30
CONFIGURATION 11
The configuration shown in the figure is set.
Connections on the control unit
Connections on stove
’
s rear panel
Connections on the heating system
(the following schematic is only illustrative)
The system includes: the hydro stove Boiler Probe (
S
), the hydro stove Pump (
P1
), heating system Pump (
P3
), Puffer Probe(
S1
),Electrovalve (
P2
),
DHV probe (
S3
).
Electrovalve (P2)
Probe (S1)
Puffer/Boiler
Pump (P3)
17: towards heating system 18: towards domestic hot water
For models: ALADINO, ELEGANCE, CLESSIDRA, ERGONOMIC, COMPACT, VISION, SLOT VISION, DOLBY
Probe ACS (S3)
Probe Puffer/Boiler (S1)
For models: TECNIKA TURBO GLASS, TECNIKA FOR HOME, TURBO TOP, TURBO GLASS, PRESTIGE
Electrovalve (P2)
Pump (P3)
Probe ACS (S3)
17: towards heating system 18: towards domestic hot water
PUFFER
EN