TECHNICAL DATA
REV
.0-12/19
D.C. WELDING
MAGIC WELD 200
Current range, continuous
20 - 200A
Open circuit voltage
70V
Duty cycle
200 A - 60%
A.C. GENERATION
230 V
110 V
Single-phase output (max)
3 kVA / 230 V / 13 A - 50 Hz / 60 Hz
2 kVA / 110 V / 18.2A - 50 Hz / 60 Hz
Single-phase output (continuous)
2.5 kVA / 230 V / 10.9 A - 50 Hz / 60 Hz
1.8 kVA / 110 V / 16.4 A - 50 Hz / 60 Hz
Cos
ϕ
0.8
0.8
ALTERNATOR
Self-excited, brushless
Type
permanent magnet
Insulating class
H
ENGINE
Mark / Model
HONDA / GX 270 (STAGE V)
Type / Cooling system
Gasoline 4-stroke OHV / Air
Cylinders / Displacement
1 / 270 cm
3
Output max
6.3 kW (8.5 HP)
Speed
3600 rpm
Fuel consumption (Welding 60%)
1.5 l/h
Engine oil capacity
1.1 l
Starter
recoil
GENERAL SPECIFICATIONS
Tank capacity
5.3 l
Running time (Welding 60%)
3.5 h
Protection
IP 23
*Dimensions / max. Lxlxh (mm)
630x490x540
*Weight
61 Kg
Acoustic power LwA (pressure LpA)
99 dB(A) (74 dB(A) @ 7 m)
*
Dimensions and weight are inclusive of all parts.
POWER
Declared power according to
ISO 3046-1 (temperature 25°C, 30% relative hummidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION
:
The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (L
W
A)
- Measure Unit dB(A)
:
it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp)
- Measure Unit dB(A)
:
it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(
L
W
A
)
of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)