A18 Cover not present
A19
CRITICAL TEMPERATURE You do cycle cleaner and switch off the machine. Call
technical support.
9. Described before.
10. Described before.
11. Icon, copies counter button, value not modifiable. When the icon is pressed, the window be-
low will appear.
You can select the kind of counter to be visualized on the main window. Press the corre-
spondent icon:
Total counter, not resettable.
Partial counter, resettable with a dedicated button.
Daily counter, resettable with a dedicated button.
When you have selected the kind of counter to be visualized on the main window, the icon
too changes in order to indicate it.
12. Icon, kind and dimension for the book button. When the icon is pressed, the window below
will appear.