![Morningstar TriStar MPPT 600V Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/morningstar/tristar-mppt-600v/tristar-mppt-600v_installation-and-operation-manual_1834372055.webp)
55
TriStar MPPT-600V-TR Operator’s Manual
5.0 Networking and Communication
5.1 Introduction
The TS-MPPT-600V-TR provides several communication options. The TS-MPPT-600V-TR uses
a proprietary protocol for the MeterBus
TM
network and the non-proprietary open standard
MODBUS
TM
and MODBUS TCP/IP
TM
protocols for RS-232, EIA-485, and ethernet networks.
Additionally, HTTP, SMTP, and SNMP are supported for web page, email, and network message
support. Morningstar’s MSView
TM
PC software provides system monitoring and logging
capabilities via RS-232, EIA-485, and ethernet. MSView
TM
PC software is available for free on
our website at:
http://www.morningstarcorp.com.
Further, hardware and third party software that supports the MODBUS
TM
protocol can also be
used to communicate with a TS-MPPT-600V-TR.
Multiple communication ports can be used simultaneously. For example, a TS-MPPT-600V-TR
may be connected to a MeterBus
TM
network for on-site system metering, connected to the
internet for remote monitoring, and connected to an EIA-485 network to bridge data from other
controllers in the system to an internet connection. Note that the RS-232 and EIA-485
connections share hardware and therefore cannot be used simultaneously.
Table 5-1 below provides a summary of supported features for each communication interface.
MeterBus
RS-232
EIA-485
Ethernet
Display system/network data on a TriStar meter
●
Connect a TSMPPT to a Relay Driver or other MS Accessory
●
Collect data from multiple TSMPPT HV controllers on a network
●
●
●
View and log data with MSView
TM
PC Software
●
●
●
View logged data stored in the TS-MPPT-600V-TR internal memory
●
●
●
●
Update TS-MPPT-600V-TR firmware
●
Program custom settings
●
●
●
View data in a web browser
●
Email notification
●
Text Message Alerts
●
SNMP Alerts
●
Table 5-1. Communication summary