Here you have the active alarms, press ALARM RESET to reset the resettable alarms. With
this icon
you access the window for alarms record.
N°
Warnings
Description
A01
Air pressure insufficient
Air pressure fault to the machine. Verify that the
manometer at the entry is at 6 bar or that the compressor
is suitable
A02
Emergency activated
The emergency stop button is pressed or one of the doors
is open.
A03 Error movement carriage
A04
Allarm inverter
Reset the alarm if it does not reset Reboot the machine
waiting for 2min. If the problem persists, contact technical
support.
A05
Error relay press
Reset the alarm if the problem persists, contact technical
support.
A06
Error movement press
The press has not achieved the position in the specified
time. Check it’s movement.
A07
Error relay heating
Reset the alarm if the problem persists, contact technical
support.
A08 Error milling station supply
Check the fuse FU13.01
A09
Cleaner present
At shutdown of the machine the head cleaning has been
made with the automatic cycle of the cleaner. Use the
loading glue cycle, load the glue. The machine with this
alarm does not work.
A10
Temperatures not OK
The nozzle or the premelter are not within the tolerances
set. (+5 ° C -2 ° C)
A11
Execute preset
The carriage or the nipping station need to perform preset.
Press before the icon of the presets, in main page, then
the two front buttons.
A12
Alarm hight temperature
Wait for 5 minutes. If after that time the temperature has
dropped, making cycle cleaner and switch off the machine.
Call technical support.
A13 Emergency button pressed
A14 Rear door opened
A15 Upper door opened
A16 Open clamp
A17 Close clamp