23
Change Code
: This function allows you to associate the radio display to
a specific stove so that only one remote can operate it (in this way, seve-
ral transmitting systems can be used in the same room). To change the
code and associate the radio display to a specific stove:
•
Select a new code in Change Code:
•
Turn off the main switch of the stove to prepare it for the code
changing operation.
•
Press and hold
SET
on the radio display and, at the same time,
turn on the main switch on the stove and check the outcome of
the operation.
If the words
Transfer Failed
appear, repeat the procedure and select a
different code.
Reset Cleaning
: Menu to reset the burn pot cleaning system
Screw Feeder Calibration
Menu to change the Screw Feeder operating time. There are 14 steps, 7
to increase and 7 to decrease; 0 corresponds to the default setting.
Attention
: to be used only by an authorized
MORETTI DESIGN
techni-
cian
Fan Calibration:
Menu to change the Combustion Air Fan speed. There are 14 steps, 7 to
increase and 7 to decrease; 0 corresponds to the default setting.
Attention
: to be used only by an authorized
MORETTI DESIGN
techni-
cian
Counters
Error List
WiKey Thermostat
Secondary Information
Radio Test
Change Code
Change
Code
999
1001
1002
1000
Power
Thermostats
Chrono
Information
Settings
Service
Error List
WiKey Thermostat
Secondary Information
Radio Test
Change Code
Reset Pulizia
OFF
OFF
Power
Thermostats
Chrono
Information
Settings
Service
WiKey Thermostat
Secondary Information
Radio Test
Change Code
Reset Cleaning
Screw Feeder Calibra-
Screw Feeder
Calibration
Max: 7
Set: 0
Min: -7
Automatic Power:
Menu to set power management in automatic mode.
Attention
: to be used only by an authorized
MORETTI DESIGN
techni-
cian
Load
This menu allows for the manual filling of the Screw Feeder.
The stove
must be
OFF
for this function to be activated.
If the Screw Feeder is
manually activated, then the Smoke Fan is also activated,
this
is necessary so that the Pressure Switch can close the
contact and the Screw Feeder can turn.
•
To scroll through the items of the menu, use the keys
to confirm the data press
SET
. To exit press
ESC
.
Loading Test
The Menu allows for the manual filling of the Screw
Feeder and allows you to check its correct operation.
•
To scroll through the items of the menu, use the keys
to confirm the data press
SET
. To exit press
ESC
.
System Menu
Menu to access the Secret Menu reserved for the authorised Technician.
Access to the page is PASSWORD protected.
Secondary Information
Radio Test
Change Code
Reset Cleaning
Screw Feeder Calibra-
tion
Fan Calibration
Fan Calibration
Max: 7
Set: 0
Min: -7
Radio Test
Change Code
Reset Cleaning
Screw Feeder Calibra-
tion
Fan calibration
Automatic Power
Automatic Power
ON
OFF
Load
Off
On
Radio Test
Change Code
Reset Cleaning
Screw Feeder Calibra-
tion
Fan Calibration
Automatic Power
Load
Loading Test
Off
On
Change Code
Reset Cleaning
Screw Feeder Calibration
Fan Calibration
Automatic Power
Load
Loading Test
PASSWORD?
- - - -
System Menu
EN