User Manual
rev.
1.1 of 16.12.2019
EN
Original manual
Fanmig J5 MOST
-11-
7.6 Connection of ground cable
Connect the ground cable to the
7
(-) socket
on the
front of the device. The ground clamp
should be securely attached to the workpiece, preferably as close as possible to the welding
point.
Fig. 3 Preparation of the Fanmig device for MIG/MAG welding.
7.7 Parameter settings for MIG/MAG welding
Select the MIG method using button (
3
). Use switch (
6
) to select the welding torch operating
mode (2-step or 4-step). Press the switch (
2
) to select the DIA wire diameter: 0.8 mm or
1.0 mm, The selection is made with the knob (
4
) and confirmed by a press. You can also correct
the arc length or inductance to adapt arc to a welding position and in order to minimize spatter.
Welding current and wire feed speed are set synergistically. This means that changing one
parameter also adjusts the others necessary for stable welding.
When welding with self-shielding flux wire it may be necessary to change the polarization - see
wire manufacturer's recommendations. The way to change the polarity of the wire by placing the
wires is shown in the feeder sticker: