Operator Manual
DigiBook 150
27
Rev. 1.00-C
10
POWER ON
1) Be sure that the machine is pneumatically fed in the proper way
2) Turn on the machine turning the main switch
3) Open the valve you have on the premelter
4) Close the inspection panel on the top side
On display you will have:
Put the cover
Machine with cleaner
Machine not in temperature
Close the clamp
5) Press on display the icon bottom left to make the machine preset,
Press together the two buttons placed on the front part of the machine and hold them until
the end of the operation.
On display:
Machine with cleaner
Low temperature
6) When the temperature icon becomes green, press the button glue cleaner to load glue
7) Set the values, the length of the book and the glue stop (select the correct speed base of book
thickness)
8) Open the clamp at the thickness of the book you want to produce.
9) Open the head at the thickness of the book you want to produce.
10) Position the cover on the rear ledge of the press at the desired dimension.
11) Put the book in the clamp
a. put the cover
b. close the clamp
c. press together the two buttons placed on the front part of the machine and hold them
until the book arrives on the press
d. open the clamp
e. press together the two buttons placed on the front part of the machine and hold them
until the clamp return in the initial position
When the book is finished, remove it carefully.
Repeat all the operations of the point 11) to produce another book with the same dimensions
of the last one otherwise repeat the operations from point 7).
MyBinding.com
5500 NE Moore Court
Hillsboro, OR 97124
Toll Free: 1-800-944-4573
Local: 503-640-5920