25
PLUMBING CONFIGURATION
It is possible to integrate the hydro stove to one of the following hydraulic system configurations considered most suitable. To set the configuration, an
authorized technician
must be contacted.
CONFIGURATION 0
The configuration show in the figure is set. This is the standard setting.
If the domestic hot water kit is installed, it is not necessary to change the setting on the hydro stove.
Connections on the control unit
Connections on the heating system
(the following figure is only illustrative)
The system includes: the hydro stove Boiler Probe (
S1
), the hydro stove Pump (
P1
), Electrovalve of the kit (
P2
), Flow Switch of the kit (
FL
).
Electrovalve (P2)
Flow Switch (FL)
17: towards heating system 18: towards domestic hot water
Some models have connections on stove
’
s back, check the
scheme on page 36
-
37
EN