background image

User Manual

 

rev. 

1.1 of 16.12.2019

 EN

 

 

Original manual

 

Fanmig J5 MOST

 

-3-

 

 

 

 

 

 

Stop  your  work  immediately  after  finding  damage  to  the  power  cords.  Do  not 
touch  the  damaged  cords.  Prior  a  repair  or  maintenance  disconnect  the  device 
from power source. Never use the device with damaged power cords.

 

 

 

 

Keep a fire extinguisher close to the welding location. After finishing welding 
check work station against fire hazard.

 

 

 

 

Never try to fix a damaged gas reducer on your own. In case of malfunction 
replace the reducer to a fully functional one.

 

 

 
 
 
 
 

 

Electromagnetic interference.

 

The device may influence other devices sensitive to electromagnetic interference 
(robots, computers, etc.)

 

Always ensure that the devices within the welding work station are resistant to 
interference. 

 

In order to minimize interference it is recommended to use possibly shortest 
welding cables arranged in parallel.

 

Always work in a distance at least 100 m from other sensitive devices. Always 
make sure that the installation is grounded.

 

In case of interference with other devices, shield the cables or use appropriate 
filters.

 

 

INTRODUCTION

 

Commissioning  and  normal  operation  are  possible  only  after  reading  the  carefully  reading 
following manual. Welding requires meeting the requirements for electric arc welding regulations 
and  complying  with  fire  regulations.  Device  operator  should  be  equipped  with  appropriate 
personal protective equipment. It is necessary to use a set of personal protective equipment in 
accordance  with  according  to  provisions  of  the  Council  Directive  89/686/EEC.  Personal 
protective  equipment  includes:  welding  mask,  welding  gloves,  protective  apron,  leather  shoes, 
non-flammable welding clothing.

 

Despite  the  high  technical  standard  of  the  device,  the  personnel  should  demonstrate 
considerable  discipline in  terms  of  health and safety  requirements  that  protect  against  harmful 
and health hazardous factors resulting from welding technology.

 

 

OPERATING CONDITIONS

 

In order to ensure adequate service life and trouble-free operation:

 

- do not place or use this device on an inclined surface (of more than 15º),

 

- do not use the device for pipe defrosting,

 

- the device needs to be located in a place with free air circulation (with no restrictions of the air 

flow  to  and  from  the  fan).  When  connected  to  electrical  network  the  device  must  not  be 
covered (for example, with paper or cloth),

 

-  minimize  the  amount  of  dirt  and  dust  that  can  get  into  the  device,

Содержание Fanmig J5 MOST

Страница 1: ...ing machine Fanmig J5 MOST Attention A copy of this manual should be located in the place of device use and should always remain available to the operator Original manual Catalogue no Fanmig J5 51 00...

Страница 2: ...defrosting Information included on icons located on the device Use and maintenance of welding equipment may be dangerous The user must observe health and safety rules and regulations Welding and cutti...

Страница 3: ...and normal operation are possible only after reading the carefully reading following manual Welding requires meeting the requirements for electric arc welding regulations and complying with fire regu...

Страница 4: ...protection screens governing bystanders against radiation effects depending on requirements placed in a room with appropriate wall colour absorption of UV radiation FIRE PROTECTION Welding work stati...

Страница 5: ...d equipment shall be borne by the owner This results in the obligation to perform periodic and post repair checks and inspections of equipment Periodic tests are carried out at least once a year legal...

Страница 6: ...MIG MAG 200A 24V 40 130A 20 5V 100 MMA 160A 26 4V 40 100A 24 0V 100 Wire feeding speed m min 2 11 5 Insulation class F Protection class IP21S Wire feeder type 2 roller Dimensions mm 440x180x350 Weigh...

Страница 7: ...MOST 7 5 Device construction Fanmig J5 Pos Presentation 1 ON OFF switch 2 Power cord with plug 3 Gas connection 4 Control panel 5 Euro socket for MIG MAG welding torch 6 Socket 7 Socket 8 Wire feeder...

Страница 8: ...s between welding parameters voltage in volts and wire feed speed in m min arc length correction within 5 V from factory settings IND Inductance in the range of 10 from factory settings DIA Steel wire...

Страница 9: ...eding without opening the gas flow and not applying current to the contact tip The button is not active in MMA and LiftTIG welding 6 6 Mode switch VRD ON 2 stroke 4 stroke 6 VRD ON only for the MMA me...

Страница 10: ...short length of wire from the spool align the end of the wire cut with pliers 57 00 004707 insert the end into the guide and then onto the feed roll the upper pressure mechanism raised Than guide the...

Страница 11: ...rch operating mode 2 step or 4 step Press the switch 2 to select the DIA wire diameter 0 8 mm or 1 0 mm The selection is made with the knob 4 and confirmed by a press You can also correct the arc leng...

Страница 12: ...g over e g chained to a wall Trolleys can be used to transport the device together with the cylinder and accessories e g WUS 150 HD cat no 50 03 003942 Having the cylinder placed and gas hose connecte...

Страница 13: ...argon flow on torch handle the arc is ignited by gently scratching the tungsten electrode tip on the material and then raising it up by 2 3 mm Welding ends with breaking the arc in similar way to MMA...

Страница 14: ...eration Attention The device may only be repaired by authorized personnel 10 1 Errors occurring during MIG MAG welding ATTENTION Make sure that MIG welding method is selected with switch 3 Fault Poten...

Страница 15: ...witch 3 Fault Potential cause Recomme ndations Excessive splatter Arc too long Too high welding current Adjust the welding current to the electrode diameter Crater at the end of the weld Too quick det...

Страница 16: ...ial or welding wire Welding speed too high and gas shield missing Blowing the gas shielding Water around the weld Clean and dry the material before welding Guide the torch according to the welding tec...

Страница 17: ...User Manual rev 1 1 of 16 12 2019 EN Original manual Fanmig J5 MOST 17 11 Fanmig J5 Wiring diagram...

Страница 18: ...Semi Automatic Welding Machine Fanmig J5 MOST 5 The subject matter of this declaration mentioned above is in conformity with the relevant requirements of EU harmonization legislation Low Voltage Dire...

Страница 19: ...2012 19 EU WEEE II WEEE Waste Electrical and Electronic Equipment after decommissioning the device must be recycled by a specialized company Do not dispose of worn out welding equipment with domestic...

Страница 20: ......

Отзывы: