  support  of 

RYWAL-RHC

  (a  list  of  authorized  service  shops  is 

available on the last page of the manual).

 

 

In  the  event  of  noticing  any  damage,  the  welder  should  stop  working,  disconnect  the  device 
from power supply and report it to direct supervisor or appropriate service

 

- technical support of 

RYWAL-RHC

.

 

Содержание Fanmig J5 MOST

Страница 1: ...ing machine Fanmig J5 MOST Attention A copy of this manual should be located in the place of device use and should always remain available to the operator Original manual Catalogue no Fanmig J5 51 00...

Страница 2: ...defrosting Information included on icons located on the device Use and maintenance of welding equipment may be dangerous The user must observe health and safety rules and regulations Welding and cutti...

Страница 3: ...and normal operation are possible only after reading the carefully reading following manual Welding requires meeting the requirements for electric arc welding regulations and complying with fire regu...

Страница 4: ...protection screens governing bystanders against radiation effects depending on requirements placed in a room with appropriate wall colour absorption of UV radiation FIRE PROTECTION Welding work stati...

Страница 5: ...d equipment shall be borne by the owner This results in the obligation to perform periodic and post repair checks and inspections of equipment Periodic tests are carried out at least once a year legal...

Страница 6: ...MIG MAG 200A 24V 40 130A 20 5V 100 MMA 160A 26 4V 40 100A 24 0V 100 Wire feeding speed m min 2 11 5 Insulation class F Protection class IP21S Wire feeder type 2 roller Dimensions mm 440x180x350 Weigh...

Страница 7: ...MOST 7 5 Device construction Fanmig J5 Pos Presentation 1 ON OFF switch 2 Power cord with plug 3 Gas connection 4 Control panel 5 Euro socket for MIG MAG welding torch 6 Socket 7 Socket 8 Wire feeder...

Страница 8: ...s between welding parameters voltage in volts and wire feed speed in m min arc length correction within 5 V from factory settings IND Inductance in the range of 10 from factory settings DIA Steel wire...

Страница 9: ...eding without opening the gas flow and not applying current to the contact tip The button is not active in MMA and LiftTIG welding 6 6 Mode switch VRD ON 2 stroke 4 stroke 6 VRD ON only for the MMA me...

Страница 10: ...short length of wire from the spool align the end of the wire cut with pliers 57 00 004707 insert the end into the guide and then onto the feed roll the upper pressure mechanism raised Than guide the...

Страница 11: ...rch operating mode 2 step or 4 step Press the switch 2 to select the DIA wire diameter 0 8 mm or 1 0 mm The selection is made with the knob 4 and confirmed by a press You can also correct the arc leng...

Страница 12: ...g over e g chained to a wall Trolleys can be used to transport the device together with the cylinder and accessories e g WUS 150 HD cat no 50 03 003942 Having the cylinder placed and gas hose connecte...

Страница 13: ...argon flow on torch handle the arc is ignited by gently scratching the tungsten electrode tip on the material and then raising it up by 2 3 mm Welding ends with breaking the arc in similar way to MMA...

Страница 14: ...eration Attention The device may only be repaired by authorized personnel 10 1 Errors occurring during MIG MAG welding ATTENTION Make sure that MIG welding method is selected with switch 3 Fault Poten...

Страница 15: ...witch 3 Fault Potential cause Recomme ndations Excessive splatter Arc too long Too high welding current Adjust the welding current to the electrode diameter Crater at the end of the weld Too quick det...

Страница 16: ...ial or welding wire Welding speed too high and gas shield missing Blowing the gas shielding Water around the weld Clean and dry the material before welding Guide the torch according to the welding tec...

Страница 17: ...User Manual rev 1 1 of 16 12 2019 EN Original manual Fanmig J5 MOST 17 11 Fanmig J5 Wiring diagram...

Страница 18: ...Semi Automatic Welding Machine Fanmig J5 MOST 5 The subject matter of this declaration mentioned above is in conformity with the relevant requirements of EU harmonization legislation Low Voltage Dire...

Страница 19: ...2012 19 EU WEEE II WEEE Waste Electrical and Electronic Equipment after decommissioning the device must be recycled by a specialized company Do not dispose of worn out welding equipment with domestic...

Страница 20: ......

Отзывы: