![Morningstar TriStar MPPT 600V Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/morningstar/tristar-mppt-600v/tristar-mppt-600v_installation-and-operation-manual_1834372035.webp)
35
TriStar MPPT-600V-TR Operator's Manual
Float Stage - When the battery is fully charged, the charging voltage will be reduced to the Float
voltage setting.
Equalize Stage - During an equalization cycle, the charging voltage will be held constant at the
specified voltage setting.
Equalize Interval - The number of days between equalization charges when the controller is
configured for automatic equalizations (settings switch 7).
Switch 7: Battery Equalization
Choose between manual and automatic battery equalization charging. In the manual equaliza-
tion setting, an equalization will only occur when manually started with the pushbutton or when
requested from the equalize menu on the TriStar meter. Automatic equalization will occur accord-
ing to the battery program specified by settings switches 4, 5, & 6 in the previous step.
In both settings (auto and manual), the push-button can be used to start and stop battery equal-
ization. If the selected battery charging setting does not have an equalization stage, an
equalization will never occur, even if requested manually.
Equalize
Switch 7
manual
OFF
automatic
ON