38
MAINTENANCE
Before performing any maintenance procedures on the stove, follow
these precautions:
-
Wait until all parts of the stove are cold.
-
Wait until the ashes are completely off.
-
Make sure that the switch is in the
“
0
“
position.
-
Make sure that the power cable has been disconnected from the main
power supply.
PLEASE FOLLOW CAREFULLY THE FOLLOWING CLEANING IN-
STRUCTIONS!
MORETTI DESIGN IS NOT RESPONSIBLE FOR DAMAGE TO PEO-
PLE, ANIMALS OR THINGS CAUSED BY A NON
-
COMPLIANCE OF
THE FOLLOWING INDICATIONS.
In addition to the annual maintenance that must be carried out by author-
ized personnel, frequent cleaning procedures such as cleaning the burn-
er, emptying the ash drawer and cleaning the tube bundle should be
carried out.
Cleaning the burner
It is necessary to check if the burner is clean, that there are no combus-
tion residuals or if the air ports are not obstructed. All this to avoid that
the stove does not perform a poor combustion and to avoid overheating
which could cause damage to the stove
’
s painted surfaces or a failed
ignition of the flame.
While the hydro stove is in operation, residues can form in the burner
that must be removed before switching on again. The amount of ashes
left over in the burner depends on the type of pellet used, even the same
type of fuel from different bags of a the same brand can have different
outcomes when burnt.
Automatic burner cleaner
The PLUS CLEAN models are equipped with an automat-
ic burner cleaning system that activates during the first
phase of the ignition of the hydro stove. This function can
also be deactivated.
Emptying the ash drawer
The ash drawer is located inside the combustion cham-
ber. To access it, open the door, pull the drawer out and
then vacuum all ash deposits. For the PLUS CLEAN mod-
els, after consuming more than 80 bags of pellets, the
drawer can be simply emptied once. The bottom inspec-
tion compartment should be opened at least once a month in order to
vacuum all combustion residuals.
Cleaning the tube bundle
(see dedicated manual)
The wiper can be accessed through the handle and
moved according to the direction the arrows are pointing,
repeat the movement at least four times. During the oper-
ation you will notice a small amount of dust/ash falling
from the top of the combustion chamber. This operation must be per-
formed weekly.
Automatic heat exchanger cleaning
Some models are equipped with an automatic heat ex-
changer cleaning system (AUTO CLEAN) that is activated
during the first phase of the ignition of the hydro stove.
Cleaning the pellet tank
Monthly empty the pellet tank and vacuum all pellet dust residuals de-
posited at the bottom.
Cleaning the surfaces
Use a rag soaked with water for cleaning the painted metal surfaces.
The use of detergents or aggressive diluents can damage the stove
’
s
surfaces.
To ensure that the hydro stove always has an optimal combustion
and to avoid malfunctions, frequent cleaning operations must be
carried out. The frequency of these operations may vary according
to the time of use of the stove and quality of the pellets.
To avoid the water from freezing in the plumbing system, it is re-
commended to not disconnect the electrical power from the hydro
stove, if the water temperature drops to 5 °C, it automatically activa-
tes the pump to prevent freezing.
An overall accurate maintenance check up of the stove must be
carried out annually, and this must be performed by a qualified
technician. The stove must be kept in such a way as to preserve
conditions that ensure safety and efficiency.
WARRANTY
Warranty certification
Thanking you for choosing our product, MORETTI DESIGN invites you
to consult the user manual and to read the following warranty conditions
The manufacturer provides the customer with a 24 month period warran-
ty over the product, that starts from the date of purchase. In order to
enable the warranty, the client must send the
warranty certificate
to the
manufacturer headquarters, completely filled in, within 8 days from the
date of purchase and must keep a copy as proof of the purchase. It must
be sent to the following address:
Moretti Fire s.r.l. –
C.da Tesino, 50
-
63065 Ripatransone (AP) ITALY
or via e
-
mail:
A non received or incomplete warranty card voids the warranty.
Warranty conditions
The warranty is limited and only covers manufacturing defects.
Components not covered by warranty:
Ceramic glass
Door seals
Paint
Handles
Knobs
Majolica coating
Metal coating
Ignition resistance
Fuses
Combustion chamber parts
Wearing parts
The burner
The warranty does not cover damage caused by:
No first ignition and testing procedure carried out by a qualified technical
assistance centre (
expense on the client
’
s behalf
).
Installation performed by non professional personnel and not in compli-
ance with standard regulations or used in a different manner than that it
was designed for.
Electrical overloads caused by lightening or non conformed electrical
sockets.
Transport and tampering by unauthorized personnel.
The non application at least once a year of cleaning and routine mainte-
nance procedures of the product by a qualified authorized servic
(
expense on the client
’
s behalf
).
The use of cheap/poor quality fuel or any other material that can damage
the product.
Any damage caused by an improper installation and/or disattention of
the user.
The following interventions are not considered under warranty:
Interventions to adjust combustion parameters.
Interventions to repair damaged parts caused by poor maintenance.
EXCLUSION OF LIABILITY
Failure to comply with the operating conditions and decadence of the
warranty will result in the exclusion of the manufacturer from all liability
for any damage to the customer to animals and other people.