MORNINGSTAR CORPORATION
MORNINGSTAR CORPORATION
SPECIFICATION SUMMARY
DIMENSIONS [millimeters (inches)]
TABLE OF CONTENTS
1.0 Important Safety Instructions .................................................................................1
2.0 General Information .... ..........................................................................................4
2.1 Overview ...........................................................................................................................4
2.2 Versions and Ratings........................................... .................................................................4
2.3 Exterior Features ..............................................................................................................5
2.4 Interior Features ...............................................................................................................7
2.5 Optional Accessories......................................................................................................9
3.0 Installation ............................................................................................................10
3.1 General Installation Notes ...............................................................................................10
3.2 Mounting ........................................................................................................................11
3.3 Over-current Protection Devices and Disconnect Switches..............................................13
3.4 Wiring .............................................................................................................................15
3.4.1 Battery Sense Wires..........................................................................................16
3.4.2 Remote Temperature Sensor with Ferrite Choke............................................18
3.4.3 Grounding and Ground-fault Interruption.......................................................19
3.4.4 Battery Connections.........................................................................................20
3.4.5 Solar Connections.............................................................................................21
3.4.6 Load Connections.............................................................................................21
3.4.7 Ready Block Installation.....................................................................................22
3.4.8 Final Connnections...........................................................................................24
3.4.9 Power Up and Verify System Operation...........................................................24
3.4.10 Power Down.....................................................................................................25
3.5 Commissioning / Initial Configuration..........................................................................25
3.5.1 Methodology.......................................................................................................25
3.5.2 Commissioning Menu........................................................................................25
3.5.3 Stand-alone commissioning Settings.................................................................25
(Cont.)
222.2(8.75)
360.40
(14.19)
201.6(7.94)
348.40
(13.72)
6.00
(0.24)
O5.5(0.22)
O 5.5 (0.22)
O 10.2 ( 0.4)
170.2(6.7)
GS-MPPT-60 GS-MPPT-80 GS-MPPT-100
Nominal Battery
Voltage
12-24-48V
12-24-48V
12-24-48V
Maximum PV Open-
circuit Voltage
1
200V
200V
200V
Nominal Maximum
Output Power
800-1600-
3200W
1075-2150-
4300W
1350-2700-
5400W
Maximum
Recommended PV
Input Power
2
1200-2400-
4800W
1600-3200-
6400W
2000-4000-
8000W
Maximum Charging
Current
3
60A
80A
100A
Rated Load Current
30A
30A
30A
1
Array voltage should never exceed this limit
2
150% of Nominal Maximum Output Power
3
Maximum includes battery current plus any load current