TriStar MPPT-600V-TR Operator's Manual
Installation Safety Precautions
WARNING:
This unit is not provided with a GFDI device. This charge controller must be used with an
external GFDI device as required by the Article 690 of the National Electrical Code for
the installation location.
•
Mount the TS-MPPT-600V-TR indoors. Prevent exposure to the elements and do not allow
water to enter the controller.
•
Install the TS-MPPT-600V-TR in a location that prevents casual contact. The
TS-MPPT-600V-TR heatsink can become very hot during operation.
•
Use insulated tools when working with batteries.
•
Avoid wearing jewelry during installation.
•
The battery bank must be comprised of batteries of same type, make, and age.
•
Do not smoke in the vicinity of the battery bank.
•
Power connections must remain tight to avoid excessive heating from a loose connection.
•
Use properly sized conductors and circuit interrupters.
• The grounding terminal is located in the wiring compartment and is identified by the sym
-
bol below.
Ground Symbol
•
This charge controller is to be connected to DC circuits only. These DC connections are
identified by the symbol below.
Direct Current Symbol
The TS-MPPT-600V-TR controller must be installed by a qualified technician in accordance with
electrical regulations of the country where the product is installed.
A means of disconnecting all power supply poles must be provided. These disconnects must
be incorporated in the fixed wiring. Using the TS-MPPT-600V-TR ground terminal (in the wiring
compartment), a permanent and reliable means to the earth ground must be established.
The grounding conductor must be secured against any accidental detatchment.
The knock-outs in the TS-MPPT-600V-TR wiring compartment must protect wires with conduit or
rings.