Morgana DocuMaster MFC - Service Manual
185
4. Service Procedures - The MFC Maintenance Schedule
4
4.14.5
The Friction Feed Bin Maintenance Schedule
Use the list that follows to do a maintenance inspection on the friction feed bin module.
9
Do a check that the feed bin emitter/sensor low range is set correctly.
10
Do a check that the feed head separation adjuster is correctly calibrated.
11
Do a check that the paper stop fingers are not worn (replace the paper stop
fingers if necessary).
12
Clean the tray height sensor and tray loaded sensor (use filtered compressed
air or a soft paint brush).
13
Do a check that there are no air leaks.
14
Clean the vacuum filters (replace the vacuum filters if necessary).
15
Do a check that the trays lift and drop correctly.
16
Do a check that the tray sidelays operate correctly.
17
Do a check that all the conveyor wheels are in satisfactory condition (replace
the conveyor wheels if necessary).
(See Section 4.8.11)
(See Section 4.8.12)
18
Select Cleaning Mode and clean the conveyor wheels.
19
Do a check that all the feed bin controls work correctly.
20
Do a check that all screws are tight.
21
Clean the suction feed bin.
Step
Action
Reference
Step
Action
Reference
1
Do a check that all wires and connectors are not damaged or lose.
2
Do a check that the drive chains, sprockets and tensioner bushes are not
worn (replace both the drive chain and sprockets if the sprockets are worn).
3
Select Cleaning Mode and lubricate all of the drive chains and sprockets
(Molykote MKLn chain grease is recommended).
4
Do a check that all the nylon gears are in a satisfactory condition.
5
Do a continuity test on all of the earth plates, tabs and shafts.
6
Do a check that the feed clutches operate correctly.
7
Do a check that the feed wheels are in a satisfactory condition (replace the
feed wheels if necessary).
8
Do a check that the separator pads are in a satisfactory condition (replace
the separators if necessary).
9
Clean the separator pads.
10
Clean the feed bin emitter/sensor assembly.
11
Do a check that the feed bin emitter/sensor low range is set correctly.
12
Clean the tray loaded sensor (use filtered compressed air or a soft paint
brush).
13
Do a check that there are no air leaks.
14
Do a check that all springs are in a satisfactory condition.
15
Do a check that the tray lifts and drops correctly.
16
Do a check that the tray sidelays operate correctly.
17
Do a check that all the conveyor wheels are in satisfactory condition (replace
the conveyor wheels if necessary).
(See Section 4.9.6)
(See Section 4.9.7)
18
Select Cleaning Mode and clean the conveyor wheels.
Содержание DocuMaster MFC
Страница 8: ...CONTENTS vi Morgana DocuMaster MFC Service Manual ...
Страница 9: ...Morgana DocuMaster MFC Service Manual 1 1 SECTION 1 Introduction ...
Страница 27: ...Morgana DocuMaster MFC Service Manual 19 2 SECTION 2 Error Conditions ...
Страница 43: ...Morgana DocuMaster MFC Service Manual 35 3 SECTION 3 Output Quality Problems ...
Страница 46: ...3 Output Quality Problems Crease Quality 38 Morgana DocuMaster MFC Service Manual ...
Страница 47: ...Morgana DocuMaster MFC Service Manual 39 4 SECTION 4 Service Procedures ...
Страница 196: ...4 Service Procedures The MFC Maintenance Schedule 188 Morgana DocuMaster MFC Service Manual ...
Страница 197: ...Morgana DocuMaster MFC Service Manual 189 5 SECTION 5 Parts Lists ...
Страница 199: ...Morgana DocuMaster MFC Service Manual 191 6 SECTION 6 General Procedures ...
Страница 220: ...6 General Procedures The MFC Machine Configuration Wizard Description 212 Morgana DocuMaster MFC Service Manual ...
Страница 221: ...Morgana DocuMaster MFC Service Manual 213 7 SECTION 7 Electrical and Control System ...
Страница 258: ...7 Electrical and Control System PC Configuration Problems 250 Morgana DocuMaster MFC Service Manual ...
Страница 259: ...Morgana DocuMaster MFC Service Manual 251 8 SECTION 8 Installation Manual ...
Страница 266: ...8 Installation Manual Install the MFC 258 Morgana DocuMaster MFC Service Manual ...
Страница 267: ......